You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Timber office at permit: mullions 3028901 and 3028902 lose their NetSurfaceArea once a neighbour keeps its newest frame (RE-444) #1803
With RE-444 (#1799, Measure 43139762399) two mullions of the BIM4LCA timber office at building permit, 3028901 and 3028902 (0.1 m pieces), no longer get a Qto_MemberBaseQuantities.NetSurfaceArea, where main wrote Revit's value (equal to Revit's in both). The mullions' own frame is the one kept before and after: each is framed in Partitions/374 and 424, their frames differ in plan only (0.36171 by 0.24280 ft in 374 against 0.36106 by 0.24043 in 424 for 3028901; 0.35897 by 0.23323 against 0.35823 by 0.23080 for 3028902) and the vertical extent is 0.16404 ft in both, so the greater extent was already the newest. So what changed is not their own frame but a neighbour's: the ends rule (RE-436, RE-438, RE-441) reads the boxes of the mullions beside a piece, and a neighbour framed in several partitions now keeps its newest frame.
Over the file the change is a gain: the mullions' NetSurfaceArea equal rises 7,629 to 7,745 and missing falls 242 to 127 (the neighbours of the mullions with a stale frame are read right), and 3029161, which depended on its stale partner 3029162, is now equal (#1767). These two are the ones that went the other way. Which neighbour, and what its newest frame changes at the end, is not read.
The neighbour whose frame moved is named, with both frames' boxes, and the rule that now leaves the two mullions out is told apart from the ones that still hold, or recorded as a measured negative with the counts.
Both mullions' NetSurfaceArea is Revit's again, or the miss is stated and none of the other mullions' values differ from Revit's.
A lead, read from the two MCP dumps and the export of Measure 43139762399 (nothing run since):
The two pieces are two of a chain of eight 0.1 m pieces, 3028897 to 3028904, each about 0.37 by 0.28 by 0.164 ft, which start at z 194.06168 ft and stand on the top of a vertical 50 by 50 mm mullion, 3027086. In plan the vertical mullion is 0.049 ft from each of 3028901 and 3028902 (at 104.0162, 1.0189 against 104.0647, 1.0312 and 103.9674, 1.0082 ft); the other six pieces lie further along the chain, 0.1 ft apart. 3027086 is the only mullion within 0.4 ft of the chain whose kept frame moved between main and #1799:
frame
box (ft)
min z
top z
Partitions/374/8416398 (kept on main)
0.19836 by 0.19836 by 14.00919
180.05249
194.06168
Partitions/424/2860835 (newest, routed; kept in #1799)
0.19733 by 0.19733 by 13.84514
180.21654
194.06168
Its top end, where the pieces start, is the same in both frames; its foot is 0.164 ft higher and its plan box 1 mm narrower. The pieces' own frames are unchanged (Partitions/424 before and after). So the two pieces that lose their NetSurfaceArea are the two that stand on a mullion whose frame changed, and the other six keep theirs.
Next: read which end test of RE-436, RE-438 or RE-441 these two pieces pass with 3027086's old frame and fail with its newest (the 1 mm in plan, or the foot), and whether Revit's value for them is what the old frame gives by chance or by the rule.
Activity
DrunkOnJava commentedon Nov 12, 2026
A lead, read from the two MCP dumps and the export of Measure 43139762399 (nothing run since):
The two pieces are two of a chain of eight 0.1 m pieces, 3028897 to 3028904, each about 0.37 by 0.28 by 0.164 ft, which start at z 194.06168 ft and stand on the top of a vertical 50 by 50 mm mullion, 3027086. In plan the vertical mullion is 0.049 ft from each of 3028901 and 3028902 (at 104.0162, 1.0189 against 104.0647, 1.0312 and 103.9674, 1.0082 ft); the other six pieces lie further along the chain, 0.1 ft apart. 3027086 is the only mullion within 0.4 ft of the chain whose kept frame moved between
mainand #1799:Partitions/374/8416398(kept onmain)Partitions/424/2860835(newest, routed; kept in #1799)Its top end, where the pieces start, is the same in both frames; its foot is 0.164 ft higher and its plan box 1 mm narrower. The pieces' own frames are unchanged (
Partitions/424before and after). So the two pieces that lose theirNetSurfaceAreaare the two that stand on a mullion whose frame changed, and the other six keep theirs.Next: read which end test of RE-436, RE-438 or RE-441 these two pieces pass with 3027086's old frame and fail with its newest (the 1 mm in plan, or the foot), and whether Revit's value for them is what the old frame gives by chance or by the rule.
fix(elements): of an element framed in several partitions the exporte…
fix(elements): a wall, floor, ceiling or roof type edited since an ea…
fix(ifc): test the far-end case, and say the gain is 4 mullions in ea…
fix(ifc): a mullion overlapped at its far end does not leave out the …