W7: the housing's columns drawn as their record box get no CrossSectionArea, OuterSurfaceArea or GrossVolume, though the box's values equal Revit's on 46 of 50 (timber) and 4 of 4 (concrete) #1705
After RE-424 (reports/element-framing/RE-424-column-base-quantities.md, a column drawn from a saved mesh gets Length, CrossSectionArea, OuterSurfaceArea and GrossVolume from the prism its mesh is) the largest group of extruded columns that still lack CrossSectionArea, OuterSurfaceArea and GrossVolume is the one rvt-rs draws as its record box (BodySourcepartition_element_record_bbox): the BIM4LCA timber housing's 50 of 54 columns in each state, 4 of the concrete housing's 7 and 4 of 5 in each of its terrain files. Revit's export writes all four on every one of them.
Measured (Measure 42986667074, tools/re/column_quantities_vs_ifc.py, which reads rvt-rs's own box as the beam rule reads a mesh): the box's values equal Revit's CrossSectionArea, OuterSurfaceArea, GrossVolume and NetVolume on 46 of the timber housing's 50 box columns and on 4 of 4 of the concrete housing's, and differ from Revit's on the other 4 of the timber housing; the box's height equals Revit's Length on the 29 (timber) and 2 (concrete) columns that lack it. The shipped census has rvt-rs equal on none of the three on any of the 54 timber housing columns (CrossSectionArea 0 of 54), and Length equal on 25 of 54.
Not known. Why RE-291's rule (src/ifc/export_content/column_quantities.rs) writes none of them here. It writes the box's quantities for a column whose type is a plain rectangle (parameters b, or h and b, equal to the box's sides) and which nothing cuts or joins across an end; its type test and its join test have not been read against these columns. The 4 timber housing columns whose box differs from Revit's have to be told apart first.
Next. A probe of RE-291's refusal on these columns, the rule narrowed to where the box is the solid (rows on #1636 before the run is read), Length on the 31 that lack it, and a Measure.
Also left by RE-424. The BIM4LCA timber office at permit holds a Length on 2 columns that differs from Revit's while the extent of their mesh equals it; a value a column holds is never replaced, so they stay. Whether a mesh extent may replace a held Length when the two disagree is the question.
For scale (RE-424's sample cross-check, tools/re/column_added_quantities.py over the head exports of Autodesk's samples, no Revit export to score them): 2,727 columns of 31 samples are drawn as their record box and hold none of the four quantities, and 139 of 9 samples hold one. Whether Revit writes the four on them is not known, and the BIM4LCA housing's data above is the measurement this issue rests on; the samples say only how many columns a box rule would touch.
Activity
DrunkOnJava commentedon Nov 11, 2026
For scale (RE-424's sample cross-check,
tools/re/column_added_quantities.pyover the head exports of Autodesk's samples, no Revit export to score them): 2,727 columns of 31 samples are drawn as their record box and hold none of the four quantities, and 139 of 9 samples hold one. Whether Revit writes the four on them is not known, and the BIM4LCA housing's data above is the measurement this issue rests on; the samples say only how many columns a box rule would touch.feat(ifc): a column whose mesh is a vertical prism gets the Length, C…
docs(re): RE-425 reports the housing's rectangle columns taking their…
merge: main into feat/1705-box-column-quantities (#1705)
feat(ifc): a column drawn as its type's rectangle gets the base quant…