Ordinary walls' Length before Revit 2024: 8 walls of one held-out Revit 2021 project are written and nothing checks them; score them against Revit's Axis #2069
area:elementsWork in the elements area.priority:P2Important quality, usability, or hardening work.type:researchReverse engineering, discovery, or design investigation.
v0.25.0 gives an ordinary wall Qto_WallBaseQuantities.Length on Revit 2015 to 2023 saves as well, by the rule Revit 2024 and later already had (RE-252): where the wall's cut-back curve is as long as its curve. On the Autodesk samples it writes none. On one held-out Revit 2021 project (BIM Whale's) it writes 8 of 390 walls', and that project's Revit export is IFC2X3 with no base quantities, so nothing scores them: Measure run 43721278321 lists them as extra Qto_WallBaseQuantities.Length: 8, counted apart, and the release notes say they are checked by nothing.
RE-364 section 11 called these 8 curtain walls. They are ordinary walls (the writer's curtain-wall set is Qto_CurtainWallQuantities; the project's Revit export holds IfcWall 9, IfcWallStandardCase 381 and no IfcCurtainWall). The correction is section 12 of the same report, in the post-release docs pull request.
The check
That export still writes each wall's Axis curve, and in Revit's export the Axis is the wall's curve cut back at its joins (RE-252). Where the rule writes a Length, the cut-back curve is as long as the curve, so the length of Revit's own Axis for the same wall (paired by Tag) must equal the Length rvt-rs wrote. That needs no base quantities in Revit's export.
tools/re/qtos_vs_ifc.py already reads Axis lengths (axis_lengths) to tell which of the two lengths Revit wrote where it wrote a Length. It needs one more line: for each wall rvt-rs gives a Length and Revit's export gives none, whether that length is within 1e-4 ft of the Axis's, differs from it, or the wall has no straight Axis. The held-out scrub keeps the line, so a held-out project is checked as counts only.
What the result decides
8 of 8 within 1e-4 ft: the rule stays on Revit 2015 to 2023, and RE-364 records that its ordinary-wall Length is checked against Revit's Axis there, not against Revit's quantities.
Rows for the check, written before the run is read.
The scorer change is branch ci/2069-wall-length-axis (8b86b2f). The run is Measure with --ref ci/2069-wall-length-axis, ref=v0.25.0 (e3a9404), base=none, holdout=true, scorers=qtos_vs_ifc, on the held-out Revit 2021 project, Core Interior and the BIM4LCA office as built.
The held-out Revit 2021 project: the new line reads equal 8; differ 0; no Axis 0. A differ or a no Axis is a finding about the rule on Revit 2015 to 2023 (narrow or gate it), unless the scorer's own read of Revit's Axis is shown wrong first.
Core Interior and the BIM4LCA office: Revit's export writes a Length on every wall there, so the line reads equal 0; differ 0; no Axis 0. Anything else is a scorer fault.
Every other line of each model's qtos_vs_ifc.txt is as the scorer printed it in run 43721278321: the change only adds a line.
The run is Measure 43733752273 (--ref ci/2069-wall-length-axis, 8b86b2f; ref=v0.25.0, base=none, holdout=true, scorers=qtos_vs_ifc). The rows above, read now:
The held-out Revit 2021 project: pass.walls rvt-rs gives a Length and Revit's export does not, against the length of Revit's Axis (within 1e-4 ft): equal 8; differ 0; no Axis 0. All 8 ordinary-wall Length values v0.25.0 writes there equal the length of Revit's own Axis for the same wall.
My row was wrong, and the result is better than I wrote. I expected equal 0 on Core Interior, taking Revit's export to carry a Length on every wall. Its slim export has no base quantities at all (RE-242), so the 38 wall Length values rvt-rs writes there take the same path: equal 38; differ 0; no Axis 0. That is not a scorer fault; the path fired as designed. The BIM4LCA office was not in the run (nordic=true was not set), so its row is open and no longer needed.
Every other line is unchanged. Core Interior's qtos_vs_ifc.txt differs from the one in run 43721278321 by the new line only, and every other qtos_vs_ifc line of the held-out project's counts.txt is in the earlier run's.
By the criteria in the issue, 8 of 8 within 1e-4 ft: the rule stays on Revit 2015 to 2023. What it rests on is stated plainly: the rule is the one measured on Revit 2024 and later, run on the older save's record, and for ordinary walls the older saves give it one project, 8 of 390 walls, checked against Revit's Axis and by no quantity of Revit's. RE-364 records that with the section 12 correction once the scorer line is on main (#2071), so its reproduce lines can name main.
area:elementsWork in the elements area.priority:P2Important quality, usability, or hardening work.type:researchReverse engineering, discovery, or design investigation.
Activity
DrunkOnJava commentedon Nov 15, 2026
Rows for the check, written before the run is read.
The scorer change is branch
ci/2069-wall-length-axis(8b86b2f). The run is Measure with--ref ci/2069-wall-length-axis,ref=v0.25.0(e3a9404),base=none,holdout=true,scorers=qtos_vs_ifc, on the held-out Revit 2021 project, Core Interior and the BIM4LCA office as built.equal 8; differ 0; no Axis 0. Adifferor ano Axisis a finding about the rule on Revit 2015 to 2023 (narrow or gate it), unless the scorer's own read of Revit'sAxisis shown wrong first.Lengthon every wall there, so the line readsequal 0; differ 0; no Axis 0. Anything else is a scorer fault.qtos_vs_ifc.txtis as the scorer printed it in run 43721278321: the change only adds a line.DrunkOnJava commentedon Nov 15, 2026
The run is Measure 43733752273 (
--ref ci/2069-wall-length-axis, 8b86b2f;ref=v0.25.0,base=none,holdout=true,scorers=qtos_vs_ifc). The rows above, read now:walls rvt-rs gives a Length and Revit's export does not, against the length of Revit's Axis (within 1e-4 ft): equal 8; differ 0; no Axis 0. All 8 ordinary-wallLengthvalues v0.25.0 writes there equal the length of Revit's ownAxisfor the same wall.equal 0on Core Interior, taking Revit's export to carry aLengthon every wall. Its slim export has no base quantities at all (RE-242), so the 38 wallLengthvalues rvt-rs writes there take the same path:equal 38; differ 0; no Axis 0. That is not a scorer fault; the path fired as designed. The BIM4LCA office was not in the run (nordic=truewas not set), so its row is open and no longer needed.qtos_vs_ifc.txtdiffers from the one in run 43721278321 by the new line only, and every otherqtos_vs_ifcline of the held-out project'scounts.txtis in the earlier run's.By the criteria in the issue, 8 of 8 within 1e-4 ft: the rule stays on Revit 2015 to 2023. What it rests on is stated plainly: the rule is the one measured on Revit 2024 and later, run on the older save's record, and for ordinary walls the older saves give it one project, 8 of 390 walls, checked against Revit's
Axisand by no quantity of Revit's. RE-364 records that with the section 12 correction once the scorer line is onmain(#2071), so its reproduce lines can namemain.ci(measure): the quantity scorer checks a wall Length rvt-rs writes a…