You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
List the shipped rules that rest on one project, and the second model that could test each #1636
Some shipped rules rest on one project (or one element in it), so no other file has tested them. A held-out pair of the same release cannot test a rule nobody has listed. This issue lists the rules, and next to each the held-out or second model that could test it, or "none".
First list (a grep of reports/element-framing/RE-*.md for statements of one model; it misses any report that does not say so in words)
Confirmed by the report's own sentence:
RE-390: the component rule rests on one railing (Tag 2598405), one in each of two saves of one project (the BIM4LCA office).
RE-79: "The nested rule is measured on one model."
RE-216: the opening check is one stacked pattern on one model; the office's 10 doors are checked through their type GlobalIds only.
RE-358: the edited-profile cut-out rests on the office's six high ends and two low ends (one project, one wall type, one stretch length).
RE-181: the 2014 row rests on one project whose origin is not documented (2014 is not read).
Plate Width (RE-396, rvtDevelop's pull request, not yet landed): the rule is measured on the office only, the one model with plate quantities.
Matched the grep, not yet read for the claim: RE-254, RE-330, RE-375.
Done when
Every row has either a second model that exercises the rule (named, with the Measure run that scores it) or a written "none exists", and the "none" rows are the list of what a new reference model should be asked for (#408, the pairs asked of contributors). Whether a rule that rests on one project may ship at all is the project owner's call; this list is what that call needs.
One more row, from the review of #1629 (RE-388): the "four or fewer vertical faces" gate that decides which walls get NetSideArea, GrossSideArea and GrossVolume beyond NetVolume is fitted on one project (the BIM4LCA office: none of its 26 volume-only walls is a plain prism). It stands in for a decision inside Revit's own exporter: revit-ifc (tag IFC_v24.1.0, read for facts only) writes the full wall quantity set only for a wall it exports as an extrusion with an axis, and a wall exported as a BRep gets NetVolume alone. A counts-only scorer on the 26 volume-only walls, checking them against the body item classes in Revit's own export, is running (Measure 42862248369). If the classes match, the gate has a reason beyond one project and this row can go; if not, it needs a second model.
Result for the wall-quantity gate row above (Measure 42862248369, a counts-only scorer): the hypothesis that Revit's exporter writes the full wall set only for walls it draws as an extrusion did not hold. On the BIM4LCA office Revit writes GrossSideArea, NetSideArea and GrossVolume on 304 walls drawn as polygonal face sets and 275 drawn as extrusions, and NetVolume alone on 27 face-set walls and 1 extruded one. So the 26 walls that get a volume only are not explained by how Revit draws them, and RE-388's "four or fewer vertical faces" gate stays an empirical proxy resting on one project. The row stays: it needs a second model with Revit's wall quantities, or a reading of what else decides it.
Rows added after reading the three reports the grep matched, and one that landed since the list was written.
RE-254 (a stair railing's Length): not a single-project row. Its third rule is measured on the BIM4LCA office (Revit 2024) and on puzzbobb's R2025 13 to 16 (Revit 2025), two projects (RE-254 section 4).
RE-330 (Areas from their boundary lines): one project. 16 of the 25 Areas of Autodesk's rac_advanced, saves 2015 to 2024, with one external check, an IFC2X3 export of the project's 2020 state (RE-330 section 0). Second model: none, since no Revit IFC4 export of an Area exists (RE-330 section 6).
RE-375 (a wall's stub cut whole): one wall. The stub of 3004978 on the office; no piece of any other model is in the class the rule separates (RE-375 section 5). Second model: none.
The "none" rows so far all ask for the same thing: a Revit 2024 or later model with curtain walls and walls whose own IFC4 export holds base quantities (#408).
The wall-quantity gate row (RE-388's four-or-fewer-vertical-faces rule) now has its report: RE-399 (docs(re): RE-399 finds nothing in Revit's bodies or the saved graphics that tells the walls and mullions Revit leaves quantities off (#1046) (RE-399) #1646). Revit's own body class and voiding do not tell the 28 volume-only walls (24 at permit) from the full-set walls on the office, and the 24 Revit 2025 models hold no volume-only wall at all (138 of 138 full set), so the gate is still a one-project proxy. What would settle it is a model with Revit's wall quantities that holds walls with five or more vertical faces; none of the models Measure fetches has one. RE-399 also records that the same check on columns reproduces RE-291 from Revit's side, and that no visibility or filter flag marks a mullion's end faces.
Pre-registration: the BIM4LCA Housing and Office Timber measurement
Posted before any run on these models. Nothing below is tuned to their results: it names, for each shipped rule that the reports say rests on one project, what "holds on the Housing" will mean, so that the result cannot be read to suit.
The models. Eight Revit 2024 pairs of VTT's ARCH.zip (the archive Measure already reads for the office; CC BY-SA 4.0; each with Revit 24.0.5's own IFC4 export), none scored by any Measure run so far: Housing Concrete and Timber, each As-Built and BuildingPermit; Housing Terrain-Concrete and Terrain-Timber (permit); Office Timber As-Built and BuildingPermit. The Housing files, six of the eight pairs, are a second design; the Office Timber pair is a structural variant of the office already measured and counts as the same project (a further state, like as built and permit). They are ordinary development reference models (W4, W6, W7), not W5 candidates: tier-2 tests read their .rvt files and RE-178 fixed columns against them.
The measurement. One filtered Measure run per the new models, each model in a shard of its own, every scorer in tools/ci/measure-reference-models.sh's default lists plus the research scorers named in the table (a second dispatch, since a named list replaces the default), on one fixed commit of main (named in the pull request that adds the models and in the report; it does not move between the posting of this and the run), with no rule change in between. Its raw results go into a report (RE-402) whatever they say. A rule that does not hold is a finding, repaired in its own pull request after the first measurement is on the record. A rule is never tuned to these models in the pull request that adds them.
