Stair runs drawn from their sketch keep it where Revit's saved mesh exists: same box, 2.55% more volume on rac_advanced 2024 #1856
A stair run that its sketch draws (partition_stair_run_sketch) never takes its saved mesh, which replaces only record boxes. On rac_advanced 2024 the two bodies differ:
The kept exports of Measure 43325269883 give both bodies for the five runs: the saved mesh at the base, the sketch at the head. IfcOpenShell's world-coordinate shapes have the same box within 0.0001 ft. The sketch's volume is 2.55% larger on every run: 8.2973 against 8.0906 ft³ on 354390, 358394 and 360244, and 11.8273 against 11.5327 on 355864 and 357396.
On the held-out Revit 2024 model, the run the same change moves gets Revit's NetVolume and Length (Measure 43316534384). Its saved mesh had matched Revit's body (mesh bodies 1.0000). No scorer compares a sketch body to Revit's body there.
Open questions:
Which body Revit's own IFC export gives such a run. The held-out model's export answers it for one run.
Whether a run should take its saved mesh where both exist, keeping the sketch for its quantities.
Count every sketch-drawn run with a saved mesh across the corpus, and the volume gap of each, before choosing.
The count this issue asked for, read on run 43421822007 (probe_1856_sketch_runs_mesh, PR #1909): 102 models, Autodesk's 2015 to 2027 samples, the BIM4LCA files and puzzbobb's Revit 2025 models; the held-out models print nothing to a probe.
The row registered before the run holds. On rac_advanced 2024 the probe reproduces the five runs of this issue to four digits on both volumes (sketch 8.2973 and 11.8273 ft³, saved mesh 8.0906 and 11.5327), and gives the other five runs, the second of each stair, which were always drawn from their sketch: sketch 8.2973 and 11.8273, mesh 8.1041 and 11.5520 (2.38%).
The count.
240 runs in 27 models are drawn from their sketch, and every one has a saved mesh.
84 of the 240 saved scenes decode whole; 156 are partial (145 in the BIM4LCA offices and housing, 7 in rac_basic 2024 to 2027, 3 in Snowdon Towers Architectural, 1 monolithic Revit 2025 test run). A partial mesh is a fraction of Revit's body, so nothing is compared for those.
Of the 84 whole ones, the sketch's volume is equal to the mesh's (to 0.05%) on 39; 1% to 3% larger on 44 (the 40 runs of rac_advanced 2024 to 2027, 2.38% to 2.55%, and 4 in Snowdon at 2.3% to 3.0%); 3.19% larger on 1. None is smaller.
Which body Revit's export gives is not settled by what Measure holds. Snowdon's Revit export (local only, no licence) writes no quantity set for its flights, so I compared Revit's own IfcStairFlight body (IfcOpenShell, same Tag) with both volumes. 44 flights of Revit's export carry the Tag of one of the 38 Snowdon runs (six Tags are on two flights). On the 39 of them where sketch and mesh are equal (3 on partial scenes), both differ from Revit's flight by a median 3.1% (from 13.4% below to 12.4% above; 10 of the 39 by more than 5%), so that comparison cannot see a difference of 2% to 3%. On the 5 where they differ, the mesh is nearer Revit's in 4. rac_advanced has no Revit export. Percentages only here, no Revit-side volumes.
What the data does say. The mesh is the smaller wherever the two differ, by a ratio that is the same on every run of a kind (2.55% on a stair's first run, 400 triangles; 2.38% on its second, 396), and #357 records that nosing profiles are not drawn. A nosing that cuts a tread takes volume from the mesh and not from the sketch. That is a reading, not a measurement: nothing here has isolated a nosing.
What would settle it: a Revit export that carries Qto_StairFlightBaseQuantities.NetVolume for a stair whose runs have a nosing (counts and percentages are enough). Until then the body stays the sketch where one is drawn, and a run's NetVolume stays the sketch's, which the BIM4LCA offices' exports confirm. HWT-25's Revit 2027 structural model has flights (#1842): its export would answer it if it holds base quantities.
Activity
fix(ifc): a stored number past any model is read as absent where it i…
DrunkOnJava commentedon Nov 13, 2026
The count this issue asked for, read on run 43421822007 (
probe_1856_sketch_runs_mesh, PR #1909): 102 models, Autodesk's 2015 to 2027 samples, the BIM4LCA files and puzzbobb's Revit 2025 models; the held-out models print nothing to a probe.The row registered before the run holds. On
rac_advanced2024 the probe reproduces the five runs of this issue to four digits on both volumes (sketch 8.2973 and 11.8273 ft³, saved mesh 8.0906 and 11.5327), and gives the other five runs, the second of each stair, which were always drawn from their sketch: sketch 8.2973 and 11.8273, mesh 8.1041 and 11.5520 (2.38%).The count.
rac_basic2024 to 2027, 3 in Snowdon Towers Architectural, 1 monolithic Revit 2025 test run). A partial mesh is a fraction of Revit's body, so nothing is compared for those.rac_advanced2024 to 2027, 2.38% to 2.55%, and 4 in Snowdon at 2.3% to 3.0%); 3.19% larger on 1. None is smaller.Which body Revit's export gives is not settled by what Measure holds. Snowdon's Revit export (local only, no licence) writes no quantity set for its flights, so I compared Revit's own
IfcStairFlightbody (IfcOpenShell, same Tag) with both volumes. 44 flights of Revit's export carry the Tag of one of the 38 Snowdon runs (six Tags are on two flights). On the 39 of them where sketch and mesh are equal (3 on partial scenes), both differ from Revit's flight by a median 3.1% (from 13.4% below to 12.4% above; 10 of the 39 by more than 5%), so that comparison cannot see a difference of 2% to 3%. On the 5 where they differ, the mesh is nearer Revit's in 4.rac_advancedhas no Revit export. Percentages only here, no Revit-side volumes.What the data does say. The mesh is the smaller wherever the two differ, by a ratio that is the same on every run of a kind (2.55% on a stair's first run, 400 triangles; 2.38% on its second, 396), and #357 records that nosing profiles are not drawn. A nosing that cuts a tread takes volume from the mesh and not from the sketch. That is a reading, not a measurement: nothing here has isolated a nosing.
What would settle it: a Revit export that carries
Qto_StairFlightBaseQuantities.NetVolumefor a stair whose runs have a nosing (counts and percentages are enough). Until then the body stays the sketch where one is drawn, and a run'sNetVolumestays the sketch's, which the BIM4LCA offices' exports confirm. HWT-25's Revit 2027 structural model has flights (#1842): its export would answer it if it holds base quantities.research(ifc): a probe sets the volume of each stair run drawn from i…