Skip to content

RE-15-01: Wall instance recovery (evidence-only; schema-field Wall unsupported) #81

Closed

Description

@DrunkOnJava

Status (re-baselined 2026-08-29)

Not a converter-grade IFCWALL recall ticket. Current honesty:

  • Support matrix schema-field-wall = unsupported
  • Production-narrow path: version-gated 2023 ArcWall only
  • RE-19 / PR #142: no fail-closed schema-field Wall / 2024 ArcWall envelope on magnetar corpora

Honest next work

  1. Re-measure wall instance / IFC emission counts on Core Interior after Finding 1 strip (fix: strip checksum page trailers before inflate (#151) #160–docs(#151): Wave 2 evidence matrix + writer audit (support lane) #163)
  2. Evidence-only probes for schema-field Wall / 2024 ArcWall (may remain negative)
  3. Fail-closed diagnostics for unlinked wall ids — no invented recall marketing

Obsolete

Prior acceptance (walls_emitted >= 342, “v0.2.0 shipped 295/360”) — do not treat as current product claims.

Umbrella: #30.

Activity

  1. added
    area:elements
    area:partitions
    priority:P1
    type:feature
    on May 23, 2026
  2. DrunkOnJava commented on Aug 29, 2026

    @DrunkOnJava
    OwnerAuthor

    Re-baseline 2026-08-29: Keep open as research toward wall recovery, but the “v0.2.0 shipped 295/360 IFCWALL” framing is not current product honesty.

    Acceptance should become: evidence-backed wall instance recovery with fail-closed diagnostics — not IFC recall marketing targets. Umbrella: #30.

  3. changed the title [-]RE-15-01: Lift IFCWALL recall from 295/360 (82%) to >=95% on 2024_Core_Interior.rvt[/-] [+]RE-15-01: Wall instance recovery (evidence-only; schema-field Wall unsupported)[/+] on Aug 29, 2026
  4. added
    type:research
    and removed
    type:feature
    on Aug 29, 2026
  5. DrunkOnJava commented on Sep 19, 2026

    @DrunkOnJava
    OwnerAuthor

    Closed by 61c05d3 (#211). Re-measured after the Finding 1 strip, wall instance recovery on 2024_Core_Interior.rvt is 360 of 360 as an exact ElementId set, FP 0 and FN 0, via the partition element record's own BuiltInCategory rather than a schema-field or ArcWall envelope. RE-19's negatives are untouched and schema-field-wall remains unsupported in docs/support-matrix.json, so this closes the honest re-baseline without any recall claim on the carriers that stayed negative. Evidence: reports/element-framing/RE-21-partition-element-record-instance-rule.md.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:elementsarea:partitionspriority:P1type:research

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions