You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Concrete housing at permit: two wall ends that were exact are 0.27 and 0.29 m off once the walls' types have their layers (1347019, 1347016) #1806
Once a wall's type has its layers (RE-446, #1802) the wall takes the body its layers allow, and on the BIM4LCA concrete housing at building permit three walls of the types US-3 and US-4 trade an exact end for a nearer worst end (tools/re/wall_ends_list.py, Measure run 43155545709, main against the change; shortfall of rvt-rs's wall against Revit's at the start and the end, in feet):
wall
on main (partition_element_record_join_trimmed)
with the layers
1347019 US-4
start +1.3780, end 0.0000
start +0.4429, end -0.9350 (partition_wall_centreline)
1347016 US-3
start 0.0000, end +1.2795
start +0.8858, end +0.3937 (partition_wall_centreline)
1426918 US-4
start +1.3780, end +1.2795
both ends under 0.84 (not among the 40 listed)
1347023 US-4
start +1.3780, end +1.3780
start 0.0000, end +1.3780 (partition_wall_centreline_layer_joins)
The scorer's rows only improve (walls with both ends within 0.001 ft 274 of 345 before and after, the worst end within 1.0 ft 322 to 325, faces across 345 of 345) and tools/re/cmp_measure.py lists no body regression, but the two ends of 1347019 and 1347016 that were exact are now 0.935 and 0.886 ft (0.285 and 0.270 m) off. Wall 1347019 records JoinTrimStart and JoinTrimEnd of 0.285 m both on main and with the layers; whether the line path applies them is not known. Revit's joins at the ends the scorer lists are empty.
Done when
The cause is told (the line longer than the body at an end the box cut, or a join the line path does not apply), and the two ends are exact again with no other end of the three walls worse than the table, or the walls keep the path they had before and the rule that moves them is narrowed so it is never worse. The timber office at permit's five walls whose ends moved by 18 mm (3067189, 3067298, 3071333, 3094656, 3119857) improve the scorer's ends (311 to 316 of 586 within 0.001 ft) and are not part of this.
Read from the two exports of Measure 43155545709 (keep_ifc, PR #1807), before any reading of the code path:
1347019 (US-4, thickness 0.54 m, JoinTrimStart and JoinTrimEnd 0.285 on main and with the layers): the body along the wall is 4.310 m on main (partition_element_record_join_trimmed) and 4.880 m with the layers (partition_wall_centreline), longer by 0.570 m, the sum of its two join trims. The start moves out by 0.285 m (shortfall +1.3780 to +0.4429 ft) and the end by 0.285 m past Revit's (0.0000 to -0.9350 ft).
1347016 (US-3, thickness 0.57 m, JoinTrimStart 0.0, JoinTrimEnd 0.27): the body is 26.903 ft long on both, and with the layers it is shifted along the wall by 0.8858 ft (0.27 m, its JoinTrimEnd): the start goes from exact to 0.8858 ft short, the end from 1.2795 to 0.3937 ft short.
So the move equals the join trims the box path applies and the line path (wall_centreline_body, "an axis-parallel wall keeps the box's extent, which its joins trimmed") does not, or applies at the other end. That is a reading of the numbers, not of the code: the next step is a probe of the two paths on 1347019 and 1347016 against Revit's ends (wall_ends_list.py --list 400 on the housing at permit, which prints every wall, not the 40 largest shortfalls).
Folded into #1814, which now lists these two ends as acceptance rows. RE-447 (#1822) measured them: neither the record box's ends nor the line's are Revit's at every end of such a wall, and no per-end rule read from its joins picks right everywhere.
Activity
DrunkOnJava commentedon Nov 12, 2026
Read from the two exports of Measure 43155545709 (
keep_ifc, PR #1807), before any reading of the code path:US-4, thickness 0.54 m,JoinTrimStartandJoinTrimEnd0.285 onmainand with the layers): the body along the wall is 4.310 m onmain(partition_element_record_join_trimmed) and 4.880 m with the layers (partition_wall_centreline), longer by 0.570 m, the sum of its two join trims. The start moves out by 0.285 m (shortfall +1.3780 to +0.4429 ft) and the end by 0.285 m past Revit's (0.0000 to -0.9350 ft).US-3, thickness 0.57 m,JoinTrimStart0.0,JoinTrimEnd0.27): the body is 26.903 ft long on both, and with the layers it is shifted along the wall by 0.8858 ft (0.27 m, itsJoinTrimEnd): the start goes from exact to 0.8858 ft short, the end from 1.2795 to 0.3937 ft short.So the move equals the join trims the box path applies and the line path (
wall_centreline_body, "an axis-parallel wall keeps the box's extent, which its joins trimmed") does not, or applies at the other end. That is a reading of the numbers, not of the code: the next step is a probe of the two paths on 1347019 and 1347016 against Revit's ends (wall_ends_list.py --list 400on the housing at permit, which prints every wall, not the 40 largest shortfalls).fix(elements): a wall, floor, ceiling or roof type edited since an ea…
fix(ifc): take the box's extent at the line's own angle for a wall th…
DrunkOnJava commentedon Nov 12, 2026
Folded into #1814, which now lists these two ends as acceptance rows. RE-447 (#1822) measured them: neither the record box's ends nor the line's are Revit's at every end of such a wall, and no per-end rule read from its joins picks right everywhere.
docs(re): RE-447 finds neither the record box's nor the line's ends r…