The criterion, for every row. A census line is a Set.Name line of qtos_vs_ifc or psets_vs_ifc: N, equal E, different D, missing M, plus the totals' "values Revit does not write". A rule on a census line holds on a model iff the line reads different 0 and none of its values is among those rvt-rs writes that Revit's export does not; it is exercised by E objects, and E = 0 is not exercised, never "holds". A rule on a body or a structure holds iff the named scorer finds no object the rule changes outside the bar its report states, and is exercised by the number of objects that carry the rule's marker in the model's diagnostics.json (the exported.* counter or BodySource the report names). A rule on a quantity that Revit gives some objects and not others also holds only if none of the objects Revit omits it on gets it. A model's other census lines are read the same way, and any different > 0 or any value rvt-rs writes that Revit omits, on any line, is a finding whether or not a row names it.
Not applicable on Revit 2024: RE-377 (curtain panel material, Revit 2015 to 2023), RE-181 and RE-220 (Revit 2014 and 2015 rows), RE-319 (Revit 2018 conduits). They are not tested here.
Rule (report)
Measured by
Exercised by (read as above)
Curtain panel Width (RE-396)
census Qto_PlateBaseQuantities.Width
its E
Volumes of meshes (RE-387)
census Qto_MemberBaseQuantities.NetVolume, Qto_PlateBaseQuantities.NetVolume, Qto_ColumnBaseQuantities.NetVolume
each E
Mullion NetSurfaceArea from the ends the boxes keep (RE-268; RE-400 if it has landed)
census Qto_MemberBaseQuantities.NetSurfaceArea, mullion_ends_vs_boxes (named, --no-saved-meshes export)
E
Columns cut by a slab and the round column (RE-291, RE-353)
census Qto_ColumnBaseQuantities.{CrossSectionArea,GrossVolume,Length,NetVolume,OuterSurfaceArea}
each E
Wall Height where nothing joins or cuts, and where a roof joins (RE-266, RE-293)
census Qto_WallBaseQuantities.Height
E
Wall volumes and side areas from the saved mesh and the four-vertical-faces gate (RE-270, RE-388); the gate holds only if no wall Revit gives a volume alone gets a side area or a gross volume, which is different 0 and no value Revit omits on NetSideArea, GrossSideArea and GrossVolume
census Qto_WallBaseQuantities.{NetVolume,NetSideArea,GrossSideArea,GrossVolume}
each E
Space NetVolume of a prism room (RE-296)
census Qto_SpaceBaseQuantities.NetVolume
E
Railing Length of a stair-well railing (RE-254)
census Qto_RailingBaseQuantities.Length
E
Door and window Width, Height, Area where the symbol and the type agree (RE-215, RE-373)
census Qto_DoorBaseQuantities.*, Qto_WindowBaseQuantities.*, door_window_sizes_vs_ifc
each E
Opening FireExit from its door (RE-386)
census Pset_OpeningElementCommon.FireExit
E
Openings of a host's own geometry and profile openings carry the host's type name and the profile's area in Reference (RE-381, RE-382)
census Pset_OpeningElementCommon.Reference and the environmental reference keys the report names
E
Sloped floor PitchAngle (RE-384)
census Pset_SlabCommon.PitchAngle
E
Door types' FireRating, family types' Manufacturer, type value blocks (RE-354, RE-373)
the type: keys of psets_vs_ifc, type_objects_vs_ifc
E
Parameters named for a standard property (RE-194; user-defined set values stay out of scope, RE-239)
psets_vs_ifc lines whose property the file's parameters name
E of those lines
Walls a floor covers in part drawn stepped (RE-320)
expected to be not exercised: ARK files are architectural
Rows are added, never removed, when a report turns up a rule that this list missed; a row added after the first run says so. Whether a rule that rests on one project may ship at all remains the owner's call; this measurement is what that call needs.
RE-444 follow-up (W7, #1710, #1046): which type each frame of a wall names, rows registered before the run is read
Question. On the BIM4LCA timber office at building permit the walls 1436343 and 2114950 are named "Basic Wall:VS-2" from their older frame (Partitions/374) in main and name no type from their newest frame (Partitions/424) in #1799 (Measure 43139762399; the walls' Width, Reference, NetVolume and their openings' Depth follow). The type is unique_type_reference (RE-28) over the frame's +0x88 list, which is fail-closed: None unless the list names exactly one distinct type-definition record of the Walls category. So the newest frame's list either names none (a), names two or more (b), or does not decode (c).
The probe is probe_re444_frame_type_slots (branch research/444-type-slots, 7215970c), on nordic-*, Core Interior and RE1 Architecture, no scorer: for each wall framed in several partitions whose frames do not all read the same, each frame's kind (no_list, zero, one=<id>, many=<ids>) and its slots, then the type records those slots name.
Rows (hold iff):
One cause, read. For both walls the newest frame reads as exactly one of (a), (b), (c), and the line shows the slots.
If (a) or (b), the type Revit exports is named in the list. The type Revit's export gives each wall (IfcWallType name) is a type record the newest frame's list names, as a definition or not; if the list holds it as a non-definition record or in a partition the scan does not read, that is the miss.
Counts. Over the BIM4LCA files the walls whose old pick is one type and whose newest frame names none or several (lost_with_newest) are named with their ids; gained_with_newest is named too. Core Interior and RE1 Architecture are framed once and print no wall line.
A rule is written only if Revit agrees. A change that reads the type from the newest frame in more cases is measured on every wall it moves against Revit's export (IfcWallType name and Width); an exporter disagreement is left out (standing rule).
Anything else is a measured negative and is reported as one.
RE-446 (W7, #1802, #1046): the copies of a wall type's compound structure, rows registered before the run is read
Question. On the BIM4LCA timber office at building permit the types VS-2.CLTpinta (3408088) and SPR-1 (2435488) get no layers on main, so their 12 walls (8 and 4) have no IfcWallType, Width or Reference, and the two walls RE-444 retypes (1436343, 2114950, #1799) join the first. The export reads a type's layers from every Partitions/* copy of its data and drops a type whose copies do not give one list (partition_compound_structure::scan_type_layers); the names of the same types already take the latest partition's copy (#807, RE-145). The probe is probe_re446_type_layer_copies (branch research/446-type-layers, fd3c04f9), on nordic-*, Core Interior and RE1 Architecture, no scorer: each wall type's copies (partition, offset, layers) and a verdict, agree, disagree, none (no copy decodes) or single.
Rows (hold iff):
One cause per type. Each of the two types is disagree (its copies give different lists) or none (no copy decodes), and the output shows which; for disagree the copies are listed with their layers.
If disagree, the latest copy is Revit's. The latest copy's total width of VS-2.CLTpinta is 158 mm (Revit's Qto_WallBaseQuantities.Width of walls 1436343 and 2114950 is 0.158 m), and the older copy's is not; for SPR-1 the latest copy's total is the width Revit gives its 4 walls (read from Revit's export in the next step, not here).
Counts. Over the 14 models the wall types with disagree and with none are counted per file; a type that every file reads (agree or single) is untouched. Core Interior and RE1 Architecture have no disagree type that a wall uses, or the ones they have are named.
A rule is written only if Revit agrees. A change that takes the latest copy where the copies disagree is measured on every wall type it moves (layer count, widths, materials) against Revit's IfcMaterialLayerSet, and holdout=true; where Revit's exporters disagree the value is left out (standing rule).
Anything else is a measured negative and is reported as one.
RE-446 (W7, #1802, #1046): the change, rows registered before the run is read
The probe's rows held (comment 6813373825; Measure 43147467736 and, with the routed partition added, 43149619654): of the 14 models it ran, 9 wall types have copies of their layers in two partitions that disagree, and the export drops each of them: on the BIM4LCA timber office at permit VS-2.CLTpinta (3408088, 10 walls: 166 mm in Partitions/374, 158 mm in Partitions/410, Revit's Width 0.158 m) and SPR-1 (2435488, 4 walls: one 150 mm layer, then 25 + 25 + 100 mm); on the concrete housing as built 1393872 (11 walls), 1423048 (22) and 1622382 (1), and at permit 1393872 (6), 1454373 (8), 1458023 (16) and 1573456 (4). In every one the partition the element index routes the type to (current_partitions) is the latest. The change (scan_type_layers, partition_compound_structure.rs): a type whose copies disagree takes the copy of its current partition where the copies in it give one list, and none otherwise.
Measured against #1799's head 985cdb70 (base= that commit, so the run shows RE-446 alone), unfiltered with holdout=true, samples=true and keep_ifc. Rows (hold iff):
The two types get their layers, and Revit's. On the timber office at permit the 14 walls of VS-2.CLTpinta and SPR-1 gain an IfcWallType, a layer set and a Width; the 10 walls' Width is 0.158 m, Revit's, and the 4 SPR-1 walls' is the width Revit writes; Qto_WallBaseQuantities.Width missing falls 14 to 0 or to the walls Revit also leaves out and different stays 0; Pset_WallCommon.Reference missing falls by the same walls and none is different; the 5 openings' Depth that fix(elements): of an element framed in several partitions the exporter keeps the newest frame, not the one with the greatest height (#1710) (RE-444) #1799 leaves missing become Revit's.
The layer sets agree with Revit's.layer_sets_vs_ifc on the five BIM4LCA housing and office files: for the walls that gain a layer set, the layer count, the spans within 0.001 ft and the material set equal Revit's on at least 90% of them, and the rest are named with the copy that was taken; where the older copy was Revit's (a type Revit's export shows with the older layers), the row is a measured negative and the rule is narrowed.
Nothing gets worse. No census row of any of the 42 models with a Revit export gains a different, equal falls on none, rvt-rs values Revit does not write rises on none, the held-out pairs and the same-project gates pass.
What moves. Only exports with a host type (wall, floor, roof, ceiling) whose copies disagree: of the files probed the timber office at permit and the concrete housing as built and at permit (and the floors, roofs and ceilings of any file whose types disagree, named from the element diff); the as-built offices, the concrete office at permit, Core Interior, RE1 and the 24 Revit 2025 models are byte for byte main's unless an element diff says otherwise, and every changed element is one whose type is among those.
The Autodesk samples are read, not gated. Any sample that moves is named with the type whose copy changed.
Anything else is a measured negative and is reported as one.
RE-446: what the first run found, and the rows of the second (registered before the second run is read)
The first run (Measure 43151004964, a09e1f5e against #1799's head 985cdb70) held rows 1, 2, 4 and 5 and all of row 3 but one line: 7 of 126 exports moved, the timber office at permit and the four housing files and the terrain timber housing as the rows predicted (floors, roofs and coverings gained layers as well as walls) and one held-out file, bimspeed-frigento-2020 (Revit 2020). Over the 42 models with a Revit export no census row gained a different (quantities equal 159,508 to 159,866, missing 14,337 to 13,962; properties equal 202,046 to 202,534, missing 11,706 to 11,237; rvt-rs values Revit does not write 17 and 273 unchanged), and on the timber office at permit Qto_WallBaseQuantities.Width is equal on 586 of 586 (572 before), Pset_WallCommon.Reference on 586 of 586, the openings' Depth on 284 of 284, and every layer set written is within 0.001 ft of Revit's (559 of 559). The held-out file's materials row got worse: 5 floors gained layer sets of Revit's widths (layer sets written 12 to 17, all within 0.001 ft), one with Revit's material set and four without (IfcSlab different sets 2 to 6), so a measured negative on Revit 2020.
The change is narrowed to where it is measured: the current copy is taken on Revit 2024 and later (the 64-bit layout, the 1.0 scope of the criteria page), and a type whose copies disagree stays dropped on 2008 to 2023. Second run: unfiltered, holdout=true, samples=true, keep_ifc, against main1d76c82f. Rows (hold iff):
The seven-file move of the first run is six: the same BIM4LCA files and the terrain timber housing, with the same censuses, byte for byte the first run's head for each (the 64-bit path is unchanged).
The held-out file bimspeed-frigento-2020 is byte for byte main's (no layer set written beyond the 12, IfcSlab different sets 2).
No census row of the 42 models gains a different; the same-project gates pass; the Autodesk samples and the other 17 held-out models are byte for byte main's.
RE-446's second run read (Measure 43155545709, head 0047fbf1 against main1d76c82f; PR #1807). The rows of the addendum above:
Held. 126 exports: 120 byte-identical, 6 moved: the first run's seven without the held-out file. Each of the six is byte for byte the first run's, so every scorer file of them is.
Held.bimspeed-frigento-2020 is byte for byte main's.
Held. Over the 42 models with a Revit export quantities equal 159,508 to 159,866 (missing 14,337 to 13,962), properties equal 202,046 to 202,534 (missing 11,706 to 11,237), different 5 and 10 and rvt-rs's own 17 and 273 unchanged; same-project gates pass (15 samples, the Areas on 4 saves and the 2021 save); cmp_measure.py lists 0 census and 0 body-scorer regressions; the Autodesk samples, the other 17 held-out models, Core Interior, RE1 and the 24 Revit 2025 models are byte for byte main's.
Read beyond the rows, and what it costs (all in the report): the quantity census counts 17 fewer (the Length of 17 walls moved from missing to RE-252's walls counted apart, no value written); Pset_<Class>Common.IsExternal is missing on the 19 type objects the change creates (no type has it, #1185); the bodies of 6 walls of the timber office and 6 walls and 16 coverings of the concrete housing at permit change with their layers, and two wall ends of that housing that were exact are 0.27 and 0.29 m off (#1806); Revit 2008 to 2023 stay as they were (#1805); and no model but six BIM4LCA files holds a type the rule reaches.
Rows for the read of #1806 (RE-447), registered before the run: Measure probe_re252_wall_ends and wall_ends_list (which now lists every wall with an end off by more than 0.001 ft, not the 40 largest, branch research/447-wall-ends) on nordic-housing-concrete-permit at 7b577489, the code of #1807, base=none.
The reach. For the walls 1347019 and 1347016 the partition reader's reach fields (m_wall_join_*, RE-70, RE-73) hold a reach or a stop of 0.285 and 0.27 m at the end that moved. If they are empty, the join-reach rule is not the cause and what the line path leaves out is the box path's own JoinTrim (0.285 and 0.27 m).
The whole file. The full list of the walls whose ends are not exact says, for the 71 walls that are not exact on main and the walls that are not exact with the layers, how many ends moved to or from exact and which BodySource and join lists they have: every end that went from exact to off lies at an end with a join list, and no wall with free ends moves.
No claim about Revit's body beyond what the scorer reads from its export; a rule is written only if it is Revit's on every wall of the file and does not move the other five BIM4LCA files.
RE-447 (#1806): rows registered before the run. Change d052a376 on fix/1806-near-axis-walls: wall_centreline_body takes a wall's line as axis-parallel when its ends lie within 1e-6 ft of each other across the axis, where it took a unit-vector component within 1e-9. tapered_wall_solid and layered_wall_profile pick their run by the same test. One unfiltered Measure against main (314eeace), with the Nordic, Revit 2025, held-out and sample models and every scorer. I read it against these rows:
On nordic-housing-concrete-permit, wall 1347019's end and wall 1347016's start are within 0.001 ft of Revit's export again (0.935 and 0.886 ft off on main). Their BodySource returns to partition_element_record_join_trimmed.
No wall end that is within 0.001 ft of Revit's export on main moves out of it, on any model with a Revit export (wall_ends_list, wall_ends_cv_vs_ifc).
The census: no value moves from equal to different or missing, and "different" and "values Revit does not write" are unchanged on every model. same-project gates pass.
Every export that is byte for byte main's is counted, and every export that moves is named, held-out pairs and samples included.
If row 2 or 3 fails, the test is narrowed or the change is withdrawn, and the read says which walls broke it.
RE-447 (#1806): one more row, added after Measure 43264161874 was dispatched and before any of it is read. Rows 1 to 5 above cannot see an end that is off on main and moves further off.
RE-447 (#1806): the first run read, and the rows of the second.Measure 43264161874 (d052a376 against main314eeace, unfiltered, held-out and samples), against the rows above:
Held for the ends, not for BodySource. 1347019's end and 1347016's start are within 0.001 ft again. Their BodySource stays partition_wall_centreline, because the axis-parallel body is centred on the line, not on the box, so the filter keeps it.
Held. No end within 0.001 ft on main moves out. Ends within 0.001 ft: concrete housing at permit 618 to 621, timber housing at permit 590 to 596, office as built 1,111 to 1,112; timber housing as built 603 unchanged.
Held. 115 of 119 exports are byte for byte main's. The four that move are the concrete housing at permit, the timber housing as built and at permit, and the office as built.
Census held; one other scorer did not. 0 census regressions. type_objects_vs_ifc "global_id agrees" fell 1,289 to 1,287 (concrete permit) and 1,417 to 1,416 (timber permit): three window types (one is "Pihla Kiinteä A:IKK-9.11x18"). door_symbol_flipped reads a window's flip from the side of its host wall's line its centre lies on, within 1e-9 ft. A window centred on a drifting line crossed it when the wall was snapped to the axis through its start.
The second version, 0860153e, rows registered before its run. The axis-parallel tests are as on main again. In the angled branch only, where the box does not close and the line's ends lie within 1e-6 ft across an axis, the wall keeps the box's extent along the axis, at the line's own angle. One unfiltered Measure against main314eeace, rows 2 to 6 as above, plus:
Every model's type objects agree with Revit's GlobalIds as often as on main (no window flip moves). The wall ends read as in the first run: the same ends within 0.001 ft and the same four ends further off. BodySource of the drifting walls stays partition_wall_centreline, which row 1 no longer asks about.
Activity
DrunkOnJava commentedon Nov 10, 2026
One more row, from the review of #1629 (RE-388): the "four or fewer vertical faces" gate that decides which walls get
NetSideArea,GrossSideAreaandGrossVolumebeyondNetVolumeis fitted on one project (the BIM4LCA office: none of its 26 volume-only walls is a plain prism). It stands in for a decision inside Revit's own exporter: revit-ifc (tag IFC_v24.1.0, read for facts only) writes the full wall quantity set only for a wall it exports as an extrusion with an axis, and a wall exported as a BRep getsNetVolumealone. A counts-only scorer on the 26 volume-only walls, checking them against the body item classes in Revit's own export, is running (Measure 42862248369). If the classes match, the gate has a reason beyond one project and this row can go; if not, it needs a second model.DrunkOnJava commentedon Nov 10, 2026
Result for the wall-quantity gate row above (Measure 42862248369, a counts-only scorer): the hypothesis that Revit's exporter writes the full wall set only for walls it draws as an extrusion did not hold. On the BIM4LCA office Revit writes
GrossSideArea,NetSideAreaandGrossVolumeon 304 walls drawn as polygonal face sets and 275 drawn as extrusions, andNetVolumealone on 27 face-set walls and 1 extruded one. So the 26 walls that get a volume only are not explained by how Revit draws them, and RE-388's "four or fewer vertical faces" gate stays an empirical proxy resting on one project. The row stays: it needs a second model with Revit's wall quantities, or a reading of what else decides it.DrunkOnJava commentedon Nov 10, 2026
Rows added after reading the three reports the grep matched, and one that landed since the list was written.
Length): not a single-project row. Its third rule is measured on the BIM4LCA office (Revit 2024) and on puzzbobb's R2025 13 to 16 (Revit 2025), two projects (RE-254 section 4).rac_advanced, saves 2015 to 2024, with one external check, an IFC2X3 export of the project's 2020 state (RE-330 section 0). Second model: none, since no Revit IFC4 export of an Area exists (RE-330 section 6).Width(RE-396, landed in feat(ifc): a curtain panel drawn from its saved mesh as a vertical box carries its Width, the longer horizontal side, as Revit's export writes it (#1046) (RE-396) #1637): one project in two states. The office is the only model whose Revit export holds plate base quantities (RE1 Architecture's holds none, RE-242). Second model: none.The "none" rows so far all ask for the same thing: a Revit 2024 or later model with curtain walls and walls whose own IFC4 export holds base quantities (#408).
DrunkOnJava commentedon Nov 10, 2026
Two updates to the first list.
Plate Width (RE-396) landed in feat(ifc): a curtain panel drawn from its saved mesh as a vertical box carries its Width, the longer horizontal side, as Revit's export writes it (#1046) (RE-396) #1637 and its report is on main. The row stays as written: one project in two states (the BIM4LCA office), the one model with curtain panels and Revit's export.
The wall-quantity gate row (RE-388's four-or-fewer-vertical-faces rule) now has its report: RE-399 (docs(re): RE-399 finds nothing in Revit's bodies or the saved graphics that tells the walls and mullions Revit leaves quantities off (#1046) (RE-399) #1646). Revit's own body class and voiding do not tell the 28 volume-only walls (24 at permit) from the full-set walls on the office, and the 24 Revit 2025 models hold no volume-only wall at all (138 of 138 full set), so the gate is still a one-project proxy. What would settle it is a model with Revit's wall quantities that holds walls with five or more vertical faces; none of the models Measure fetches has one. RE-399 also records that the same check on columns reproduces RE-291 from Revit's side, and that no visibility or filter flag marks a mullion's end faces.
DrunkOnJava commentedon Nov 10, 2026
Pre-registration: the BIM4LCA Housing and Office Timber measurement
Posted before any run on these models. Nothing below is tuned to their results: it names, for each shipped rule that the reports say rests on one project, what "holds on the Housing" will mean, so that the result cannot be read to suit.
The models. Eight Revit 2024 pairs of VTT's
ARCH.zip(the archive Measure already reads for the office; CC BY-SA 4.0; each with Revit 24.0.5's own IFC4 export), none scored by any Measure run so far: Housing Concrete and Timber, each As-Built and BuildingPermit; Housing Terrain-Concrete and Terrain-Timber (permit); Office Timber As-Built and BuildingPermit. The Housing files, six of the eight pairs, are a second design; the Office Timber pair is a structural variant of the office already measured and counts as the same project (a further state, like as built and permit). They are ordinary development reference models (W4, W6, W7), not W5 candidates: tier-2 tests read their.rvtfiles and RE-178 fixed columns against them.The measurement. One filtered Measure run per the new models, each model in a shard of its own, every scorer in
tools/ci/measure-reference-models.sh's default lists plus the research scorers named in the table (a second dispatch, since a named list replaces the default), on one fixed commit ofmain(named in the pull request that adds the models and in the report; it does not move between the posting of this and the run), with no rule change in between. Its raw results go into a report (RE-402) whatever they say. A rule that does not hold is a finding, repaired in its own pull request after the first measurement is on the record. A rule is never tuned to these models in the pull request that adds them.The criterion, for every row. A census line is a
Set.Nameline ofqtos_vs_ifcorpsets_vs_ifc:N, equal E, different D, missing M, plus the totals' "values Revit does not write". A rule on a census line holds on a model iff the line readsdifferent 0and none of its values is among those rvt-rs writes that Revit's export does not; it is exercised byEobjects, andE = 0is not exercised, never "holds". A rule on a body or a structure holds iff the named scorer finds no object the rule changes outside the bar its report states, and is exercised by the number of objects that carry the rule's marker in the model'sdiagnostics.json(theexported.*counter orBodySourcethe report names). A rule on a quantity that Revit gives some objects and not others also holds only if none of the objects Revit omits it on gets it. A model's other census lines are read the same way, and anydifferent > 0or any value rvt-rs writes that Revit omits, on any line, is a finding whether or not a row names it.Not applicable on Revit 2024: RE-377 (curtain panel material, Revit 2015 to 2023), RE-181 and RE-220 (Revit 2014 and 2015 rows), RE-319 (Revit 2018 conduits). They are not tested here.
Width(RE-396)Qto_PlateBaseQuantities.WidthEQto_MemberBaseQuantities.NetVolume,Qto_PlateBaseQuantities.NetVolume,Qto_ColumnBaseQuantities.NetVolumeENetSurfaceAreafrom the ends the boxes keep (RE-268; RE-400 if it has landed)Qto_MemberBaseQuantities.NetSurfaceArea,mullion_ends_vs_boxes(named,--no-saved-meshesexport)EQto_ColumnBaseQuantities.{CrossSectionArea,GrossVolume,Length,NetVolume,OuterSurfaceArea}EHeightwhere nothing joins or cuts, and where a roof joins (RE-266, RE-293)Qto_WallBaseQuantities.HeightEdifferent 0and no value Revit omits onNetSideArea,GrossSideAreaandGrossVolumeQto_WallBaseQuantities.{NetVolume,NetSideArea,GrossSideArea,GrossVolume}ENetVolumeof a prism room (RE-296)Qto_SpaceBaseQuantities.NetVolumeELengthof a stair-well railing (RE-254)Qto_RailingBaseQuantities.LengthEWidth,Height,Areawhere the symbol and the type agree (RE-215, RE-373)Qto_DoorBaseQuantities.*,Qto_WindowBaseQuantities.*,door_window_sizes_vs_ifcEFireExitfrom its door (RE-386)Pset_OpeningElementCommon.FireExitEReference(RE-381, RE-382)Pset_OpeningElementCommon.Referenceand the environmental reference keys the report namesEPitchAngle(RE-384)Pset_SlabCommon.PitchAngleEFireRating, family types'Manufacturer, type value blocks (RE-354, RE-373)type:keys ofpsets_vs_ifc,type_objects_vs_ifcEpsets_vs_ifclines whose property the file's parameters nameEof those lineswall_heights_vs_ifc,wall_bodies_vs_ifc,wall_top_cover_vs_ifc(named)BodySourceslab_bodies_vs_ifc(named),wall_heights_vs_ifcwall_bodies_vs_ifc,wall_ends_cv_vs_ifc,wall_ends_listexported.wall_end_sources,wall_base_sources,wall_profile_top_sources,wall_ends_order_dependentopenings_vs_ifc,opening_boxes_vs_ifc,unfilled_openings_vs_ifcexported.wall_profile_cutswall_ends_cv_vs_ifcroof_bodies_vs_ifc,saved_meshes_vs_ifcaggregates_vs_ifcIfcSystemFurnitureElement(RE-352)class_sets_vs_ifcclass_sets_vs_ifcspace_profiles_vs_ifc,room_names_vs_ifc,space_overlaps_vs_ifcexported.resolved_outline_spacesandapproximate_outline_spaces; rooms outside the last phasetagged_spaces_vs_ifc,space_kinds_vs_ifcopenings_vs_ifcdoor_axes_vs_ifc,oriented_boxes_vs_ifcclass_sets_vs_ifccolumn_bodies_vs_ifcstair_bodies_vs_ifcports_vs_ifc,pipe_bodies_vs_ifc,duct_bodies_vs_ifcRows are added, never removed, when a report turns up a rule that this list missed; a row added after the first run says so. Whether a rule that rests on one project may ship at all remains the owner's call; this measurement is what that call needs.
156 remaining items
DrunkOnJava commentedon Nov 12, 2026
RE-444 follow-up (W7, #1710, #1046): which type each frame of a wall names, rows registered before the run is read
Question. On the BIM4LCA timber office at building permit the walls 1436343 and 2114950 are named "Basic Wall:VS-2" from their older frame (
Partitions/374) inmainand name no type from their newest frame (Partitions/424) in #1799 (Measure 43139762399; the walls'Width,Reference,NetVolumeand their openings'Depthfollow). The type isunique_type_reference(RE-28) over the frame's+0x88list, which is fail-closed:Noneunless the list names exactly one distinct type-definition record of the Walls category. So the newest frame's list either names none (a), names two or more (b), or does not decode (c).The probe is
probe_re444_frame_type_slots(branchresearch/444-type-slots,7215970c), onnordic-*, Core Interior and RE1 Architecture, no scorer: for each wall framed in several partitions whose frames do not all read the same, each frame's kind (no_list,zero,one=<id>,many=<ids>) and its slots, then the type records those slots name.Rows (hold iff):
IfcWallTypename) is a type record the newest frame's list names, as a definition or not; if the list holds it as a non-definition record or in a partition the scan does not read, that is the miss.lost_with_newest) are named with their ids;gained_with_newestis named too. Core Interior and RE1 Architecture are framed once and print nowallline.IfcWallTypename andWidth); an exporter disagreement is left out (standing rule).Anything else is a measured negative and is reported as one.
DrunkOnJava commentedon Nov 12, 2026
RE-446 (W7, #1802, #1046): the copies of a wall type's compound structure, rows registered before the run is read
Question. On the BIM4LCA timber office at building permit the types
VS-2.CLTpinta(3408088) andSPR-1(2435488) get no layers onmain, so their 12 walls (8 and 4) have noIfcWallType,WidthorReference, and the two walls RE-444 retypes (1436343, 2114950, #1799) join the first. The export reads a type's layers from everyPartitions/*copy of its data and drops a type whose copies do not give one list (partition_compound_structure::scan_type_layers); the names of the same types already take the latest partition's copy (#807, RE-145). The probe isprobe_re446_type_layer_copies(branchresearch/446-type-layers,fd3c04f9), onnordic-*, Core Interior and RE1 Architecture, no scorer: each wall type's copies (partition, offset, layers) and a verdict,agree,disagree,none(no copy decodes) orsingle.Rows (hold iff):
disagree(its copies give different lists) ornone(no copy decodes), and the output shows which; fordisagreethe copies are listed with their layers.disagree, the latest copy is Revit's. The latest copy's total width ofVS-2.CLTpintais 158 mm (Revit'sQto_WallBaseQuantities.Widthof walls 1436343 and 2114950 is 0.158 m), and the older copy's is not; forSPR-1the latest copy's total is the width Revit gives its 4 walls (read from Revit's export in the next step, not here).disagreeand withnoneare counted per file; a type that every file reads (agreeorsingle) is untouched. Core Interior and RE1 Architecture have nodisagreetype that a wall uses, or the ones they have are named.IfcMaterialLayerSet, and holdout=true; where Revit's exporters disagree the value is left out (standing rule).Anything else is a measured negative and is reported as one.
DrunkOnJava commentedon Nov 12, 2026
RE-446 (W7, #1802, #1046): the change, rows registered before the run is read
The probe's rows held (comment 6813373825; Measure 43147467736 and, with the routed partition added, 43149619654): of the 14 models it ran, 9 wall types have copies of their layers in two partitions that disagree, and the export drops each of them: on the BIM4LCA timber office at permit
VS-2.CLTpinta(3408088, 10 walls: 166 mm inPartitions/374, 158 mm inPartitions/410, Revit'sWidth0.158 m) andSPR-1(2435488, 4 walls: one 150 mm layer, then 25 + 25 + 100 mm); on the concrete housing as built 1393872 (11 walls), 1423048 (22) and 1622382 (1), and at permit 1393872 (6), 1454373 (8), 1458023 (16) and 1573456 (4). In every one the partition the element index routes the type to (current_partitions) is the latest. The change (scan_type_layers,partition_compound_structure.rs): a type whose copies disagree takes the copy of its current partition where the copies in it give one list, and none otherwise.Measured against #1799's head
985cdb70(base=that commit, so the run shows RE-446 alone), unfiltered withholdout=true,samples=trueandkeep_ifc. Rows (hold iff):VS-2.CLTpintaandSPR-1gain anIfcWallType, a layer set and aWidth; the 10 walls'Widthis 0.158 m, Revit's, and the 4SPR-1walls' is the width Revit writes;Qto_WallBaseQuantities.Widthmissing falls 14 to 0 or to the walls Revit also leaves out and different stays 0;Pset_WallCommon.Referencemissing falls by the same walls and none is different; the 5 openings'Depththat fix(elements): of an element framed in several partitions the exporter keeps the newest frame, not the one with the greatest height (#1710) (RE-444) #1799 leaves missing become Revit's.layer_sets_vs_ifcon the five BIM4LCA housing and office files: for the walls that gain a layer set, the layer count, the spans within 0.001 ft and the material set equal Revit's on at least 90% of them, and the rest are named with the copy that was taken; where the older copy was Revit's (a type Revit's export shows with the older layers), the row is a measured negative and the rule is narrowed.different, equal falls on none,rvt-rs values Revit does not writerises on none, the held-out pairs and the same-project gates pass.main's unless an element diff says otherwise, and every changed element is one whose type is among those.Anything else is a measured negative and is reported as one.
fix(elements): of an element framed in several partitions the exporte…
DrunkOnJava commentedon Nov 12, 2026
RE-446: what the first run found, and the rows of the second (registered before the second run is read)
The first run (Measure 43151004964,
a09e1f5eagainst #1799's head985cdb70) held rows 1, 2, 4 and 5 and all of row 3 but one line: 7 of 126 exports moved, the timber office at permit and the four housing files and the terrain timber housing as the rows predicted (floors, roofs and coverings gained layers as well as walls) and one held-out file,bimspeed-frigento-2020(Revit 2020). Over the 42 models with a Revit export no census row gained a different (quantities equal 159,508 to 159,866, missing 14,337 to 13,962; properties equal 202,046 to 202,534, missing 11,706 to 11,237;rvt-rs values Revit does not write17 and 273 unchanged), and on the timber office at permitQto_WallBaseQuantities.Widthis equal on 586 of 586 (572 before),Pset_WallCommon.Referenceon 586 of 586, the openings'Depthon 284 of 284, and every layer set written is within 0.001 ft of Revit's (559 of 559). The held-out file's materials row got worse: 5 floors gained layer sets of Revit's widths (layer sets written 12 to 17, all within 0.001 ft), one with Revit's material set and four without (IfcSlabdifferent sets 2 to 6), so a measured negative on Revit 2020.The change is narrowed to where it is measured: the current copy is taken on Revit 2024 and later (the 64-bit layout, the 1.0 scope of the criteria page), and a type whose copies disagree stays dropped on 2008 to 2023. Second run: unfiltered,
holdout=true,samples=true,keep_ifc, againstmain1d76c82f. Rows (hold iff):headfor each (the 64-bit path is unchanged).bimspeed-frigento-2020is byte for bytemain's (no layer set written beyond the 12,IfcSlabdifferent sets 2).main's.DrunkOnJava commentedon Nov 12, 2026
RE-446's second run read (Measure 43155545709, head
0047fbf1againstmain1d76c82f; PR #1807). The rows of the addendum above:bimspeed-frigento-2020is byte for bytemain's.same-project gatespass (15 samples, the Areas on 4 saves and the 2021 save);cmp_measure.pylists 0 census and 0 body-scorer regressions; the Autodesk samples, the other 17 held-out models, Core Interior, RE1 and the 24 Revit 2025 models are byte for bytemain's.Read beyond the rows, and what it costs (all in the report): the quantity census counts 17 fewer (the
Lengthof 17 walls moved from missing to RE-252's walls counted apart, no value written);Pset_<Class>Common.IsExternalis missing on the 19 type objects the change creates (no type has it, #1185); the bodies of 6 walls of the timber office and 6 walls and 16 coverings of the concrete housing at permit change with their layers, and two wall ends of that housing that were exact are 0.27 and 0.29 m off (#1806); Revit 2008 to 2023 stay as they were (#1805); and no model but six BIM4LCA files holds a type the rule reaches.DrunkOnJava commentedon Nov 12, 2026
Rows for the read of #1806 (RE-447), registered before the run: Measure
probe_re252_wall_endsandwall_ends_list(which now lists every wall with an end off by more than 0.001 ft, not the 40 largest, branchresearch/447-wall-ends) onnordic-housing-concrete-permitat7b577489, the code of #1807,base=none.reachfields (m_wall_join_*, RE-70, RE-73) hold a reach or a stop of 0.285 and 0.27 m at the end that moved. If they are empty, the join-reach rule is not the cause and what the line path leaves out is the box path's ownJoinTrim(0.285 and 0.27 m).mainand the walls that are not exact with the layers, how many ends moved to or from exact and whichBodySourceand join lists they have: every end that went from exact to off lies at an end with a join list, and no wall with free ends moves.fix(elements): a wall, floor, ceiling or roof type edited since an ea…
DrunkOnJava commentedon Nov 12, 2026
RE-447 (#1806): rows registered before the run. Change
d052a376onfix/1806-near-axis-walls:wall_centreline_bodytakes a wall's line as axis-parallel when its ends lie within 1e-6 ft of each other across the axis, where it took a unit-vector component within 1e-9.tapered_wall_solidandlayered_wall_profilepick their run by the same test. One unfiltered Measure againstmain(314eeace), with the Nordic, Revit 2025, held-out and sample models and every scorer. I read it against these rows:nordic-housing-concrete-permit, wall 1347019's end and wall 1347016's start are within 0.001 ft of Revit's export again (0.935 and 0.886 ft off onmain). TheirBodySourcereturns topartition_element_record_join_trimmed.mainmoves out of it, on any model with a Revit export (wall_ends_list,wall_ends_cv_vs_ifc).BodySourceor body changes is listed by model. In the concrete housing at permit, the walls whose line drifts between 1e-9 of its length and 1e-6 ft are 21 by the wall probe of Concrete housing at permit: two wall ends that were exact are 0.27 and 0.29 m off once the walls' types have their layers (1347019, 1347016) #1806's run: the two above, 1346777 and 1426856 (off at their start onmain), and 17 whose ends are within 0.001 ft onmain, which must stay so.same-project gatespass.main's is counted, and every export that moves is named, held-out pairs and samples included.If row 2 or 3 fails, the test is narrowed or the change is withdrawn, and the read says which walls broke it.
DrunkOnJava commentedon Nov 12, 2026
RE-447 (#1806): one more row, added after Measure 43264161874 was dispatched and before any of it is read. Rows 1 to 5 above cannot see an end that is off on
mainand moves further off.mainand further off with the change is listed, by model and wall, with both errors. Expected from the cause (read from the code and Concrete housing at permit: two wall ends that were exact are 0.27 and 0.29 m off once the walls' types have their layers (1347019, 1347016) #1806's exports): wall 1347019's start, 0.443 to 1.378 ft, and wall 1347016's end, 0.394 to 1.280 ft. The change draws these two walls from their record box again, as before fix(elements): a wall, floor, ceiling or roof type edited since an earlier save takes its current partition's layers on Revit 2024 and later (#1802) (RE-446) #1807, and the box is that much shorter there than the location line. The read says whether anything else moves this way.fix(ifc): take the box's extent at the line's own angle for a wall th…
DrunkOnJava commentedon Nov 12, 2026
RE-447 (#1806): the first run read, and the rows of the second. Measure 43264161874 (
d052a376againstmain314eeace, unfiltered, held-out and samples), against the rows above:BodySource. 1347019's end and 1347016's start are within 0.001 ft again. TheirBodySourcestayspartition_wall_centreline, because the axis-parallel body is centred on the line, not on the box, so the filter keeps it.mainmoves out. Ends within 0.001 ft: concrete housing at permit 618 to 621, timber housing at permit 590 to 596, office as built 1,111 to 1,112; timber housing as built 603 unchanged.main's. The four that move are the concrete housing at permit, the timber housing as built and at permit, and the office as built.type_objects_vs_ifc"global_id agrees" fell 1,289 to 1,287 (concrete permit) and 1,417 to 1,416 (timber permit): three window types (one is "Pihla Kiinteä A:IKK-9.11x18").door_symbol_flippedreads a window's flip from the side of its host wall's line its centre lies on, within 1e-9 ft. A window centred on a drifting line crossed it when the wall was snapped to the axis through its start.The second version,
0860153e, rows registered before its run. The axis-parallel tests are as onmainagain. In the angled branch only, where the box does not close and the line's ends lie within 1e-6 ft across an axis, the wall keeps the box's extent along the axis, at the line's own angle. One unfiltered Measure againstmain314eeace, rows 2 to 6 as above, plus:main(no window flip moves). The wall ends read as in the first run: the same ends within 0.001 ft and the same four ends further off.BodySourceof the drifting walls stayspartition_wall_centreline, which row 1 no longer asks about.docs: the rules that rest on one project, and the projects they rest …
docs: the one-project page lists apart the 13 rules measured on anoth…
docs: the one-project page splits the rules wrong on a second buildin…