You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
rvt-rs writes IFC4, but some of the standard property sets it writes are IFC2X3's. They were taken from Revit's exports of the RE1 models, which are IFC2X3 (Coordination View 2.0), not IFC4 as RE-154 recorded; #820 corrected the same misreading for a room's floor finish. buildingSMART's IFC4 property set definitions (features/resources/IFC4/pset_definitions.csv of buildingSMART/ifc-gherkin-rules, the list its validation service checks property sets against) have none of these sets, and IFC reserves the Pset_ prefix for the sets it defines.
Written by rvt-rs
In IFC4
What Revit's IFC4 export writes (BIM4LCA office, as built)
Office values rvt-rs writes
Pset_QuantityTakeOff.Reference (the type's name), on every element with a type
no such set
Pset_EnvironmentalImpactIndicators.Reference, which IFC4 applies to every IfcElement (12,693 elements)
11,791
Pset_DistributionFlowElementCommon.Reference, on MEP elements
no such set
the entity's own set: Pset_PipeSegmentTypeCommon, Pset_SanitaryTerminalTypeCommon, Pset_LightFixtureTypeCommon and so on
358
Pset_FlowSegmentPipeSegment (Length, InvertElevation) and Pset_FlowSegmentDuctSegment (Length)
no such sets
Pset_PipeSegmentOccurrence.InvertElevation; the length in Qto_PipeSegmentBaseQuantities.Length
none (RE1 Mechanical and Plumbing: on 94 ducts and pipes)
Pset_ProductRequirements.Name, on storeys and spaces
no such set
none
201
Pset_AirSideSystemInformation.Name, on storeys and spaces
applies to spaces and zones, not storeys
none
201
What would close this:
Reference. Write the type's name in each IFC4 set that applies to the element's entity and declares Reference, from the table List every IFC4 property set of the entities rvt-rs writes, so a parameter named for any of them is written #817 generates. This replaces both Pset_QuantityTakeOff and Pset_DistributionFlowElementCommon. Revit's office export gives each class exactly those sets, apart from sets revit-ifc matches by a prefix of the entity's name (Pset_SpaceHeaterTypeCommon on spaces, Pset_StairFlightCommon on stairs, Pset_RampFlightCommon on ramps), which IFC4 does not apply to those entities.
Pipes and ducts. The invert in Pset_PipeSegmentOccurrence, the length in IFC4's base quantities.
Storeys and spaces. Neither name set.
A check that every Pset_ set rvt-rs writes is an IFC4 set, with that property, applying to the entity it is written on, so this cannot come back.
The comparisons with the RE1 models' IFC2X3 exports (tests/common_reference.rs, tests/reference_values.rs, tests/duct_fields.rs and tools/re/psets_vs_ifc.py) then compare each IFC2X3 set with the IFC4 one that holds the same value, as #820 does for the space coverings.
Related, separate: Revit's office export writes FireRating on 26 walls and 2 doors that carry no parameter named for it (RE-194). RE-77 reads a type's Fire Rating, but rvt-rs writes it only in its own set; whether those values are the types' Fire Rating is to be measured.
The RE1 comparisons map each IFC2X3 set to the IFC4 one that holds the same value, as #820 did for the space coverings. The type Fire Rating noted at the end also shipped in 0.6.0, in Pset_*Common.FireRating.
What this does not cover: quantity sets are not checked against definitions, and buildingSMART's own Validation Service has not been run on these exports.
Activity
16 remaining items
DrunkOnJava commentedon Oct 19, 2026
All four parts shipped in v0.6.0:
Reference(fix(ifc): an element's Reference is in IFC4's sets, and storeys and spaces lose IFC2X3's name sets (#822) #825): the type's name is inPset_EnvironmentalImpactIndicatorsand in each IFC4 set that applies to the element's entity and declaresReference, from List every IFC4 property set of the entities rvt-rs writes, so a parameter named for any of them is written #817's table.Pset_QuantityTakeOffandPset_DistributionFlowElementCommonare no longer written.Pset_PipeSegmentOccurrence, and a pipe's or duct's length is inQto_PipeSegmentBaseQuantitiesorQto_DuctSegmentBaseQuantities, written asIfcElementQuantity. A pipe fitting's nominal diameter moved to rvt-rs's ownRvtElementRecordGeometry(fix(ifc): a pipe fitting's nominal diameter is in rvt-rs's own set, not in Pset_PipeFittingTypeCommon, which IFC4 gives none (#822) #833), as IFC4 gives a fitting type no such property.mainat 23a9d76 (run 39273188597) it has no finding on any of the 89 exports: the reference models, both BIM4LCA office files, Autodesk's 58 samples and the 23 R2025 models. IfcOpenShell's schema validation has none either.The RE1 comparisons map each IFC2X3 set to the IFC4 one that holds the same value, as #820 did for the space coverings. The type Fire Rating noted at the end also shipped in 0.6.0, in
Pset_*Common.FireRating.What this does not cover: quantity sets are not checked against definitions, and buildingSMART's own Validation Service has not been run on these exports.
docs(re): the #822 move the right way round, the green runs, and RE-1…