Skip to content

Roof cases with no oracle: 2024 gables and hips, a square two-cut with a fascia, a slope arrow stopping short (RE-199 follow-up) #885

Open

Description

@DrunkOnJava

RE-199 (#870) reads these roof cases, or draws them by rule, but no measured model has them:

  • Revit 2024 roofs with several defining edges (gables, hips): they take the same planes path as 2025's, gated by the record box. The only 2024 sloped roof measured is RE-56's 1:12 shed on the Autodesk tutorial house, which is local only and was not re-run.
  • A square two-cut rafter with a non-zero fascia depth: not drawn (the roof stays a level block), since none has been measured.
  • A slope arrow whose head stops short of the far edge: drawn with the plane running on past the head, as the PR describes Revit doing; not measured.

Oracle needed: small Revit 2024 and 2025 projects with these roofs and Revit's IFC export of each, licensed for redistribution. Measure would score them as it scores R2025_Models.zip (-f r2025=true, tools/re/roof_bodies_vs_ifc.py).

Activity

  1. added
    area:corpus
    area:geometry
    priority:P3
    type:research
    on Oct 21, 2026
  2. DrunkOnJava commented on Oct 21, 2026

    @DrunkOnJava
    OwnerAuthor

    Two measured observations from #870's Measure run 39602093604 (probe probe_re199_roof_edge_slopes on Autodesk's sample projects; neither file has a Revit export):

    • Revit 2024, rac_advanced: hips 165755, 167036 and 167158 each have four defining 15° edges whose f64 at +0x3b is 0.0, not −rise/run, so RE-56's 2024 rule (edge_slope) rejects every block and the hips stay level. The same edges in the rac_advanced 2025 save also carry 0.0 there, which RE-199's 2025 rule reads as the plate offset. So on 2024, +0x3b is not always −rise/run. RE-56's tutorial house is the one 2024 file measured where it is, and a 2024 rule that accepts both needs a 2024 file with Revit's export to settle it. Roof 142430's two defining edges have −15° angles and are not read on either release.
    • Revit 2025, rac_advanced: the same three hips are read as plumb cuts with no fascia, but each record box is exactly the hip's rise, 1.34775 ft over its 10.06 ft span (1.36137 over 10.16 for 167158), with no thickness added, so the plain body fails the record-box check and they stay level. Their roof type, or how Revit measures the box of such a hip, is unread.
  3. DrunkOnJava commented on Oct 24, 2026

    @DrunkOnJava
    OwnerAuthor

    Asked on #884 whether puzzbobb could add these cases to a T and U hip-roof model set, with Revit's IFC4 exports, since R2025_Models.zip is what measured the rest of RE-199. Nothing is written for these cases until an export of them is measured.

  4. 42 remaining items

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment