Skip to content

Opening geometry from the symbol's cut loop on releases other than 2024 and 2025: no Revit export of another release's openings is in CI #227

Open

Description

@DrunkOnJava

After RE-23 (#226) every door/window opening chain matches Revit's (138/138), but the opening body is the filling element's bbox on its own placement, not a wall-relative cut, and the export's other 63 openings (42 slab, 20 shading-device, 1 unfilled wall) are not recovered. Do: (1) express the opening in the host wall's local frame using the wall location curve and thickness (the RE-21 bbox gives the extents); (2) find the slab/shading-device penetrations in the element records (the same counted reference list at +0x88 may name the host) and score them against IfcRelVoidsElement pairs whose filling is absent — exact set or nothing; (3) extend the relations surface with IFCRELVOIDSELEMENT pairs once both sides are comparable.

Activity

  1. self-assigned this
    on Aug 30, 2026
  2. DrunkOnJava commented on Aug 30, 2026

    @DrunkOnJava
    OwnerAuthor

    RE-26 (PR #237) status for this issue: door/window bodies remain the record envelope where Revit exports a panel. World-AABB residuals after the newest-frame fix: doors 0/132 exact (max 2.92 ft, mean 2.92), windows 0/6 (4.82), openings 0/138 (max 4.92). The frame change moves 96 doors (24 better, 72 worse) and no measurement on this file adjudicates it — a door record's box is not the panel Revit exports; scored against the export's own opening bodies the two frames are equally far apart. Host binding is untouched: 138/138 either way (no door/window record's frames disagree on the preceding reference).

    Full tables in reports/element-framing/RE-26-world-coordinate-residuals.md.

  3. DrunkOnJava commented on Sep 28, 2026

    @DrunkOnJava
    OwnerAuthor

    #440 (RE-83) cuts each door's and window's opening to its host wall's depth: Core Interior 138 of 138 within 0.25 ft of Revit's opening (none before), Snowdon Towers 72 of 110 within 0.26 ft (none before). Width and height stay the element's box (the type's Width/Height keys are not decoded), and openings in walls that are not straight extrusions keep the element's box; the Snowdon residual is itemised in reports/element-framing/RE-83-openings-through-walls.md. Still open here: Revit's opening profile, slab and shading-device penetrations, and the extra unfilled openings where one element cuts several walls. The follow-up for doors and windows that are only openings is RE-84.

  4. 105 remaining items

  5. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    The openings of other releases, measured against Revit's exports, from the held-out pairs (counts only). #2030 makes the held-out scrub keep opening_boxes_vs_ifc's counts, and Measure 43662939537 ran it on main (e6201f4c). Each opening is keyed by the Tag of the door or window filling it, and both files are moved into Revit's internal frame through their own site placement. The count is of openings within each distance of Revit's box.

    held-out pair release openings (Revit / rvt-rs / both) within 0.001 ft farther
    rvt-holdout (one project) 2022, 2024, 2025, 2026, 2027 15 / 15 / 15 each 3 doors, 12 windows: 15 of 15 on every save none
    rvt-holdout-office (one project) 2022, 2024, 2025, 2026, 2027 14 / 14 / 14 each 4 doors, 10 windows: 14 of 14 on every save none
    teste_export_2025 2025 1 / 1 / 1 1 window none
    modelo_bim 2023 11 / 11 / 11 1 door, 10 windows none
    flowbim.ee house 2026 19 / 29 / 19 13 doors windows: 2 within 0.1 ft, 4 within 1 ft
    BIM-Speed Warmond 2021 184 / 250 / 184 128 doors, 56 windows none
    BIM-Speed Gdynia 2021 37 / 37 / 37 15 doors, 21 windows 1 door within 1 ft
    BIM-Speed Vitoria project 2018 135 / 133 / 133 54 doors, 3 windows 14 doors and 19 windows over 1 ft, 43 windows within 1 ft
    BIM-Speed Frigento 2020 55 / 56 / 55 none 23 doors over 1 ft, 3 within 1 ft, 29 windows within 0.1 to 1 ft
    BIM Whale AdvancedProject 2021 389 / 389 / 389 none 123 doors over 1 ft, 3 within 1 ft, 263 windows within 1 ft

    So the retitled question has an answer for 2022, 2026 and 2027. Two projects saved in each of 2022 to 2027 place every door and window opening within 0.001 ft of Revit's, as do modelo_bim (2023) and Warmond (2021). What is still wrong is file-specific:

    • the 2026 house's 6 windows (and 10 openings rvt-rs writes that Revit's export has none of);
    • most of the openings of Vitoria (2018), Frigento (2020) and BIM Whale (2021), where whole classes miss by up to a foot or more. That suggests a different cut-loop or placement case, not a release.

    The held-out models keep counts only, so these confirm or refute and cannot shape a rule. The next step is to find what the three poor files share, on a model whose details we may read, and the BIM-Speed archive's spent ALD26 Before (Revit 2018, measured in full) is the first candidate.