Skip to content

Revit 2027 structural model: 104 columns, beams, slabs, flights and footings on no storey (#1829) #1842

Open

Description

@DrunkOnJava

Found by HWT-25's report (#1829) on a confidential Revit 2027 structural model (CHL), read with 0.18.0.

What happens. The storey matches Revit's export for 75% of the elements in common. 104 elements are reported as unsupported_geometry_missing_level:

class elements
IfcColumn 48
IfcBeam 25
IfcSlab 14
IfcStairFlight 14
IfcFooting 3

The diagnostics also say that 2,216 elements reached their storey through the partition Level references, with 15 storeys read.

To find out:

  • Which reference the 104 lack. A structural column has a base level, a beam a reference level. Either the reader does not read the field for these classes on 2027, or the element names no level and Revit places it by elevation.
  • Whether the same elements are on no storey in the measured models' exports. The Autodesk 2027 structural sample is one candidate.

Done when each of the 104 kinds is on Revit's storey where a record names the level, and the rest are reported.

Activity

  1. added
    area:elements
    type:bug
    on Nov 12, 2026
  2. DrunkOnJava commented on Nov 12, 2026

    @DrunkOnJava
    OwnerAuthor

    A related case on a model Measure holds: Autodesk's rstbasicsampleproject (Revit 2024 to 2027), the structural sample. Its export (Measure 43298644195, main at eaf22753) reports unsupported_geometry_missing_level on 441 elements, and none of its Level records is accepted, so its 2 storeys fall back to record-box elevations and bind 14 elements. CHL accepted 15 Level records and still had 104 elements on no storey, so the two may have different causes, but this sample can be measured where CHL cannot.

  3. DrunkOnJava commented on Nov 13, 2026

    @DrunkOnJava
    OwnerAuthor

    @HWT-25, 0.20.0 is out, and it changes the storeys this issue is about, so its numbers are worth taking again on it.

    What changed (#1867, #1868). An element on a Level whose Building Story setting is off now goes to the building story below that Level, as Revit's export places it, and a file whose Levels include no building story is written with no storey. On the models Measure scores, the elements on Revit's storey rose by 6 to 17 on each of the BIM4LCA housing files, and Autodesk's Snowdon Towers structural sample binds 824 elements to a storey where it bound 633. No model of yours is scored here, so CHL is the one place we cannot measure this ourselves.

    If you take the same comparison on 0.20.0, three counts would settle this issue, and nothing else about the model is needed:

    1. How many elements unsupported_geometry_missing_level reports now. It was 104: 48 columns, 25 beams, 14 slabs, 14 stair flights and 3 footings.
    2. The share of the elements in common that sit on the same storey as in Revit's export. It was 75%.
    3. How many of the model's Levels have Building Story switched off (the Level's properties in Revit). If some do, those Levels may be where the 104 sit.

    The #1841 schedule and the two slab answers matter more than this one, so take them first.

  4. DrunkOnJava commented on Nov 13, 2026

    @DrunkOnJava
    OwnerAuthor

    @HWT-25, one more run on CHL, counts only, and only if the first count above (unsupported_geometry_missing_level on 0.20.0) is not 0.

    The probe, built for Windows. Run 43381478427 built probe_1842_levels_named from #1878's branch (caf3fd9b). Its artifacts are at the bottom of the run page (downloading needs a GitHub login):

    • probe_1842_levels_named-gcaf3fd9b-x86_64-pc-windows-msvc: the .exe, statically linked, with SHA256SUMS and BUILT-FROM.txt beside it. macOS and Linux builds are there too.

    On the latest save:

    probe_1842_levels_named.exe CHL.rvt > levels-named.txt
    

    For each category it counts the placed instances by how many Levels their reference list names (none, one, two, three or more), and for those naming two or more, how many of those Levels lie at or below the element's box base, within the box, and at or above its top. It prints no name, no ElementId and no elevation, so the output can be posted as it is.

    Why. A record that names exactly one Level is bound to it, and one that names exactly two to its base constraint; one that names three or more matches neither rule and stays unbound. On Autodesk's samples that is 53 of 321,349 records, in structural framing, columns, stairs and walls (#1864). If CHL's 104 on no storey are records of that kind, its Structural Columns and Structural Framing lines will say so; if they name none, the cause is elsewhere and this settles that too.

  5. HWT-25 commented on Nov 13, 2026

    @HWT-25

    On 0.21.0 the three counts are unchanged from 0.18.0, and the probe output is below.

    I ran 0.21.0 rather than 0.20.0, since its notes say what is read does not change between them. Same flags as
    before; the .rvt hash is the same before and after.

    1. unsupported_geometry_missing_level: 104. Same split as before: 48 columns, 25 beams, 14 slabs, 14 stair
      flights and 3 footings.
    2. Same storey as Revit's export: 1,827 of 2,355 (77.6 %). This is against Revit's export of the same save. The
      75 % in my report was against the older export (1,451 of 1,925). 0.19.0 gives the same 1,827 against the same-save
      export.
    3. Levels with Building Story off: none. All 15 Levels have it on.

    Where the 528 others sit, by Revit's class:

    rvt-rs storey against Revit's Elements
    none 76 (48 IfcColumn, 25 IfcBeam, 3 IfcFooting)
    1 to 6 storeys lower 448 (424 IfcBeam, 21 IfcBuildingElementProxy, 2 IfcFooting, 1 IfcMember)
    1 storey higher 4 (IfcFooting)

    The probe (probe_1842_levels_named, Windows build from run 43381478427; SHA256 checked):

    file revit=2027 levels=15 records=19331 instances=18236
    levels_named Floors instances=29 n0=0 n1=29 n2=0 n3plus=0 others=0
    levels_named Generic Models instances=348 n0=336 n1=12 n2=0 n3plus=0 others=168
    levels_named Lines instances=6 n0=6 n1=0 n2=0 n3plus=0 others=0
    levels_named Lines: <Sketch> instances=2261 n0=2261 n1=0 n2=0 n3plus=0 others=0
    levels_named Stairs instances=8 n0=0 n1=0 n2=8 n3plus=0 others=0
    levels_named Stairs: Landings instances=14 n0=14 n1=0 n2=0 n3plus=0 others=0
    levels_named Stairs: Runs instances=18 n0=18 n1=0 n2=0 n3plus=0 others=0
    levels_named Structural Columns instances=822 n0=0 n1=95 n2=663 n3plus=64 others=218
    levels_named Structural Foundations instances=147 n0=88 n1=59 n2=0 n3plus=0 others=1
    levels_named Structural Framing instances=971 n0=0 n1=458 n2=487 n3plus=26 others=653
    levels_named Structural Rebar instances=13336 n0=13336 n1=0 n2=0 n3plus=0 others=38
    levels_named Walls instances=276 n0=0 n1=275 n2=1 n3plus=0 others=0
    levels_pattern Stairs named=2 at_or_below/within/at_or_above=0/1/1 instances=8
    levels_pattern Structural Columns named=2 at_or_below/within/at_or_above=0/1/1 instances=133
    levels_pattern Structural Columns named=2 at_or_below/within/at_or_above=1/0/1 instances=420
    levels_pattern Structural Columns named=2 at_or_below/within/at_or_above=1/1/0 instances=109
    levels_pattern Structural Columns named=2 at_or_below/within/at_or_above=2/0/0 instances=1
    levels_pattern Structural Columns named=3plus at_or_below/within/at_or_above=0/1/2 instances=21
    levels_pattern Structural Columns named=3plus at_or_below/within/at_or_above=1/0/2 instances=43
    levels_pattern Structural Framing named=2 at_or_below/within/at_or_above=1/0/1 instances=470
    levels_pattern Structural Framing named=2 at_or_below/within/at_or_above=2/0/0 instances=17
    levels_pattern Structural Framing named=3plus at_or_below/within/at_or_above=2/0/1 instances=26
    levels_pattern Walls named=2 at_or_below/within/at_or_above=0/2/0 instances=1
    

