Revit 2027: stair and flight types are written NOTDEFINED where Revit's export writes USERDEFINED (CHL, one export) #2110

Open

Description

@DrunkOnJava

On a reporter's Revit 2027 model (CHL, a Spanish Revit), Revit's own IFC4 export writes USERDEFINED, with an ElementType of NOTDEFINED, on the types of the 9 of its 18 flights that are not STRAIGHT, and types 7 of its 8 stairs USERDEFINED, where rvt-rs writes NOTDEFINED (#2046, measured by @HWT-25 on rvt-rs 5e36af9f, flights paired by GlobalId).

What else has been read. One other Revit export: Snowdon Towers Architectural's (Revit 2024, local only) writes none of its 30 stairs, 49 flights, 13 stair types or 7 flight types USERDEFINED. The exports Measure scores against (the BIM4LCA housing and office, the Revit 2025 stair models) have not been read for the type objects' PredefinedType; #1713 read the elements' own, which Revit writes NOTDEFINED there. Why Revit writes USERDEFINED on CHL is not read.

What rvt-rs does meanwhile. It keeps NOTDEFINED there while this one export is the only witness.

What would settle it:

  • the stair and flight type objects of the exports Measure scores against, read for PredefinedType;
  • where revit-ifc writes USERDEFINED and an ElementType on a stair or flight type (ExporterUtil.CreateGenericTypeFromElement, StairsExporter; CLEANROOM.md source 5);
  • a second Revit export of a model that shows it.

Activity

  1. added
    area:elements
    area:ifc
    priority:P3
    type:research
    on Nov 20, 2026
  2. added a commit that references this issue on Nov 20, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:elementsarea:ifcpriority:P3type:research

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions