You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
MEP connectivity: ports and port-to-port connections (IfcDistributionPort, IfcRelConnectsPortToElement, IfcRelConnectsPorts) #528
Revit's own IFC export of an MEP model carries its connectivity: one IfcDistributionPort per connector (named InPort_<ElementId>_<index> or OutPort_<ElementId>_<index>, flow direction .SINK. or .SOURCE., with a placement), an IfcRelConnectsPortToElement for each, an IfcRelConnectsPorts for each connected pair, and an IfcSystem per system. On the MIT RE1 models:
model
ports
port-to-element
port-to-port
systems
RE1 Mechanical
150
150
73
5
RE1 Plumbing
260
260
126
8
RE1 Electrical
53
53
0
13
rvt-rs writes none of them: its MEP elements are unconnected shapes.
What is known
A pipe's or duct's connector entries (RE-131) hold each end's point, keyed by the element connected there and its connector index.
The curve's own object lists its connectors' references (its own ElementId, then the element joined at that connector and that element's connector index) about 1,060 bytes after its RbsCurveConnectorManager anchor (RE-134). This is seen, not decoded.
A fitting's, terminal's or piece of equipment's connectors are defined in its family, which rvt-rs does not read.
Acceptance
Ports and connections written for the elements whose connectors are decoded, with per-model counts against Revit's export on the reference pack (#407), the shortfall named. A connection is written only when both of its ports are, so a pipe joined to an undecoded fitting stays unconnected rather than dangling.
First part delivered in #550 (RE-138, reports/element-framing/RE-138-connector-pairs.md), measured on the runners (Measure run 36874925630).
Decoded: a duct's or pipe's object lists its joins as counted lists of two references after the RbsCurveConnectorManager anchor, in two blocks that store the curve's own connector index differently (inverted in the earlier). The lists reproduce 94.3% (50 of 53) of Revit's connections that involve a duct or pipe on RE1 Mechanical and 94.4% (102 of 108) on Plumbing.
Written:IfcDistributionPort, IfcRelConnectsPortToElement and IfcRelConnectsPorts for each join whose two elements are exported as distribution elements: 53 of 59 (89.8%) on Mechanical and 112 of 118 (94.9%) on Plumbing, every port tied to the element its name gives, IfcOpenShell's IFC4 schema validation of both files clean. Core Interior's export is byte-identical and no other scorer changes. tools/re/ports_vs_ifc.py is in every Measure run.
Still open on this issue:
Flow direction. Revit names ports InPort_/OutPort_ with .SINK./.SOURCE. (they agree on all 134 named ports of Mechanical), and the same connector index is In on some pipes and Out on others, so it is the system's flow, which the lists do not carry. rvt-rs writes .NOTDEFINED. and names ports Port_<ElementId>_<index>.
Connections that involve no duct or pipe (fitting to fitting, fitting to equipment): 14 of Mechanical's 73 and 8 of Plumbing's 126 involve no IfcFlowSegment. Only the lists of ducts and pipes have been looked at.
Equipment ports. Equipment rvt-rs writes as an IfcBuildingElementProxy gets none (IFC4 allows a port on a distribution element only); Revit's IFC2X3 export has 5 such ports on Mechanical.
The 6 connections not written on each model. On Mechanical, 3 are not read and 3 are to equipment written as a proxy; on Plumbing all 6 are not read. What is different about the lists of those is not established.
RE-141 (PR #552, reports/element-framing/RE-141-fitting-joins.md): the fittings' own joins are read, and the export writes ports for them, fitting to fitting included.
A fitting's own record holds only the ascending ids it refers to, with no connector index, and the pipes' connector managers lie outside the partition's leading record chain (all 63 on RE1 Plumbing and 31 on Mechanical). So the fittings' joins were not where RE-138's lead looked.
They are in the same list form as a pipe's (u32 2, then two references of element, connector index and u32 1), with the fitting first, found by the list alone anywhere in a partition. A fitting's list is written once and its own connector index is Revit's; a pipe's earlier copy is inverted.
Against Revit's own export of the RE1 models, every connection that involves a fitting is read on Plumbing (99 of 99, indexes exact) and 60 of 62 on Mechanical.
