Autodesk rme samples, 2025 to 2027 saves: 131 columns in each hold a Length (3.5, 7.3, 10.6 or 7.0 m) that is not their mesh's extent, which the 2024 saves give #1801
On the 2025, 2026 and 2027 saves of Autodesk's rme_advanced_sample_project and rme_basic_sample_project, 131 columns in each of the six files hold a Qto_ColumnBaseQuantities.Length that is not the extent of the mesh Revit saved for them: 46 columns hold 3.5 m for a mesh of 3.405828 m, 41 hold 7.3 m for 3.5 m, 41 hold 10.6 m for 3.3 m and 3 hold 7.0 m for 3.2 m. The 2024 saves of the same two projects, with the same ElementIds and the same meshes, hold the meshes' extents (3.405828, 3.5, 3.3 and 3.2 m). No Revit export covers these files, so this is a disagreement between two saves of one project, not a measured error; but a project saved again does not change its columns' heights.
Found with tools/re/length_vs_mesh_extent.py (RE-444, #1799) on the 101 exports Measure 43115049478 kept: a written Length is never shorter than the mesh by 2 mm anywhere, and is longer on these 786 columns and on 5 elements of the BIM4LCA timber office at permit.
Not the frame choice
The 5 BIM4LCA elements were the exporter keeping an older frame of an element framed in several partitions (RE-444); the same change leaves these 12 exports byte for byte as they were (Measure 43139762399), so the Length of these columns is not a choice between frames. The BoundingBoxHeight the export records for the first of them, 573295 (STB Stütze - rund : STB d=30), is 3.405828 in the 2024 save and 3.5 in the 2025 one, and the column is drawn from its saved mesh (BodySourcesaved_graphics_mesh), which is 3.405828 tall in both. Round columns have a mesh with curved faces, so column_quantities (RE-424) does not read them and their Length is the record box's alone.
Done when
The record of a 2025 to 2027 save that gives these columns a box 3.5, 7.3, 10.6 or 7.0 m tall is read: where the height comes from (a level offset, a stacked arrangement, another field), against the 2024 save's.
The 131 columns of each save hold the 2024 save's Length, or none; the six files are held to their 2024 saves by a gate or a scorer that sets the quantities of one project's saves against one another.
Activity
fix(elements): of an element framed in several partitions the exporte…
docs(ifc): the column Length rule says what RE-444 found, which relea…
ci(measure): the same-project gate holds every column's Length to the…
fix(ifc): a column drawn from its saved mesh takes the mesh's height …