You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Opening Reference, sloped floor PitchAngle and door FireRating write values Revit leaves out on the BIM4LCA housing (RE-381, RE-384, RE-354) #1987
Three rules that hold on the BIM4LCA concrete office, where they were developed, write a value that Revit's export leaves out on the BIM4LCA housing, the second project. RE-402 section 3, census cells equal/different +written-that-Revit-omits, by file (concrete as built, concrete permit, timber as built, timber permit, terrain concrete, terrain timber):
Rule
Housing
Verdict
RE-381/382 opening Reference
35/0 +1, 20/0 +1, 19/0 +1, 19/0 +1, -, -
does not hold on 4
RE-384 sloped floor PitchAngle
26/0, 32/0, 34/0 +1, 34/0, 1/0 +2, 1/0 +2
does not hold on 3
RE-354 door FireRating
17/0, 17/0 +1, 18/0, 18/0, -, -
does not hold on 1
None reads "different": each is a value rvt-rs writes on an element where Revit writes none. The concrete office already counts the opening Reference this way (+3, +4, +2, +2, RE-402 section 3), so that rule fails on its first project too.
Done when each of the 10 elements is named (PSETS_MISSING, or the census's list of values Revit does not write), the reason Revit leaves its value out is found, and the rule is narrowed so it writes none of them, with no equal value lost on the office or the housing. Or, where Revit's exporters disagree on the value, it is left out by the standing rule.
Named, on main 8da5d029 (Measure 43554418103). psets_vs_ifc now lists, for each property PSETS_MISSING names, every object where rvt-rs writes the property and Revit does not, and whether Revit writes the object at all (branch research/1987-extra-values at 3ecfe1d4). Since RE-402, the terrain files' two PitchAngle values are gone. What is left:
Property
Where
What it is
Pset_OpeningElementCommon.Reference
housing, all four large files
the void of element 1732546 in wall 1427469, an IfcOpeningElement Revit's export does not write at all
Pset_OpeningElementCommon.Reference
office: 3 as built, 4 at permit
likewise openings Revit does not write, in walls 1815838, 1892039 and 1494012 (as built), 1728013 (2), 2114950 and 3363820 (permit)
Pset_SlabCommon.PitchAngle
timber housing as built
0 on 2337931, Compound Ceiling:AK-4.EI60, a ceiling exported as IfcSlab: RE-238's level-slab rule, measured on floors, roofs and landings only. Draft #1992 leaves ceilings out.
Pset_DoorCommon.FireRating
concrete housing at permit
EI30 on door type 1743417, a type object Revit writes without it
So RE-381's Reference is not wrong where it is written: each of these values sits on an opening Revit does not write, and the fix is the opening, not the property. That is the reverse of #1165 (openings Revit writes and rvt-rs does not). Next: why Revit writes no opening for element 1732546 in wall 1427469, and the door type's FireRating.
On the door type's FireRating (1743417, EI30, concrete housing at permit): the export's diagnostics for that file (43554519222) carry no "type text parameter(s) ... are left" warning, so the type's saved copies of "Fire Rating" agree. The value is what the file holds, and a stale copy (RE-431, RE-446) is not the cause. Revit's export writes the type object 1743417 with Pset_DoorCommon and no FireRating, on this file only: as built and on the timber files RE-354's door FireRating reads equal. Next: what Revit writes on that type's doors (their own FireRating and the parameter it comes from), which needs this file's two exports side by side.
Door type 1743417's FireRating: Revit writes it on the type in the two timber housing files and leaves it out in the concrete housing at permit. Nothing either export holds tells the files apart.
A scorer on research/1987-extra-values (tools/re/door_type_fire_rating_vs_ifc.py, at 8c2087e6) lists each door or window type whose Pset_DoorCommon.FireRating / Pset_WindowCommon.FireRating rvt-rs writes. It sets every fire property of both exports beside each other, on the type and on each of its doors. Measure 43560756545, BIM4LCA housing and offices:
file
type 1743417 O-2.10+4x21, Revit
rvt-rs
its one door 1507966, Revit
rvt-rs
housing concrete, permit
Pset_DoorCommon with no FireRating
EI30
EI30
EI30
housing timber, as built
EI30
EI30
EI30
EI30
housing timber, permit
EI30
EI30
EI30
EI30
housing concrete, as built
no type FireRating on either side
The type's name, value and door are the same in the three files that list it, and so are the door's own values (FireRatingEI30, FireExit true). Revit writes the type's Pset_DoorCommon in all three.
On the offices, every type whose FireRating rvt-rs writes is written by Revit with the same value: 6 types as built, 5 in the timber office. That includes O-1.12x21, whose doors carry EI60 against the type's EI30.
No "type text parameter(s) ... are left" warning on any of these files: rvt-rs reads one value from the type.
So it is the one extra FireRating left on the census, and it is not a reading error: the file holds EI30 on the type, and Revit's export of a sibling project writes the same type with it.
The concrete as-built file's empty row is not read yet. It is either rvt-rs writing no FireRating on that type there, or the type being absent from one export.
Next: what the concrete files hold on that type that the timber files do not, read by a probe of the type's parameters in all four files. Until a difference is found, the value stays counted under "values Revit does not write" and nothing is narrowed.
Door type 1743417: what the four housing files hold.probe_re207_element_parameters on main (Measure 43587566137) prints door 1507966 with its own parameters and its type's, in all four large housing files.
Every type-level parameter of 1507966 is the same in all four files, Fire Rating included. So is every instance parameter but one.
That one is a shared instance parameter named Pset_DoorCommon.IsExternal (id 1350278), which the two timber files hold on the door and the two concrete files do not.
Revit's export writes the type's FireRating in both timber files and leaves it out in the concrete file at permit. So the one difference in the saved parameters lines up with the export's choice, but it rests on two pairs of states of one building, and nothing ties a door's IsExternal parameter to its type's FireRating. No rule is written on that.
A second question on our side: rvt-rs writes the type's FireRating in the concrete file at permit and none in the concrete file as built, from type parameters that are the same. The kept exports of the two concrete files (run 43588600114) should show which path writes the type object in each.
Why rvt-rs writes the type's FireRating at permit and not as built (kept exports, run 43588600114): the door type object 1743417 carries Other and Identity Data in both concrete files, and Pset_DoorCommonFireRatingEI30 only at permit. Neither file's diagnostics carries the RE-354 "type text parameter(s) ... are left out" warning, so no copies disagree. The type's FireRating comes from the byte reader of family type table entries (partition_type_parameters, RE-354), which finds an entry for this type at permit and none as built, where the native parameter read (native_element_parameters, the probe above) finds the same Fire Rating in both.
So as built, rvt-rs matches Revit's export only because its table reader misses the entry, not because it knows to leave the value out. At permit the reader finds it, and Revit's export leaves it out. What decides Revit's choice is still not found, and the value stays counted under values Revit does not write.
The openings rvt-rs writes and Revit's export does not: how Revit draws their hosts. A scorer on research/1987-extra-values (tools/re/extra_opening_hosts_vs_ifc.py, at ce948168) lists each unfilled opening rvt-rs writes that Revit's export lacks, with Revit's host body, the host's openings in Revit's export and the class Revit gives the cutter. It also splits the openings both write by host body and cutter class. Measure 43589175961 and 43589555232, main 32ed4e6a:
file
extra (cutter in host)
Revit's host body
host's openings in Revit's export
cutter in Revit's export
housing concrete as built
1732546 in 1427469
Tessellation
0
none
office as built
1815871 in 1815838
Tessellation
0
IfcCurtainWall
office as built
1892067 in 1892039
Tessellation
0
IfcCurtainWall
office as built
3388647 in 1494012
Tessellation
0
IfcFireSuppressionTerminal
office permit
1728679 in 1728013
Tessellation
0
IfcDoor
office permit
2793737 in 2114950
Tessellation
3
none
office permit
3387194 in 3363820
Tessellation
1
IfcFireSuppressionTerminal
office permit
3390319 in 1728013
Tessellation
0
IfcFireSuppressionTerminal
timber office, both states
1832410 in 1727582
Tessellation
1
IfcDoor
timber office, both states
3673827 in 1728013
Tessellation
0
IfcFireSuppressionTerminal
Every host is a tessellated body in Revit's export. That doesn't decide it, though: of the openings both write, on tessellated hosts, Revit writes 39, 38 and 39 cut by a cabinet (office as built, permit, timber), 13, 6 and 7 by a curtain wall, 13, 21 and 1 by a door, and 25, 19 and 14 by no element it writes. So no host body and cutter class pairing separates the extras from the openings Revit writes. Six of the extras are in a host where Revit's export writes no opening at all, but that is the result, not something the file says.
No rule is written. These stay counted as the opening Reference values Revit does not write, as before. A new signal would be needed to go further: the cutter's or host's native record, or Revit's tessellated host checked for whether the hole is cut into its mesh.
Next signal, rows registered before the run is read: is the hole cut into Revit's tessellated host? A scorer on research/1987-hole-cut (tools/re/opening_holes_vs_ifc.py, 6fb94307; Measure 43691906949, the BIM4LCA office and housing on main5f442efc) takes, for each unfilled opening rvt-rs writes, the grid points inside both the opening's body and rvt-rs's host body with no opening subtracted: the material the opening removes. It then gives the share of those points inside Revit's body of the same host, also with no opening subtracted. A share near 0 means Revit drew the hole into its body, and near 1 means it did not.
A dry run on Snowdon Towers (local, against Revit's own IFC4 export) shows the measure alone does not separate. Of the openings both exports write on tessellated hosts, 10 read cut, 6 part and 6 not scored. Of the 3 extras, the one scored reads cut (0.000).
Rows:
Known answer. Of the openings both exports write on a tessellated host, at least 90% of those scored read below 0.5 on each file. Otherwise the measure is not reading the hole, and nothing below is read.
Separates. At least 8 of the 10 extras listed above score above 0.95 (the hole is not in Revit's body). Then Revit's export leaves out the openings it did not cut into its body, and the next step is a record-side signal for a cut that does not happen: the host's saved mesh, read the same way.
Does not separate. The extras score below 0.5 as the both-written openings do. Then Revit cut those holes and left the opening out for another reason, and that is recorded as a negative for this signal.
The hole is cut: row 3 holds, so this signal does not separate (Measure 43691906949, opening_holes_vs_ifc at 6fb94307, archived at refs/archive/2026-11-15/cited/6fb943077fe4).
Row 1 (known answer) holds. Of the openings both exports write on a tessellated host, every one scored reads below 0.5 on all eight files: 76 of 77 cut and 1 part on the office as built, and 17 of 18 cut and 1 part on the concrete housing.
Row 2 does not hold. Row 3 does. 9 of the 10 extras can be scored, and each of the 9 reads 0.000: 1732546 in all four housing files, 1815871, 1892067, 3388647, 2793737, 3387194, 3390319 and 3673827. Revit drew each hole into its own body of the host and still wrote no IfcOpeningElement for it. 1728679 and 1832410 (both cut by a door) have no points inside both rvt-rs's opening and its host, so they are not scored.
What revit-ifc says about which openings are written (CLEANROOM.md source 5, read and cited only, at 7fe314fd):
OpeningUtil.AddOpeningsToElement writes the openings ExporterIFCUtils.GetOpeningData returns for the host. That call is native and cannot be read.
Beyond it, an opening is left out only for:
a WallSweep cutter whose category is not exported;
a door or window hosted by the wall, whose opening is left to its own export (DoorWindowDelayedOpeningCreator);
an opening solid with no body;
an extrusion with no loops or no plane.
One reading of WallExporter: a wall that is neither an extrusion along its axis nor a vertical extrusion of its body is given openings only if it is an in-place wall. That would predict no opening on any basic wall Revit draws tessellated. It fails on Snowdon Towers, against Revit's own IFC4 export (local, counts only), with tools/re/opening_host_kinds_vs_ifc.py (944fc015, archived). Revit's export writes 20 unfilled openings on basic walls it draws as a Tessellation, and its 3 extras are on such walls too. That reading does not separate them.
So which unfilled openings Revit's export writes is decided in native code. Neither the host's body, nor the cutter's class, nor whether the hole is cut tells the 10 apart from the openings it writes. The opening Reference values on them stay counted as values Revit does not write, and no rule is written. Two further signals would be: the cutter's native record (what it is in the file and how it names its host), and whether GetOpeningData's result depends on the cut's own record, the host's m_cutList or similar, read from the bytes.
Correction to the two comments above: Snowdon's 3 "extras" are not extras. rvt-rs's 1993286, 1993355 and 1993375 in wall 698364 are the same openings Revit's export writes as 1993278, 1993305 and 1993365. Each pair's box is equal to 0.001 ft (local, against Revit's own IFC4 export).
The Tags differ because both are lines of the wall's edited elevation profile (CurveElem records of its VarSketch 1993272; probe probe_1987_cut_ids at 69a83c79, Measure 43693331497), and each export names another line of the pocket's stretch. That is RE-380's known gap: Revit names the stretch's first line on 12 of 15 pockets and its last on these 3.
So this issue's openings Revit does not write are the BIM4LCA files' 10, and the Snowdon dry-run row of the hole check above is about these 3 paired openings, not extras. The rest of the hole-check result stands: all 9 of the BIM4LCA extras that could be scored are cut into Revit's body.
RE-380's Tag question, one more signal ruled out: the direction a sketch line is drawn in. RE-380 checked the polygon's winding, the extrusion direction, the profile axis and the sketch list's order, but not the drawn direction of each CurveElem's GLine (origin + direction × each end parameter). On wall 698364 the line Revit names is the one whose drawn end is the stretch's end, so that was tested on every pocket.
Probe probe_380_sketch_line_directions (35c3ccaf, archived at refs/archive/2026-11-15/cited/35c3ccafa3dd; Measure 43696351482), with each sketch's loop, convex hull and pockets rebuilt locally. Snowdon is read against Revit's own IFC4 export, local, counts only. Core Interior and the terrain office are read against RE-380's Tags 55859 and 1389018.
rule for the Tag
Snowdon, 13 pockets
Core Interior 55840
terrain 1387731
first line of the counter-clockwise stretch
9
yes
yes
last line
4
no
no
the end line whose drawn end is the stretch's end
7 alone, 2 tied
yes
yes
lowest id
8
no
no
highest id
4
yes
yes
The drawn direction does not decide it. On wall 698364 the lines run with the walk and Revit names the last line. On sketch 1992769 every line runs against the walk, and Revit names the last line there too. On sketches 1271797 and 2270836 the lines run with the walk, and Revit names the first.
So what makes Revit name the other end on 698364 and 1992769 is still not read. These openings pair by box, not by Tag. Nothing is written, and the RE-380 rule stays as it is.
Activity
docs: the one-project page splits the rules wrong on a second buildin…
ci(re): psets_vs_ifc lists the extra values on objects Revit does not…
DrunkOnJava commentedon Nov 14, 2026
Named, on main
8da5d029(Measure 43554418103).psets_vs_ifcnow lists, for each propertyPSETS_MISSINGnames, every object where rvt-rs writes the property and Revit does not, and whether Revit writes the object at all (branchresearch/1987-extra-valuesat3ecfe1d4). Since RE-402, the terrain files' twoPitchAnglevalues are gone. What is left:Pset_OpeningElementCommon.ReferenceIfcOpeningElementRevit's export does not write at allPset_OpeningElementCommon.ReferencePset_SlabCommon.PitchAngleCompound Ceiling:AK-4.EI60, a ceiling exported asIfcSlab: RE-238's level-slab rule, measured on floors, roofs and landings only. Draft #1992 leaves ceilings out.Pset_DoorCommon.FireRatingEI30on door type 1743417, a type object Revit writes without itSo RE-381's
Referenceis not wrong where it is written: each of these values sits on an opening Revit does not write, and the fix is the opening, not the property. That is the reverse of #1165 (openings Revit writes and rvt-rs does not). Next: why Revit writes no opening for element 1732546 in wall 1427469, and the door type's FireRating.DrunkOnJava commentedon Nov 14, 2026
On the door type's
FireRating(1743417,EI30, concrete housing at permit): the export's diagnostics for that file (43554519222) carry no "type text parameter(s) ... are left" warning, so the type's saved copies of "Fire Rating" agree. The value is what the file holds, and a stale copy (RE-431, RE-446) is not the cause. Revit's export writes the type object 1743417 withPset_DoorCommonand noFireRating, on this file only: as built and on the timber files RE-354's doorFireRatingreads equal. Next: what Revit writes on that type's doors (their ownFireRatingand the parameter it comes from), which needs this file's two exports side by side.research(re): a scorer sets a door or window type's FireRating that R…
research(re): the type FireRating scorer prints the types both export…
DrunkOnJava commentedon Nov 14, 2026
Door type 1743417's
FireRating: Revit writes it on the type in the two timber housing files and leaves it out in the concrete housing at permit. Nothing either export holds tells the files apart.A scorer on
research/1987-extra-values(tools/re/door_type_fire_rating_vs_ifc.py, at8c2087e6) lists each door or window type whosePset_DoorCommon.FireRating/Pset_WindowCommon.FireRatingrvt-rs writes. It sets every fire property of both exports beside each other, on the type and on each of its doors. Measure 43560756545, BIM4LCA housing and offices:O-2.10+4x21, RevitPset_DoorCommonwith noFireRatingEI30EI30EI30EI30EI30EI30EI30EI30EI30EI30EI30FireRatingon either sideFireRatingEI30,FireExittrue). Revit writes the type'sPset_DoorCommonin all three.FireRatingrvt-rs writes is written by Revit with the same value: 6 types as built, 5 in the timber office. That includesO-1.12x21, whose doors carryEI60against the type'sEI30.So it is the one extra
FireRatingleft on the census, and it is not a reading error: the file holdsEI30on the type, and Revit's export of a sibling project writes the same type with it.The concrete as-built file's empty row is not read yet. It is either rvt-rs writing no
FireRatingon that type there, or the type being absent from one export.Next: what the concrete files hold on that type that the timber files do not, read by a probe of the type's parameters in all four files. Until a difference is found, the value stays counted under "values Revit does not write" and nothing is narrowed.
