Mullion NetSurfaceArea: 2 values one end face short on the timber office as built and 6 at permit #1745

Closed

Description

@DrunkOnJava

What

After RE-432 (PR #1739, Measure run 43054102602) the BIM4LCA timber office still has Qto_MemberBaseQuantities.NetSurfaceArea values that differ from Revit's: 2 as built and 6 at permit. The two as built are mullions 1912157 (rvt-rs 0.0200 m², Revit 0.0225) and 1912158 (rvt-rs 0.0400, Revit 0.0475, a 150 x 50 section): each is one end face short (0.0025 and 0.0075 m²), so rvt-rs hides one end more than Revit counts as hidden. They have no partner bent off the axis, so RE-432 does not touch them. The 6 at permit are the same kind (their tags are not listed: the census gives counts).

Why

Not read yet. Candidates: RE-268 hides an end for a reason Revit's solid does not hold (a mullion of 0.1 and 0.15 m across a corner), or the kept count comes from a continuation on another curtain wall (RE-404's partner check covers one). RE-403 left 5 mullions wrong at permit by the same kind of reading.

Done when

  • A probe over these mullions (kept ends, what lies at each end, Revit's value) says what separates them from the thousands that are equal.
  • The rule is narrowed until none is wrong, measured with the pair of states and the concrete office, and what it leaves out is reported.

Related

#1735, #1046, RE-268, RE-403, RE-432.