Repository navigation
Closed
Labels
area:geometryWork in the geometry area.area:ifcWork in the ifc area.priority:P1High-impact work needed for the MVP or beta path.research-criticalGated on format evidence or an oracle; not a release/security blocker (GOV-002)type:featureNew product or library capability.
Description
Created from the roadmap audit in TODO.md.
Source: https://github.com/DrunkOnJava/rvt-rs/blob/main/TODO.md#L553
Tracking commit: 1ec8105
Scope
Labels: priority:P0, type:feature, area:geometry, area:ifc
- Decode wall location curve, base level, top constraint/height,
thickness, flip/orientation, and curve type. - Support initially:
- straight wall
- arc wall
- rectangular extrusion
- Defer complex BRep with explicit diagnostics.
Acceptance criteria:
- Known corpus walls export as
IfcWallwithIfcShapeRepresentation. - Viewer shows walls in correct rough positions.
- Revit 2023 and 2024 wall count tests pass.
Definition of done
- The TODO acceptance criteria for this section are implemented or explicitly superseded by a linked decision.
- Tests, fixtures, or documentation are added at the level appropriate to the change risk.
- User-facing behavior and limitations remain honest in README/docs/viewer messaging.
- Relevant CI checks pass before the issue is closed.
Metadata
Metadata
Assignees
Labels
area:geometryWork in the geometry area.area:ifcWork in the ifc area.priority:P1High-impact work needed for the MVP or beta path.research-criticalGated on format evidence or an oracle; not a release/security blocker (GOV-002)type:featureNew product or library capability.
Activity
DrunkOnJava commentedon Aug 28, 2026
Triage / v0.2.0+ progress (2026-08-28) — keep open
Audit against
main@21aa0e0/b52397b(OPS-03 / #99).Shipped
IfcWallswept solids (src/arc_wall_record.rs,src/ifc/mod.rs,tests/arc_wall_corpus.rs, real-IFC CI gate)tests/fixtures/project-counts/revit-ifc5-einhoven.json)Remaining vs AC
Keep open. Next: #23 (2024 envelope) + #81 (recall) + #88 (compound layers).
feat: ArcWall trailer ElementId/elevation finish-line for Gate B
Lane Six: wall/floor geometry recovery (curves, loops, hosts, elevati…
DrunkOnJava commentedon Aug 29, 2026
Progress note from production
iter_elementswiring (#136):iter_elementsyields ≥20 ArcWallDecodedElements; Lane Sixrecover_wall_location_curve*recovers centerlines for all of them. Schema-drivenWallfrom arbitrary partitions still open; synthetics stayAbsent.Levelfrom partitions still open.Not closing these issues — remaining work is schema-driven partition decode beyond ArcWall.
Wire typed MVP + ArcWall partition decode into production iter_elemen…
DrunkOnJava commentedon Aug 29, 2026
Progress note from partition schema MVP (
partition_schema_mvp→ productioniter_elements, PR #140):Shipped this iteration
iter_elementsyields ≥4LevelDecodedElements on Einhoven 2023 (elevation + building-storey names from ArcWall trailers + partition strings). Geometryrecover_level_elevationrecovers for those rows.Floorwithm_boundary;recover_floor_boundaryrecovers ≥1 loop on Einhoven (sourcePartitionPlanLoop). Not ElemTable-bound; not full slab extrusion AC.Wall/ 2024 ArcWall tag drift unchanged.ArcWallRectOpeningindex rows merge as classArcWallRectOpeningwith related-id / unvalidated host provenance — not typedDoor/Window. Einhoven 2023 remains 0 doors/windows (honest).Keep open
Not closing #30–#33.
Partition schema MVP: Levels/Floors/Materials into iter_elements (#140)
Honest IFC/viewer wiring for partition Level/Floor/Material + opening…
DrunkOnJava commentedon Aug 29, 2026
Progress from PR #141 (
2a463d3, post-#140):Advanced
schema_field_wall_instancesas an explicit unsupported feature (no invented schema-fieldWallrows).Still open vs AC
Wallstill unsolved (real schemas lack literalWall; VWall/2024 ArcWall envelopes differ — M3-02: Reverse-engineer Revit 2024 ArcWall records #23).Keeping open. #23 skipped this iteration (no measurable 2024 envelope decoder without boiling the ocean).
docs(RE-19): negative Door/Window discriminator + 2024/schema Wall
4 remaining items
DrunkOnJava commentedon Aug 30, 2026
Relabelled P0 → P1 + research-critical (audit finding GOV-002: P0 is reserved for immediate release or security impact; this item is gated on format evidence / an oracle, which engineering time alone does not change). Scope and status are unchanged.
research: third IFC witness (IFClite) and the full-project export edge (
feat: ArcWall trailer ElementId/elevation finish-line for Gate B
Lane Six: wall/floor geometry recovery (curves, loops, hosts, elevati…
Wire typed MVP + ArcWall partition decode into production iter_elemen…
Partition schema MVP: Levels/Floors/Materials into iter_elements (#140)
Honest IFC/viewer wiring for partition Level/Floor/Material + opening…
RE-19: negative Door/Window discriminator + schema-field/2024 Wall
research: third IFC witness (IFClite) and the full-project export edge (
DrunkOnJava commentedon Sep 19, 2026
Closed by 61c05d3 (#211) and 62d7d85 (#215). The Revit 2024 partition element-record rule recovers 360 of 360
IfcWallon2024_Core_Interior.rvtas an exact ElementId set with no false positives and no misses, gated at tolerance 0 intests/fixtures/project-counts/2024-core-interior-slim.json. The body carries the wall's real thickness (thin plan extent equals theIfcWallTypenominal width on 360 of 360) and the plan run left by its joins, which puts 336 of 360 walls inside 1e-3 ft of Revit's own export in world coordinates, up from 27. Evidence:reports/element-framing/RE-21-partition-element-record-instance-rule.mdandRE-26-world-coordinate-residuals.md; the 31 remaining over-trimmed ends are tracked separately in #238.docs: record the bounded wasm inflate, the real-project demos, and th…
fix(ifc): Revit 2023's ArcWall pattern no longer writes a curtain wal…