fix(ifc): a ceiling exported as IfcSlab takes no level-slab PitchAngl…
DrunkOnJava commentedon Nov 14, 2026
Door type 1743417: what the four housing files hold.
probe_re207_element_parameterson main (Measure 43587566137) prints door 1507966 with its own parameters and its type's, in all four large housing files.Fire Ratingincluded. So is every instance parameter but one.Pset_DoorCommon.IsExternal(id 1350278), which the two timber files hold on the door and the two concrete files do not.Revit's export writes the type's
FireRatingin both timber files and leaves it out in the concrete file at permit. So the one difference in the saved parameters lines up with the export's choice, but it rests on two pairs of states of one building, and nothing ties a door'sIsExternalparameter to its type'sFireRating. No rule is written on that.A second question on our side: rvt-rs writes the type's
FireRatingin the concrete file at permit and none in the concrete file as built, from type parameters that are the same. The kept exports of the two concrete files (run 43588600114) should show which path writes the type object in each.DrunkOnJava commentedon Nov 14, 2026
Why rvt-rs writes the type's
FireRatingat permit and not as built (kept exports, run 43588600114): the door type object 1743417 carriesOtherandIdentity Datain both concrete files, andPset_DoorCommonFireRatingEI30only at permit. Neither file's diagnostics carries the RE-354 "type text parameter(s) ... are left out" warning, so no copies disagree. The type'sFireRatingcomes from the byte reader of family type table entries (partition_type_parameters, RE-354), which finds an entry for this type at permit and none as built, where the native parameter read (native_element_parameters, the probe above) finds the sameFire Ratingin both.So as built, rvt-rs matches Revit's export only because its table reader misses the entry, not because it knows to leave the value out. At permit the reader finds it, and Revit's export leaves it out. What decides Revit's choice is still not found, and the value stays counted under values Revit does not write.
research(re): a scorer says how Revit's export draws the host of each…
research(re): the opening-host scorer splits the openings both export…
DrunkOnJava commentedon Nov 14, 2026
The openings rvt-rs writes and Revit's export does not: how Revit draws their hosts. A scorer on
research/1987-extra-values(tools/re/extra_opening_hosts_vs_ifc.py, atce948168) lists each unfilled opening rvt-rs writes that Revit's export lacks, with Revit's host body, the host's openings in Revit's export and the class Revit gives the cutter. It also splits the openings both write by host body and cutter class. Measure 43589175961 and 43589555232, main32ed4e6a:Every host is a tessellated body in Revit's export. That doesn't decide it, though: of the openings both write, on tessellated hosts, Revit writes 39, 38 and 39 cut by a cabinet (office as built, permit, timber), 13, 6 and 7 by a curtain wall, 13, 21 and 1 by a door, and 25, 19 and 14 by no element it writes. So no host body and cutter class pairing separates the extras from the openings Revit writes. Six of the extras are in a host where Revit's export writes no opening at all, but that is the result, not something the file says.
No rule is written. These stay counted as the opening
Referencevalues Revit does not write, as before. A new signal would be needed to go further: the cutter's or host's native record, or Revit's tessellated host checked for whether the hole is cut into its mesh.DrunkOnJava commentedon Nov 15, 2026
Next signal, rows registered before the run is read: is the hole cut into Revit's tessellated host? A scorer on
research/1987-hole-cut(tools/re/opening_holes_vs_ifc.py,6fb94307; Measure 43691906949, the BIM4LCA office and housing onmain5f442efc) takes, for each unfilled opening rvt-rs writes, the grid points inside both the opening's body and rvt-rs's host body with no opening subtracted: the material the opening removes. It then gives the share of those points inside Revit's body of the same host, also with no opening subtracted. A share near 0 means Revit drew the hole into its body, and near 1 means it did not.A dry run on Snowdon Towers (local, against Revit's own IFC4 export) shows the measure alone does not separate. Of the openings both exports write on tessellated hosts, 10 read cut, 6 part and 6 not scored. Of the 3 extras, the one scored reads cut (0.000).
