Mullion NetSurfaceArea: 2 values one end face short on the timber office as built and 6 at permit #1745
After RE-432 (PR #1739, Measure run 43054102602) the BIM4LCA timber office still has Qto_MemberBaseQuantities.NetSurfaceArea values that differ from Revit's: 2 as built and 6 at permit. The two as built are mullions 1912157 (rvt-rs 0.0200 m², Revit 0.0225) and 1912158 (rvt-rs 0.0400, Revit 0.0475, a 150 x 50 section): each is one end face short (0.0025 and 0.0075 m²), so rvt-rs hides one end more than Revit counts as hidden. They have no partner bent off the axis, so RE-432 does not touch them. The 6 at permit are the same kind (their tags are not listed: the census gives counts).
Why
Not read yet. Candidates: RE-268 hides an end for a reason Revit's solid does not hold (a mullion of 0.1 and 0.15 m across a corner), or the kept count comes from a continuation on another curtain wall (RE-404's partner check covers one). RE-403 left 5 mullions wrong at permit by the same kind of reading.
Done when
A probe over these mullions (kept ends, what lies at each end, Revit's value) says what separates them from the thousands that are equal.
The rule is narrowed until none is wrong, measured with the pair of states and the concrete office, and what it leaves out is reported.
Activity
fix(ifc): a continuation bent off a mullion's axis does not hide its …
docs(re): RE-436's Measure result: the timber office's 2 NetSurfaceAr…
fix(ifc): a continuation of another section hides no end face of a cu…