You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
area:elementsWork in the elements area.area:ifcWork in the ifc area.priority:P1High-impact work needed for the MVP or beta path.research-criticalGated on format evidence or an oracle; not a release/security blocker (GOV-002)type:featureNew product or library capability.
STEP writer can emit multiple IfcBuildingStorey when IfcModel.building_storeys is populated
Current production reality (important)
RvtDocExporter ArcWall production path still sets building_storeys: Vec::new() (src/ifc/mod.rs), so real-project IFC falls back to the placeholder storey warning path
tests/fixtures/project-counts/2024-core-interior.json marks levels as known_gap with decoder_expected: 0 and unsupported_feature: "revit_levels_to_ifc_storeys"
Therefore claims that storeys are “15/15 done” on current main are overstated relative to the production exporter
Remaining vs AC
Decode Level names/elevations from real projects into production export
Assign elements to storeys via level references
Remove fallback-only Level 1 behavior for files with real levels (viewer scene tree too)
See progress note on #30 (PR #136). Level/storey elevations recover from ArcWall trailers + partition Level-like names on Einhoven; schema-driven Level from partitions remains open — not closing.
Production iter_elements now yields typed Level DecodedElements from ArcWall base elevations + partition building-storey names (≥4 on Einhoven with recovered elevations; names applied when confident).
Material / Room display-name recovers also surface (strict filters).
Still open vs AC: Level ElementId binding from ElemTable, IFC storey assignment for non-ArcWall elements, viewer scene-tree grouping by recovered levels (IFC path already had elevation-derived storeys from ArcWall). Keeping open.
IFC storeys match project levels.#218 (RE-24) recovers all 15 Revit Levels on 2024_Core_Interior.rvt with their names and elevations exact, each keyed by its own ElementId, and both project-count manifests gate storey_count at 15 with tolerance 0.
Elements are grouped under the correct storey.#267 (RE-27) reads the Level that the element record's own reference list names, accepting only an unambiguous single Level, and #278 (RE-29) gave the 116 rooms element records of their own. Containment is 969 of 970 exported elements. The rooms half is scored against Revit's own containment: the ten Levels they bind map one-to-one onto the storeys the export aggregates them into. The single element that stays unbound is a wall whose record names no unique Level, and it is contained in the IfcBuilding rather than filed under an arbitrary storey.
Viewer scene tree groups by actual levels. The deployed viewer shows the real storey names (Basement 2, Basement 1, Level 1, Mez 1-2, and so on) with their elevations and element counts.
Fallback-only Level 1 behaviour is gone: #267 also removed the unwrap_or(0) that silently placed every unbound element in the lowest storey.
Not claimed: the full 969-element containment set has not been scored element by element against Revit's IfcRelContainedInSpatialStructure; that reference comparison is still NOT MEASURED outside the room subset. The RE-20 negative also stands, so this binds by the record's Level reference and by elevation, not by a Level ElementId on Floors and Rooms in the schema-field sense.
area:elementsWork in the elements area.area:ifcWork in the ifc area.priority:P1High-impact work needed for the MVP or beta path.research-criticalGated on format evidence or an oracle; not a release/security blocker (GOV-002)type:featureNew product or library capability.
Activity
DrunkOnJava commentedon Aug 28, 2026
Triage / v0.2.0+ progress (2026-08-28) — keep open; temper earlier “15/15 done” claims
Audit against
main@21aa0e0(OPS-03 / #99).Shipped
Leveldecoder +storeys_from_levelsbridge exist (src/elements/level.rs,src/ifc/from_decoded.rs)IfcBuildingStoreywhenIfcModel.building_storeysis populatedCurrent production reality (important)
RvtDocExporterArcWall production path still setsbuilding_storeys: Vec::new()(src/ifc/mod.rs), so real-project IFC falls back to the placeholder storey warning pathtests/fixtures/project-counts/2024-core-interior.jsonmarks levels asknown_gapwithdecoder_expected: 0andunsupported_feature: "revit_levels_to_ifc_storeys"mainare overstated relative to the production exporterRemaining vs AC
Keep open.
feat: ArcWall trailer ElementId/elevation finish-line for Gate B
Lane Six: wall/floor geometry recovery (curves, loops, hosts, elevati…
Wire typed MVP + ArcWall partition decode into production iter_elemen…
DrunkOnJava commentedon Aug 29, 2026
See progress note on #30 (PR #136). Level/storey elevations recover from ArcWall trailers + partition Level-like names on Einhoven; schema-driven Level from partitions remains open — not closing.
Partition schema MVP: Levels/Floors/Materials into iter_elements (#140)
DrunkOnJava commentedon Aug 29, 2026
Progress (#140 /
partition_schema_mvp):iter_elementsnow yields typedLevelDecodedElements from ArcWall base elevations + partition building-storey names (≥4 on Einhoven with recovered elevations; names applied when confident).Still open vs AC: Level ElementId binding from ElemTable, IFC storey assignment for non-ArcWall elements, viewer scene-tree grouping by recovered levels (IFC path already had elevation-derived storeys from ArcWall). Keeping open.
Honest IFC/viewer wiring for partition Level/Floor/Material + opening…
DrunkOnJava commentedon Aug 29, 2026
Progress from PR #141 (
2a463d3):Shipped
Levelrecovers now form IFC storeys even when elevation is unresolved (name-only → elevation 0.0, documented).rvt-inspectshow production Level counts and IFC storey totals.Still open vs AC
Keeping open.
DrunkOnJava commentedon Aug 29, 2026
Progress (PR #143)
Shipped
IFCBUILDINGSTOREYnodes (name · elev · element count).storey_names;rvt-inspectprints them.Still open vs AC
Keeping open.
9 remaining items
research: third IFC witness (IFClite) and the full-project export edge (
feat: ArcWall trailer ElementId/elevation finish-line for Gate B
Lane Six: wall/floor geometry recovery (curves, loops, hosts, elevati…
Wire typed MVP + ArcWall partition decode into production iter_elemen…
Partition schema MVP: Levels/Floors/Materials into iter_elements (#140)
Honest IFC/viewer wiring for partition Level/Floor/Material + opening…
Viewer storey grouping + material name File Status (#33/#34)
Level ElementId storey bind + AProperty parameter surfaces (#144)
research: third IFC witness (IFClite) and the full-project export edge (
docs: record the bounded wasm inflate, the real-project demos, and th…
docs: catch the public docs up to #266, #267, #272, #273 and #274 (#276)
DrunkOnJava commentedon Sep 19, 2026
All three acceptance criteria are met.
IFC storeys match project levels. #218 (RE-24) recovers all 15 Revit Levels on
2024_Core_Interior.rvtwith their names and elevations exact, each keyed by its own ElementId, and both project-count manifests gatestorey_countat 15 with tolerance 0.Elements are grouped under the correct storey. #267 (RE-27) reads the Level that the element record's own reference list names, accepting only an unambiguous single Level, and #278 (RE-29) gave the 116 rooms element records of their own. Containment is 969 of 970 exported elements. The rooms half is scored against Revit's own containment: the ten Levels they bind map one-to-one onto the storeys the export aggregates them into. The single element that stays unbound is a wall whose record names no unique Level, and it is contained in the
IfcBuildingrather than filed under an arbitrary storey.Viewer scene tree groups by actual levels. The deployed viewer shows the real storey names (Basement 2, Basement 1, Level 1, Mez 1-2, and so on) with their elevations and element counts.
Fallback-only
Level 1behaviour is gone: #267 also removed theunwrap_or(0)that silently placed every unbound element in the lowest storey.Not claimed: the full 969-element containment set has not been scored element by element against Revit's
IfcRelContainedInSpatialStructure; that reference comparison is still NOT MEASURED outside the room subset. The RE-20 negative also stands, so this binds by the record's Level reference and by elevation, not by a Level ElementId on Floors and Rooms in the schema-field sense.feat(elements): contain elements naming two Levels in their base cons…
feat(elements): give railings their host's storey, and hosted element…