Rows:
research(re): a scorer splits the hosts of unfilled openings by Revit…
DrunkOnJava commentedon Nov 15, 2026
The hole is cut: row 3 holds, so this signal does not separate (Measure 43691906949,
opening_holes_vs_ifcat6fb94307, archived atrefs/archive/2026-11-15/cited/6fb943077fe4).IfcOpeningElementfor it. 1728679 and 1832410 (both cut by a door) have no points inside both rvt-rs's opening and its host, so they are not scored.What revit-ifc says about which openings are written (CLEANROOM.md source 5, read and cited only, at
7fe314fd):OpeningUtil.AddOpeningsToElementwrites the openingsExporterIFCUtils.GetOpeningDatareturns for the host. That call is native and cannot be read.WallSweepcutter whose category is not exported;DoorWindowDelayedOpeningCreator);WallExporter: a wall that is neither an extrusion along its axis nor a vertical extrusion of its body is given openings only if it is an in-place wall. That would predict no opening on any basic wall Revit draws tessellated. It fails on Snowdon Towers, against Revit's own IFC4 export (local, counts only), withtools/re/opening_host_kinds_vs_ifc.py(944fc015, archived). Revit's export writes 20 unfilled openings on basic walls it draws as aTessellation, and its 3 extras are on such walls too. That reading does not separate them.So which unfilled openings Revit's export writes is decided in native code. Neither the host's body, nor the cutter's class, nor whether the hole is cut tells the 10 apart from the openings it writes. The opening
Referencevalues on them stay counted as values Revit does not write, and no rule is written. Two further signals would be: the cutter's native record (what it is in the file and how it names its host), and whetherGetOpeningData's result depends on the cut's own record, the host'sm_cutListor similar, read from the bytes.DrunkOnJava commentedon Nov 15, 2026
Correction to the two comments above: Snowdon's 3 "extras" are not extras. rvt-rs's 1993286, 1993355 and 1993375 in wall 698364 are the same openings Revit's export writes as 1993278, 1993305 and 1993365. Each pair's box is equal to 0.001 ft (local, against Revit's own IFC4 export).
The Tags differ because both are lines of the wall's edited elevation profile (
CurveElemrecords of itsVarSketch1993272; probeprobe_1987_cut_idsat69a83c79, Measure 43693331497), and each export names another line of the pocket's stretch. That is RE-380's known gap: Revit names the stretch's first line on 12 of 15 pockets and its last on these 3.So this issue's openings Revit does not write are the BIM4LCA files' 10, and the Snowdon dry-run row of the hole check above is about these 3 paired openings, not extras. The rest of the hole-check result stands: all 9 of the BIM4LCA extras that could be scored are cut into Revit's body.
research(openings): a probe prints each sketch line's drawn ends, to …
DrunkOnJava commentedon Nov 15, 2026
RE-380's Tag question, one more signal ruled out: the direction a sketch line is drawn in. RE-380 checked the polygon's winding, the extrusion direction, the profile axis and the sketch list's order, but not the drawn direction of each
CurveElem'sGLine(origin + direction × each end parameter). On wall 698364 the line Revit names is the one whose drawn end is the stretch's end, so that was tested on every pocket.Probe
probe_380_sketch_line_directions(35c3ccaf, archived atrefs/archive/2026-11-15/cited/35c3ccafa3dd; Measure 43696351482), with each sketch's loop, convex hull and pockets rebuilt locally. Snowdon is read against Revit's own IFC4 export, local, counts only. Core Interior and the terrain office are read against RE-380's Tags 55859 and 1389018.The drawn direction does not decide it. On wall 698364 the lines run with the walk and Revit names the last line. On sketch 1992769 every line runs against the walk, and Revit names the last line there too. On sketches 1271797 and 2270836 the lines run with the walk, and Revit names the first.
So what makes Revit name the other end on 698364 and 1992769 is still not read. These openings pair by box, not by Tag. Nothing is written, and the RE-380 rule stays as it is.