Skip to content

W7: beams' base quantities: rvt-rs writes Length on the beams drawn along their line and none of the other six, on 300 beams of the BIM4LCA files #1693

Closed

Description

@DrunkOnJava

Part of W7 (#1016). Evidence: the qtos_vs_ifc and diagnostics.json outputs of Measure 42950801466 (every flag, 126 models).

Not written

Revit's export writes Qto_BeamBaseQuantities with CrossSectionArea, GrossSurfaceArea, GrossVolume, NetSurfaceArea, NetVolume and OuterSurfaceArea on every beam of the BIM4LCA models: 22 on each concrete housing file, 41 on each timber housing file, 8 on each office file and on each terrain housing file, 71 on each timber office file, 300 beams in all, so 1,800 values. rvt-rs writes none of them (equal 0, missing 300 on each of the six lines). Length it writes on the beams drawn along their location line, equal to Revit's on 64 of the timber office at permit's 71; the other 7 are drawn from saved meshes and carry no Length.

Why

add_beam_length leaves the areas and volumes out because a partition_beam_axis body is the box along the beam's line, not its section. 218 beams over the BIM4LCA large files, Core Interior, Einhoven and RE1 have that body source. saved_meshes::is_replaceable_box offers the pass the record's box, a beam's box (partition_beam_box_along_axis) and a turned box (an oriented box with #1689), but not partition_beam_axis: the mesh Revit saved for these beams is never read, their bodies are not scored against Revit's (box_bodies_vs_ifc lists none), and no SavedMeshRefusal says why.

Candidate

  1. Offer partition_beam_axis to the saved-mesh pass and measure the bodies against Revit's.
  2. Write the six quantities from the mesh where it is a prism along the beam's axis (RE-418's extent_along and RE-404's prism_along read exactly that: the end area is the cross section, the lateral area the outer surface, the volume the net volume), after a scorer reads which of Revit's six are those sums. revit-ifc's CreateBeamColumnBaseQuantities (CLEANROOM.md source 5, as RE-353 read it) takes a column's from the extrusion's profile and length, and a beam is exported by the same function; a beam Revit draws as a cut mesh takes the mesh's.

Done when: each of the six lines reads equal for every beam whose mesh decodes whole, with no different and holdout=true read first; or the report names the beams it cannot tell and why.

Related: #1016, #94 (the sections of structural framing), #1203 (columns, the same revit-ifc function), #1689, RE-353, RE-404, RE-418.

Activity

  1. added
    area:ifc
    priority:P2
    type:feature
    on Nov 11, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:ifcpriority:P2type:feature

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions