You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Design options: frame slot +0x2a names the option; leave out non-primary options once the primary flag is found #319
The element frame's third "never set" sentinel slot, +0x2a (the 24 bytes at +0x1a are three u64 slots), holds a design option ElementId when the element belongs to one. Measured on Snowdon Towers Architectural (Revit 2024, local only) against the VIM export's Vim.DesignOption table and Revit's own IFC4 export:
the one generic model outside Revit's export (RE-36);
the only slab edges that keep OST_EdgeSlab out of RE-37.
What is missing
rvt-rs cannot yet tell a primary option from a non-primary one:
The option records (category −2006114) are byte-identical in shape.
The option-set records (−2006112) list their options in ascending id order, with no marker.
The primary is 1500724 (the smallest of its set) in one set and 2059970 (the largest) in the other, so order does not decide it.
To do
Find where Revit stores the set's primary option (candidates: Global/Latest document data, a parameter block in the partitions).
Once it is found, leave out instances in non-primary options, report them as a skipped item, and add OST_EdgeSlab (59 exported by Revit, 9 omitted, all 9 in option 2059967).
Activity
feat(elements): export lighting fixtures, air terminals, food service…
feat(elements): leave out non-primary design options and export slab …