Export, head against main on the Measure workflow: of all of Revit's port-to-port connections, 66 of 73 are written on Mechanical (53 before) and 120 of 126 on Plumbing (112 before), none and one that Revit does not hold, no IfcOpenShell schema finding, and the other four RE1 and Core Interior outputs are byte-identical.
Still open on this issue: flow direction (the lists carry none), port placement, and the 7 and 6 connections left, which are joins to equipment written as a proxy (IFC4 allows no port on one) and joins no list read gives.
Where they are stored. Each system is one data object of class RbsHvacSystem, RbsPipingSystem or RbsElectricalSystem. Its members are the elements whose own data objects hold its id. HVAC and piping systems are named by the object's first ASCII string. Electrical systems are named by their circuit number, and an empty number is Revit's <unnamed>.
What rvt-rs writes. One IfcSystem per system, its members grouped by IfcRelAssignsToGroup and the building served by IfcRelServicesBuildings.
Tested against Revit's own export.tests/mep_systems.rs compares rvt-rs's export of RE1 Mechanical, Plumbing and Electrical with Revit's IFC4 export. All 26 systems match by name and member set (5, 8 and 13), CI run 37149305337: test re1_mep_systems_are_revits ... ok.
Ports and connections were written earlier (#550, #552). What is still open here is flow direction, the .SINK./.SOURCE. of each port, which RE-138 found no stored field for, and the few connections not yet read (7 of 73 on Mechanical, 6 of 126 on Plumbing).
Progress, 2026-10-04 (#673, B54): every duct and pipe now has a port at each end, joined or not. Revit's export writes connectors 0 and 1 of 92 of RE1's 94 ducts and pipes as ports whether or not anything is connected. rvt-rs wrote a port only for a join it read. With both end ports written, RE1 Plumbing has 255 ports against Revit's 260 (from 242) and every duct and pipe end port Revit writes on Mechanical and Plumbing is in the file, checked by tests/duct_and_pipe_ports.rs. One port is extra: port 0 of pipe 444124, which is joined to the tank Revit's export leaves out.
Next: a family instance's own connectors. Its FamilySymbol's native record lists them (m_arrConnectorData, each with an m_index), and its Family has a ConnectorDataCell per index with its domain. That is where Electrical's 53 ports and the open ports of fixtures and fittings should come from. It is being measured against Revit's port indices now.
The acceptance here is met. Ports and connections are written for every element whose connectors are decoded, measured against Revit's own exports (Measure run 39261416282):
all 73 of RE1 Mechanical's port-to-port connections and all 126 of Plumbing's, with none and 2 not in Revit's export;
What is left is tracked on its own: an HVAC or piping connector's flow direction, every port's SystemType and a connector's description in #834, and the ports' placement, which Revit's export gives each port and rvt-rs does not yet, in #847.
Activity
feat(ifc): ports and port-to-port connections for ducts and pipes (RE…
docs(elements): RE-138 report, changelog and support matrix entry; th…
fix(ifc): ports are tied only to distribution elements (RE-138) (#528)
docs(elements): RE-138 numbers after ports are tied only to distribut…
feat(ifc): RE-138 ports and port-to-port connections for ducts and pi…
DrunkOnJava commentedon Oct 1, 2026
First part delivered in #550 (RE-138,
reports/element-framing/RE-138-connector-pairs.md), measured on the runners (Measure run 36874925630).RbsCurveConnectorManageranchor, in two blocks that store the curve's own connector index differently (inverted in the earlier). The lists reproduce 94.3% (50 of 53) of Revit's connections that involve a duct or pipe on RE1 Mechanical and 94.4% (102 of 108) on Plumbing.IfcDistributionPort,IfcRelConnectsPortToElementandIfcRelConnectsPortsfor each join whose two elements are exported as distribution elements: 53 of 59 (89.8%) on Mechanical and 112 of 118 (94.9%) on Plumbing, every port tied to the element its name gives, IfcOpenShell's IFC4 schema validation of both files clean. Core Interior's export is byte-identical and no other scorer changes.tools/re/ports_vs_ifc.pyis in every Measure run.Still open on this issue:
InPort_/OutPort_with.SINK./.SOURCE.(they agree on all 134 named ports of Mechanical), and the same connector index is In on some pipes and Out on others, so it is the system's flow, which the lists do not carry. rvt-rs writes.NOTDEFINED.and names portsPort_<ElementId>_<index>.IfcFlowSegment. Only the lists of ducts and pipes have been looked at.IfcBuildingElementProxygets none (IFC4 allows a port on a distribution element only); Revit's IFC2X3 export has 5 such ports on Mechanical.ObjectPlacementyet.research(elements): RE-141 probe scans every partition for lists of t…
feat(ifc): RE-141 ports for the joins of duct and pipe fittings, fitt…
docs(research): RE-141 report, changelog and the support matrix row f…
DrunkOnJava commentedon Oct 1, 2026
RE-141 (PR #552,
reports/element-framing/RE-141-fitting-joins.md): the fittings' own joins are read, and the export writes ports for them, fitting to fitting included.u32 2, then two references of element, connector index andu32 1), with the fitting first, found by the list alone anywhere in a partition. A fitting's list is written once and its own connector index is Revit's; a pipe's earlier copy is inverted.Still open on this issue: flow direction (the lists carry none), port placement, and the 7 and 6 connections left, which are joins to equipment written as a proxy (IFC4 allows no port on one) and joins no list read gives.
feat(ifc): RE-141 ports for the joins of duct and pipe fittings (#528) (
10 remaining items
DrunkOnJava commentedon Oct 3, 2026
MEP systems landed in #631, from RE-162 (#632).
RbsHvacSystem,RbsPipingSystemorRbsElectricalSystem. Its members are the elements whose own data objects hold its id. HVAC and piping systems are named by the object's first ASCII string. Electrical systems are named by their circuit number, and an empty number is Revit's<unnamed>.IfcSystemper system, its members grouped byIfcRelAssignsToGroupand the building served byIfcRelServicesBuildings.tests/mep_systems.rscompares rvt-rs's export of RE1 Mechanical, Plumbing and Electrical with Revit's IFC4 export. All 26 systems match by name and member set (5, 8 and 13), CI run 37149305337:test re1_mep_systems_are_revits ... ok.Ports and connections were written earlier (#550, #552). What is still open here is flow direction, the
.SINK./.SOURCE.of each port, which RE-138 found no stored field for, and the few connections not yet read (7 of 73 on Mechanical, 6 of 126 on Plumbing).feat(ifc): every duct and pipe has a port at each end, joined or not …
DrunkOnJava commentedon Oct 4, 2026
Progress, 2026-10-04 (#673, B54): every duct and pipe now has a port at each end, joined or not. Revit's export writes connectors 0 and 1 of 92 of RE1's 94 ducts and pipes as ports whether or not anything is connected. rvt-rs wrote a port only for a join it read. With both end ports written, RE1 Plumbing has 255 ports against Revit's 260 (from 242) and every duct and pipe end port Revit writes on Mechanical and Plumbing is in the file, checked by
tests/duct_and_pipe_ports.rs. One port is extra: port 0 of pipe 444124, which is joined to the tank Revit's export leaves out.Next: a family instance's own connectors. Its FamilySymbol's native record lists them (
m_arrConnectorData, each with anm_index), and its Family has aConnectorDataCellper index with its domain. That is where Electrical's 53 ports and the open ports of fixtures and fittings should come from. It is being measured against Revit's port indices now.feat(ifc): a family instance has a port for each of its symbol's conn…
research(re): RE-169, a family instance's ports are its symbol's conn…
feat(ifc): a family instance written as a proxy has its ports, nested…
feat(native): an element's joins are read from its family instances' …
re: the joins the list form missed (RE-170) and the native connectors…
DrunkOnJava commentedon Oct 19, 2026
The acceptance here is met. Ports and connections are written for every element whose connectors are decoded, measured against Revit's own exports (Measure run 39261416282):
What is left is tracked on its own: an HVAC or piping connector's flow direction, every port's SystemType and a connector's description in #834, and the ports' placement, which Revit's export gives each port and rvt-rs does not yet, in #847.