    What I read in it (you will know better):

    • Three or more Levels named: 64 columns and 26 framing records. On no storey: 48 columns and 25 beams. The
      counts are close but not equal, so these may be most of them.
    • The 14 flights: Runs name no Level (n0=18), which may be where they come from.
    • The 14 slabs and 3 footings: they may be among the 88 foundations that name none.
    • The beams one or more storeys lower may be a second case. 470 framing records name two Levels, one at or below
      the box and one at or above it. If they are bound to the lower Level as a base constraint, that would differ from
      Revit's export, which seems to put a beam on its Reference Level, the one at its top.
  6. DrunkOnJava commented on Nov 13, 2026

    @DrunkOnJava
    OwnerAuthor

    @HWT-25, thank you: the three counts and the probe output are what this needed. They split your 104 and your 528 into causes that can be tested on files we hold. What they say, and what runs next.

    What the numbers say.

    • Three or more Levels. 64 columns and 26 framing records name three or more Levels, and 48 columns and 25 beams are on no storey. That rule leaves a record unbound (Autodesk samples, 2025 against 2026 saves: 6 bodies, 1 profile and 12 level binds differ with no known cause #1864), so these are most of the 73 and probably the same elements. Which of the three Levels is Revit's storey is what the next run has to settle.
    • Beams one or more storeys lower. 470 framing records name two Levels, one at or below the box and one at or above it. rvt-rs binds a record that names two Levels to the lower one, its base constraint (RE-59, right for walls, columns and stairs: 650 of 650 on Snowdon Towers, 482 of 482 on Core Interior). RE-175 found that a beam's Reference Level is the highest Level its record lists, on 83 of 83 beams of the BIM4LCA timber office. Measure's own timber office shows the same mismatch today: 63 of its beams are in a different storey from Revit's, on a file we can score. Your hypothesis fits it.
    • The 14 flights and the 3 footings are not explained by this; the flights' runs name no Level, and the foundations that name none are 88. They come after.

    What runs. A probe, probe_1842_storey_rules, and its scorer, storey_rules_vs_ifc, on branch research/1842-storey-rules (71a7bef, no change to any export). For each placed instance whose record names two or more Levels the probe prints the Levels with the record box's base and top and the storey rvt-rs puts it in; the scorer sets Revit's storey beside seven rules that pick one of the named Levels, grouped by IFC entity, by how many Levels are named and by where they lie against the box. On the models Measure holds with Revit's own export: the BIM4LCA offices and housing, Core Interior, Einhoven and RE1.

    Rows, registered before the run is dispatched and before any result is read.

    1. The probe and the scorer run on every model asked for and exit 0.
    2. On each timber office file the probe lists at least 60 of the 63 beams that the storey scorer puts in a different storey from Revit's, and for them ours is not Revit's storey.
    3. On those two files the highest listed Level (hi) is Revit's storey for every beam that names two or more Levels (RE-175: 83 of 83), and the lowest Level (lo) and the base constraint (bc) are not for the 63.
    4. For every other entity that names two Levels, bc is Revit's storey for every element it gives a Level to (RE-59), and no other rule is right on more of them in any cell. A cell that shows otherwise is reported as found.
    5. For the elements that name three or more Levels and are in a storey of Revit's export, the table says which rule is Revit's, by entity. A rule is written for an entity only where one rule is right on every such element of the open models and the cell holds at least 10; the others are reported as not measured here, and your three counts on the release that follows are the check.
    6. Nothing is exported differently. The change that follows is measured unfiltered, and no model's count of elements on Revit's storey may go down.
  7. 15 remaining items

  8. HWT-25 commented on Nov 14, 2026

    @HWT-25

    The storey-rule probe on CHL: rows 1 and 2 hold, row 3 holds for the footings, row 4 is the negative, and the
    landings and flights are already in Revit's storey through their stair.

    This is a newer save than my 0.22.0 run: saved again on Revit 27.4, with Revit's export of that save. On it, 0.22.0's
    default export read by storeys_vs_ifc.py against Revit's: 2,417 elements, 51 on no storey (48 IfcColumn,
    3 IfcFooting)
    , 2,325 on Revit's storey, 27 on another (21 IfcBuildingElementProxy, 6 IfcFooting). I used the
    Windows build from run 43544251294 (SHA256 checked) and the two scripts at 0ce6c5d. The .rvt and the IFC hashes
    are the same before and after.

    The scorer's lines, as printed (without --list):

    probe: 15 levels, 15 storeys, 1849 elements listed
    totals by entity and Levels named:
      entity                 n                       N  ours        lo        hi       hi*        bc     <base      =top      <top      >top      only      top*     base*       r2l
      IFCBEAM                1                     453   453  453/453     0/0       0/0       0/0     453/453     0/0     158/158   295/295   453/453     0/50    138/453   453/453
      IFCBEAM                2                     436   436    0/436   436/436   436/436    11/436    11/436    12/12     23/436   425/425     0/0      12/312    11/436   436/436
      IFCBEAM                3+                     25    25    0/25     25/25     25/25      0/0       0/25      0/0       0/25     25/25      0/0       0/21      0/25     25/25
      IFCCOLUMN              1                      74    74   74/74      0/0       0/0       0/0      74/74      0/0      74/74      0/0      74/74      0/0      73/74     74/74
      IFCCOLUMN              2                     598   598  597/598     1/598     1/423   598/598   598/598     0/146   388/598     0/533     0/0       0/154   487/598     1/598
      IFCCOLUMN              3+                     48     0   48/48      0/48      0/27      0/0      48/48      0/28     20/48      0/48      0/0       0/28     27/48      0/48
      IFCFOOTING             0                      88    79    0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0      88/88      0/0
      IFCMEMBER              2                       1     1    0/1       1/1       1/1       0/1       0/1       0/0       0/1       1/1       0/0       0/1       0/1       1/1
      IFCSLAB                0                      14     0    0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/14      0/0
      IFCSLAB                1                      85    85   85/85      0/0       0/0       0/0      85/85     39/39     85/85     39/39     85/85     39/40     45/81     85/85
      IFCSTAIR               2                       8     8    8/8       0/8       0/1       8/8       8/8       0/1       7/8       0/8       0/0       0/1       1/8       0/8
      IFCSTAIRFLIGHT         0                      18     1    0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/1       1/18      0/0
      IFCWALL                2                       1     1    1/1       0/1       0/0       1/1       1/1       0/0       0/1       0/0       0/0       0/0       0/1       0/1
    

    (The per-pattern table above it is in the same file; for the 48 columns it splits into 27 with the Levels at
    1/0/2 and 21 at 0/1/2, and lo and <base give 27/27 and 21/21.)

    The rows:

    1. Holds. The probe exits 0 on the save (29 s) and the scorer reads Revit's export of it. Nothing is left out.
    2. Holds. For the 48 columns that name three or more Levels, lo and <base put 48 of 48 in Revit's storey;
      base* 27, <top 20.
    3. Holds for the footings, not for the 14 "slabs". base* puts 88 of 88 footings in Revit's storey, the 3 on
      no storey and the 6 on another storey among them. The 14 IfcSlab that name no Level are stair landings
      (category Stairs: Landings), not foundation slabs, and base* puts none of them in Revit's storey.
    4. The negative. No rule puts the 18 stair flights in Revit's storey (base* 1 of 18).

    What I read in it (you will know better):

    • The landings and flights are not on a wrong storey in the IFC. In Revit's export the 18 IfcStairFlight and the
      14 landing IfcSlab have no containment of their own: each is a part of its IfcStair through IfcRelAggregates,
      and the stair is contained in the storey. rvt-rs 0.22.0 writes them the same way, and puts all 8 IfcStair in
      Revit's storey (ours 8/8 above), so storeys_vs_ifc.py gives all 32 Revit's storey through their stair. That is
      why they are not among the 51 above. The ours = - the probe prints for them is the storey of the part itself.
      So for them the rule is "the stair's storey", which the export already follows; whether the storey warning should
      count parts carried by their stair as on no storey is your call.
    • What lo and base* would leave: with lo for the 48 columns and base* for the 9 footings, the 51 on no
      storey would go to 0, and of the 27 on another storey 21 IfcBuildingElementProxy would remain, which are outside
      the probe's classes.

    The ElementIds and the Level names stay on my machine; I can say more by count if a cell needs it.

  9. DrunkOnJava commented on Nov 14, 2026

    @DrunkOnJava
    OwnerAuthor

    @HWT-25, thank you for this run. Scored against the rows I registered on 11-14:

    1. Holds. The probe exits 0 and the scorer reads Revit's export of your save.
    2. Holds. For the 48 columns that name three or more Levels, <base and lo each put 48 of 48 in Revit's storey (<base is the highest named Level at or below the box's base, else the lowest).
    3. Holds for the footings, not for the 14 "slabs". For the 88 footings that name no Level, base* (the highest building-story Level of the model at or below the box's base) puts 88 of 88 in Revit's storey, the 3 on no storey and the 6 on another among them. The 14 IfcSlab that name none are stair landings, which base* puts in none (0 of 14).
    4. The negative holds, and needs no rule. base* puts 1 of 18 flights in Revit's storey, but your reading is right: rvt-rs writes the flights and landings as parts of their IfcStair, as Revit's export does, and the stairs are in Revit's storey (8 of 8).

    The 28 in the diagnostics are a miscount, not a storey. unsupported_geometry_missing_level counts every element whose own storey is empty, parts of a stair included, so the 14 landings and 14 flights of your 79 were never on no storey. That count is fixed separately, output-neutral for the IFC.

    What ships from the rest. Two rules, each in a change of its own with a Measure on the models we hold: <base for a column that names three or more Levels, and base* for a footing that names none. Both rest on your model alone (no model of ours with Revit's export holds either case), so they apply to Revit 2027 only, the release of your save (RE-353), are listed under "Rules that rest on one project", and mark each element they place on its LevelBindSource, so they are counted apart. The 21 IfcBuildingElementProxy on another storey are outside the probe's classes and stay open.

  10. DrunkOnJava commented on Nov 14, 2026

    @DrunkOnJava
    OwnerAuthor

    @HWT-25, the two rules are in draft #2013 (RE-469), for Revit 2027 only: a column that names three or more Levels takes <base, and a footing that names none takes base*. Could you run the build of that head on the same save you used for the last table, and post the scorer's lines? Only counts leave your machine.

    1. Download the Windows build from this run: probe_1842_storey_rules-gdbfbe6b1-x86_64-pc-windows-msvc, with its SHA256SUMS (it is the build of dbfbe6b1; the probe runs rvt-rs's own export, so its ours column is the storey the new rules give).
    2. probe_1842_storey_rules.exe CHL.rvt > storey.txt, then python tools/re/storey_rules_vs_ifc.py storey.txt <Revit's export of that save>.ifc, with the scorer from main as before (the scorer is unchanged). Post the lines without --list.

    Rows, registered before you run it.

    1. The probe exits 0 on the save and the scorer reads Revit's export of it.
    2. The 48 IfcColumn that name three or more Levels read ours 48 of 48 (the ours cell of the IFCCOLUMN 3+ row is 48; it was 0).
    3. The 88 IfcFooting that name no Level read ours 88 of 88 (it was 79).
    4. No other row's ours changes: the beams, the other columns, the slabs, the stairs and the walls read the same as in your last table.

    If a row fails, that is the result, and the rule is changed or withdrawn before it lands.

  11. added
    priority:P2
    on Nov 14, 2026
  12. HWT-25 commented on Nov 15, 2026

    @HWT-25

    #2013 on CHL: all four rows hold.

    Same save and same export as my last table, with the Windows build of dbfbe6b1 from run 43593171560 (SHA256
    checked) and the scorer from main. The .rvt and the IFC hashes are the same before and after.

    probe: 15 levels, 15 storeys, 1849 elements listed
    totals by entity and Levels named:
      IFCBEAM                1                     453   453  453/453     0/0       0/0       0/0     453/453     0/0     158/158   295/295   453/453     0/50    138/453   453/453
      IFCBEAM                2                     436   436    0/436   436/436   436/436    11/436    11/436    12/12     23/436   425/425     0/0      12/312    11/436   436/436
      IFCBEAM                3+                     25    25    0/25     25/25     25/25      0/0       0/25      0/0       0/25     25/25      0/0       0/21      0/25     25/25
      IFCCOLUMN              1                      74    74   74/74      0/0       0/0       0/0      74/74      0/0      74/74      0/0      74/74      0/0      73/74     74/74
      IFCCOLUMN              2                     598   598  597/598     1/598     1/423   598/598   598/598     0/146   388/598     0/533     0/0       0/154   487/598     1/598
      IFCCOLUMN              3+                     48    48   48/48      0/48      0/27      0/0      48/48      0/28     20/48      0/48      0/0       0/28     27/48      0/48
      IFCFOOTING             0                      88    88    0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0      88/88      0/0
      IFCMEMBER              2                       1     1    0/1       1/1       1/1       0/1       0/1       0/0       0/1       1/1       0/0       0/1       0/1       1/1
      IFCSLAB                0                      14     0    0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/14      0/0
      IFCSLAB                1                      85    85   85/85      0/0       0/0       0/0      85/85     39/39     85/85     39/39     85/85     39/40     45/81     85/85
      IFCSTAIR               2                       8     8    8/8       0/8       0/1       8/8       8/8       0/1       7/8       0/8       0/0       0/1       1/8       0/8
      IFCSTAIRFLIGHT         0                      18     1    0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/0       0/1       1/18      0/0
      IFCWALL                2                       1     1    1/1       0/1       0/0       1/1       1/1       0/0       0/1       0/0       0/0       0/0       0/1       0/1
    
    1. Holds. The probe exits 0 and the scorer reads Revit's export.
    2. Holds. IFCCOLUMN 3+ reads ours 48 (was 0): 27 at 1/0/2 and 21 at 0/1/2, all in Revit's storey.
    3. Holds. IFCFOOTING 0 reads ours 88 (was 79).
    4. Holds. Against my last table, the only lines that change in the whole output are those five (the two
      per-pattern column rows, the footing row and their two totals). Every other row reads the same.

    The landings and flights still read ours 0 and 1, as before: they are parts of their stair, as you said.

  13. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    @HWT-25, thank you: all four rows registered before your run hold, so the two rules stay as they are in #2013.

    1. Holds. The probe exits 0 and the scorer reads Revit's export.
    2. Holds. IFCCOLUMN 3+ reads ours 48 (was 0), 27 and 21 in the two patterns the table splits them by, all in Revit's storey.
    3. Holds. IFCFOOTING 0 reads ours 88 (was 79).
    4. Holds. Against your last table the only lines that change are the five you name.

    What it settles on your save: the 48 columns and 3 footings that 0.22.0 left on no storey are in Revit's storey under these rules, and so are the 6 footings that were in another. The landings and flights still read ours 0 and 1, as you read it: they are parts of their stair. What is left of this issue on your save is the 21 IfcBuildingElementProxy in another storey than Revit's, which #2013 does not touch.

    The two rules rest on your model alone (no model of ours with Revit's export holds either case), so they apply to Revit 2027 only, are listed under "Rules that rest on one project", and each element they place says so in its LevelBindSource. #2013 is out of draft with these counts in RE-469; it lands after a second read and green CI, and goes out with the next release. Only the counts you posted are in it, nothing from your file.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:elementspriority:P2type:bug

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions