Skip to content

Ducts on the BIM4LCA housing: 1 of Revit's 3 written, its box 3.0 ft off (RE-212, RE-370, RE-371) #1989

Closed

Description

@DrunkOnJava

On the BIM4LCA housing, the second project, the ducts do not hold: rvt-rs writes 1 of the 3 ducts Revit's export holds per large file, and that one's box is 3.0 ft from Revit's after the scorer's site-frame repair (RE-402 sections 6.1 and 7, duct_bodies_vs_ifc run 2). Ports and pipes are not exercised there.

The duct rules were measured on RE1 Plumbing, Mechanical and Electrical (RE-212), Autodesk's samples, RE1 and the BIM4LCA office (RE-370), and Autodesk's samples, RE1 and Snowdon Towers HVAC (local only, RE-371).

Done when the two ducts rvt-rs leaves out are named with the stage that drops them (element_record_stages), and the written duct's 3.0 ft offset is explained and fixed or counted, so the housing's ducts read as Revit's or the gap is stated.

Listed in "Measured on another project, and wrong there" on Rules that rest on one project (#1636, #1979).

Activity

  1. added
    area:elements
    priority:P2
    type:bug
    on Nov 14, 2026
  2. DrunkOnJava commented on Nov 14, 2026

    @DrunkOnJava
    OwnerAuthor

    Found, and fixed in draft #2006 (RE-468).

    The "ducts" are three gutters. duct_bodies_vs_ifc counts flow segments, and the three of the housing (elements 1567789, 1567790 and 1629154, family HLV-1.125) are Gutter elements. rvt-rs wrote all three, none dropped by a stage: two as IfcCovering ROOFING and one as IfcPipeSegment. The 3.0 ft box offset is gone since the scorer's site-frame repair (worst 0.00000 ft on the one it matched).

    What Revit writes. In each of the six housing files each gutter is an IfcFlowSegment with no PredefinedType, typed by an IfcPipeSegmentType GUTTER. Two of them carry an "Export to IFC As" of IfcCovering, as the roofing elements around them do, and Revit ignores it on a gutter (as it does a wall sweep's, RE-192); the office's 24 gutters carry IfcPipeSegment and Revit acts on that. Probe probe_re45_ifc_export_parameters, Measure 43583970009.

    The change. A gutter defaults to IfcFlowSegment, an IfcPipeSegment value on it is acted on, and an IfcCovering one is not. Measure 43587477298, on the four large housing files: ducts written for Revit's 3, 1 to 3 of 3, every box within 0.01 ft; IfcFlowSegment same 0 to 3 of 3; no count that equals Revit's falls. The gutters' names and ObjectType still differ from Revit's and are the one gap left (RE-468 section 6).

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:elementspriority:P2type:bug

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions