Skip to content

Railings are written as record boxes, about a thousand times Revit's volume, and now sit inside their stairs #1635

Open

Description

@DrunkOnJava

What

rvt-rs writes a railing as its record box where the railing's saved mesh is not whole (RE-303, #1247). Revit's railing is a thin body, so the box is far too large: in Measure 42688171578 (head a43f517d, 34 models with a box scorer file) the 109 railings written as boxes across 11 models have a median fill (Revit's volume divided by the box's) of 0.001. No other class is near that: sanitary terminals 0.198, building element proxies 0.144, windows 0.119, doors 0.254, furniture 0.062; members, columns and plates are 1.0 (the box is the body).

Since #1626 the railings of a stair are parts of its IfcStair, so the stair's volume as the sum of its parts now carries the boxes: on the BIM4LCA office, 13 stairs go from within 1 percent of Revit's volume to 2 to 127 times it (stair 2598347: 100.9 ft3, 707.6 with the boxes, Revit 101.6; 12 others about 110 to 117 ft3 against 3,600 to 4,100). A viewer shows the same boxes as before, inside the stair that owns them.

Done when

A railing's body is Revit's, or the railing writes no body, where the saved mesh is not whole. Which of the two is the open question: RE-303 section 3 does not say why a railing's saved mesh lacks parts of Revit's body (rails and balusters may be drawn by other elements' graphics).

Measured

  • box_bodies_vs_ifc.txt per class, counted over the Measure run above (gh run download 42688171578 -n measure-head).
  • partition_element_record_bbox is the BodySource of all 5 railings read under two office stairs (2598347, 2859203).

Related

#1247 (boxes), #1624 (stair railings aggregated), RE-303, RE-390.

Activity

  1. DrunkOnJava commented on Nov 10, 2026

    @DrunkOnJava
    OwnerAuthor

    First result of the question the issue leaves open (why a railing's saved mesh is not whole). probe_re397_railing_saved_graphics (Measure 42874785566, the BIM4LCA office as built and at permit, and two R2025 stair models) prints, for each BaseRailing the export writes, what the saved scene holds for it. The office's 41 railings split in two:

    • 22 Railing:KJO-1 (the stair railings, most of them aggregated under their stair since feat(ifc): a railing that belongs to a stair is aggregated under it, as Revit's export aggregates it (#1624) #1626): the saved graphics record exists and is empty. 0 primitives, 0 triangles, no diagnostic (decoded_saved_graphics), in both files. There is no mesh to draw: the file stores no geometry for them, so only a rebuild from the railing's type and path could replace their boxes. Revit's export writes each as 7 to 15 IfcPolygonalFaceSets (two read: 2598353 has 7, 2859214 has 15).
    • 18 Railing:KAI-1 to KAI-6: the saved mesh is partial. KAI-4 1467318 holds 30 primitives and 60 triangles against 6 face sets in Revit's export; every one reports a reachable GBiFlipControl (RE-303), and some add edge is not an isoparametric interval (KAI-2), edge changes its fixed parameter (KAI-5, KAI-6) or unsupported surface HermiteSurf (KAI-6). The two R2025 stair models' railings hold 6 primitives and 12 triangles, also with a flip control.

    So the thousand-fold boxes are two different problems: no stored geometry (22) and geometry Revit stores in a form the reader does not take whole (18). The next probe (probe_re397_railing_graphics_tree, queued) prints the graph of one railing of each type, to see what the flip control gates.

  2. DrunkOnJava commented on Nov 10, 2026

    @DrunkOnJava
    OwnerAuthor

    Measure 42880570119 (probe_re397_railing_instances, branch probe/re397-railing-instances, the office as built) lists every GInstance of the 41 railings' saved graphics and the volume of the symbol each names, read as an element of its own.

    The 240 instances are of two kinds only, all rigid (their matrices are orthonormal, so a symbol's volume is the instance's):

    • 19 visible and unrestricted: flags 557060, visibility 0, m_targets 0. The traversal draws them.
    • 221 hidden in the normal draw and restricted: flags 557092, visibility 1, m_targets 53246. The traversal skips them as hidden, and would refuse them for the restriction if it did not.

    Against Revit's body volume of each railing (the office's IFC export):

    railings visible instances alone visible plus the restricted instances
    KAI-4, 10 railings 0.385 to 0.437 1.0000 to 1.0016
    KAI-5, 2903645 and 2903804 0.541 0.980
    KAI-1, 1485880 (no restricted instance) 1.0002 1.0002
    KAI-3, 2614259 and 2618205 1.195 and 1.198 the same
    KAI-2, 1749890 and 2902063 0.612 the same
    KAI-5, 2598350 0.170 0.170
    KAI-6, 3076853 0 0
    KJO-1, 22 stair railings 0 0.020 to 0.029

    So the 59% of a KAI-4 railing's body that RE-303 found missing is in the instances the traversal skips twice. What the rest need is different: KAI-3's saved mesh is 19.5% over Revit's body (parts Revit does not draw, or counts once), KAI-2, KAI-5 and KAI-6 lose faces to the parametric reader (shared curved edge ..., 105 diagnostics on KAI-6), and the 22 KJO-1 railings hold only restricted instances whose symbols are mostly nested detail-family filters and refused faces. Next: the symbols' own trees (what the flip control sits beside in KAI-4 and in KAI-3).

  3. added
    area:geometry
    area:ifc
    priority:P2
    type:feature
    on Nov 10, 2026
  4. 21 remaining items

  5. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    Where the railings stand on main (8529bb01), counted from saved_meshes_vs_ifc and box_bodies_vs_ifc on every model with a Revit export (Measure 43656305014, base side):

    • Drawn from their saved meshes, every bounding box within 0.01 ft of Revit's body:
      • BIM4LCA housing: 43 and 43 (concrete), 56 and 56 (timber). Their four terrain files: 2 each.
      • The office's two terrain files: 1 each. RE1 Architecture: 1.
      • The Revit 2025 stair models 13 to 16: 2 each.
      • The BIM4LCA office: 39 of 40 as built and at permit, the fortieth within 0.1 ft.
    • Still drawn as their record box (3):
      • Railing:KAI-6 on the office, as built and at permit. Revit's body fills 0.1% of the box.
      • The 2 railings of 17_Rooms_Stairs_Spiral (R2025). Revit's body fills 1.9% of the box.

    So the issue's count of railings written as boxes "about a thousand times Revit's volume" is down to these three on the measured models. What is owed is unchanged for them: Revit's body, or no body where the saved mesh is not whole. Which saved-mesh refusal keeps each one a box is the next thing to read. The office's refusals are counted by kind in diagnostics.json and not by element. A spiral stair's railing follows a helix, which the mesh walk may refuse as a GHermiteSpline profile curve (19 such refusals on the office).

  6. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    The three railings still drawn as their record box all refuse their saved mesh for one reason: SavedMeshRefusal partial: unsupported surface HermiteSurf. That covers the office's Railing:KAI-6 (3076853, also #1191's row 3d railing) and 17_Rooms_Stairs_Spiral's 13680 and 13684, read from the IFCs kept by Measure 43663939560. So what is left here waits on reading HermiteSurf faces, which draft #1941 does. Once it lands, these three either come from their meshes, each scored against Revit's body, or stay with the reason that then applies.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:geometryarea:ifcpriority:P2type:feature

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions