You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Score Revit 2015 to 2020 angled walls wall by wall, and restore their line bodies if none is worse than its box #1535
area:elementsWork in the elements area.priority:P2Important quality, usability, or hardening work.type:researchReverse engineering, discovery, or design investigation.
#1517 (RE-364) draws Revit 2015 to 2023 walls at an angle along their lines. Its first version, on Vitoria ALD26 Before (Revit 2018), took angled walls' faces from 1 to 33 of 48 within 0.001 ft of Revit's export. The version that lands keeps angled walls on 2015 to 2020 as their boxes unless the box closes on the line's rectangle, because nothing read on those releases marks a slanted wall, which would be drawn as a thin upright slab. So that gain is not kept.
The evidence so far is totals: within 1 ft of Revit's, 13 of 48 on main against 33 of 48 on the first version, and the largest face error 9.67 ft against 9.53 ft. No wall-by-wall comparison exists, and no tested file is known to hold a slanted wall on those releases.
The first version's code is kept at refs/archive/2026-11-08/pr1517-first-head (0aad0b0c).
The same version also wrote wall quantities on 2015 to 2023, which the landed version leaves out. What disagreed with them were Warmond's export, which went through another tool, and an IFC2X3 view, both counted apart; modelo_bim (IFC4) had 1 of 4 equal and 0 different.
Frigento and Vitoria's ALD26 Project stay held out for this issue. Versions are designed and compared on the spent ALD26 Before and Autodesk's samples, and the two held-out projects run once on the final candidate, as totals, for pass or fail. Both projects have already been scored for this work, by Measure runs 42532162952 (the first version) and 42532798082 (the faces-from-line trial), and their totals are in the comments below, so that last run is a pass or fail on files no longer unseen for this rule. It isn't a first measurement or a held-out result in the W5 sense, and no further rule is chosen from them.
Done when
The first version is scored wall by wall, as counts, bodies and Qto_WallBaseQuantities alike, against its box on the 2015 to 2020 models with a Revit export that are not held out.
If no wall is worse than its box, the line bodies return with their own BodySource and the risk stated, in a pull request held to Measure.
If any wall is worse, those walls set how tight the check must be, and RE-364 says so.
The quantities return wherever no untouched IFC4 export disagrees.
First result, Measure run 42532162952: the first version of #1517 (0aad0b0c) against the code before it (ab5f8e1c), on Revit 2015 to 2020 models with a Revit export. Counts only. The scored exports' provenance is in the table.
Angled walls with both faces within 0.001 ft of Revit's:
model
export
angled walls
before
first version
Frigento (2020)
IFC4, untouched
83
0
69
Vitoria project (2018)
IFC2X3
74
1
33
Vitoria ALD26 Before (2018)
IFC2X3
48
1
33
BIMcollab's example (2015)
IFC2X3, rewritten
1
0
1
Wall by wall on ALD26 Before, the one model whose walls can be listed (a difference under 0.001 ft counts as the same):
of 48 angled walls
better
same
worse
faces (across)
32
16
0
ends (along)
17
16
15 (by at most 0.64 ft)
the larger of the two
24
15
9
So no wall's faces get worse, which is what a leaning wall drawn as a thin slab would show; the 15 walls whose faces are more than 1 ft off are off by the same amount before and after. The ends are the real cost: 15 walls end further from Revit's than their box does, since a record on these releases is read without its control joins.
By this issue's done-when, those 15 walls set how tight the check must be. The shape that follows is a body whose faces come from the line and whose ends stay where the record box cuts them, measured on the same models.
Second result: the trial on branch research/1535-faces-from-line (7180ba95), where on 2015 to 2020 an angled wall takes its faces from its line and its ends from its box, with no join reach. Measure run 42532798082 against main at 1e2d3de4.
Faces keep the whole gain, and axis-parallel walls don't move. Ends improve against the first version:
Frigento 2020 (IFC4, untouched, 83 walls)
Vitoria project (IFC2X3, 74)
faces within 0.001 ft
2 to 69
1 to 33
ends within 0.1 ft
2 to 16
8 to 9
ends within 1 ft
28 to 71
74 to 74
Wall by wall on ALD26 Before (48 angled walls), comparing each wall's larger error, faces or ends, against its box:
better
same
worse
first version
24
15
9 (by up to 0.64 ft)
this trial
25
15
8 (by up to 0.11 ft)
Seven of the 8 end 0.277 to 0.279 ft from Revit's, against 0.164 to 0.206 ft for the box; the eighth moves by 0.002 ft. Faces are worse on none, and every wall whose faces are more than 1 ft off is off by the same amount as before.
That near-constant 0.279 ft looks like one cause rather than seven, so it's the next thing to read. By the done-when, the check isn't met yet: 8 walls are still worse than their box, and Frigento's worst end error is up from 2.42 to 3.19 ft.
Third result, from the wall-by-wall rows of run 42532798082 on ALD26 Before: the near-constant 0.279 ft is not yet one explained cause.
All 8 walls the trial leaves worse than their box are the same 10 cm wall type, and their faces are exact (0.000 ft, against up to 0.206 ft for the box). What is worse is the ends only. But the type doesn't separate them from the rest:
thickness
better
same
worse
10 cm (29 walls)
21
0
8
8 cm (19 walls)
4
15
0
So a check on thickness would be a fit to this one model, and it won't be added. The next step is to print what rvt-rs itself reads for each of these walls (how far the box is from the line's rectangle, per axis), to see whether anything available at export time tells the 8 from the 21. If nothing does, this falls under the second case of the done-when: these walls set the limit, RE-364 says so, and the ends wait for the control joins on these releases.
Fourth result, a negative one: run 42541485876, on ALD26 Before only.
Printing what each wall reads showed that all 8 walls the trial leaves worse lie within 5° of a model axis, where one of the trial's two run estimates divides by a component near zero. So I tried taking the run only from the axis the wall mostly lies along (8afa813b).
It doesn't explain them. The 8 walls are worse by exactly the same amounts as before (up to 0.114 ft), so their ends don't depend on that estimate. The counts are 25 better, 15 same and 8 worse, as before, and ends within 0.1 ft go from 8 to 7, so the change is not an improvement. Near-axis walls also appear among the better ones, so being close to an axis doesn't separate them either.
That rules out thickness and this estimate. The trial stays where it was against the done-when: 8 walls are still worse than their box.
Fifth result, from the rows already in runs 42532162952 (the first version) and 42532798082 (the faces-from-line trial), on ALD26 Before.
The 8 walls end exactly as far from Revit's ends under the first version as under the trial: 0.277 to 0.279 ft on 7, and 0.003 ft on the eighth. Those two draw the run differently (the line's own length about its midpoint, and the run the box allows about the box's centre), so the error doesn't come from how the run is estimated. These walls end about 0.28 ft from where their line puts them, and their record box puts them about half a wall thickness (0.164 ft) from Revit's.
What the reader holds for them: none has a join reach (none of the 48 angled walls does on these releases), and on 7 of the 8 the box's two run estimates differ by about one wall thickness, so the box does not close on the line's rectangle. That is also true of one wall the trial improves (706912), so it doesn't separate them.
So, by the done-when's second case, these walls set the limit: a 2015 to 2020 angled wall whose box doesn't close stays its box, as on main. The ends of such walls are a join effect these releases' records don't yet give us. What would settle it is the signed difference at each end (whether Revit's end is past the line's or short of it), which wall_bodies_vs_ifc.py doesn't print. That is the next step here.
Sixth result: the signed difference at each end, which settles the question the fifth one left. Measure run 42558474888 scored the faces-from-line trial (7180ba95) against the code before it (1e2d3de4) on ALD26 Before, with a scorer that lists each end's signed difference from Revit's: positive where rvt-rs's body runs past Revit's end, negative where it stops short (branch measure/1535-ends, 963bb49c, temporary).
The 8 walls the trial leaves worse than their box:
wall
box: start, end (ft)
line: start, end (ft)
705842
+0.164, +0.164
+0.278, +0.277
706031
+0.163, +0.165
+0.279, +0.276
706347
+0.174, +0.014
+0.279, -0.002
706416
+0.174, +0.009
+0.277, -0.004
706468
+0.169, +0.171
+0.275, +0.278
706632
+0.186, +0.186
+0.279, +0.279
706787
+0.184, +0.184
+0.278, +0.279
706109
+0.000, -0.000
-0.003, -0.001
So on 7 of the 8, Revit's wall stops 0.275 to 0.279 ft (about 85 mm) short of the line's end, at both ends or at one, and short of the box's end too. Neither body is Revit's: the line is too long by more than the box is. The eighth, 706109, is within 0.003 ft either way.
That fits a trim at a join, which none of these walls has a reach for on these releases. It fits a rule for their one wall type just as well. All 8 are LKS_T9 10cm, and the 58 ends of that type's 29 angled walls under the line body fall on a few values: 12 are about 0.28 ft past Revit's, 12 about 0.17 ft past, 4 about 0.39 ft short, 4 0.037 ft short, and 26 within 0.02 ft. No step compared Revit's end with a neighbouring wall's face, so neither reading is tested. (Edited: this paragraph first said the 0.28 ft is what a join trim does, which this run does not show.)
Of the 25 walls the trial improves, the faces are what improves. Only 5 have both ends within 0.01 ft of Revit's. The other 20 have 28 ends beyond 0.01 ft: 16 of them are about 0.17 or 0.39 ft, and the rest are between 0.02 and 0.28 ft.
By the done-when's second case, these walls set the limit: on 2015 to 2020, an angled wall whose box does not close on its line's rectangle stays its box, as on main. Which rule gives its ends is not known; the decision holds either way. Next: RE-364 gets an addendum with these tables. The quantities in the done-when's last item stay to be done, separately.
Seventh result, on the done-when's last item (the quantities): the flags that allow them read on 2015 to 2023 exactly as on 2024. RE-364 turned them off for the wrong reason.
A wall's Height needs its record's uncut flag, and its side areas and volumes need whole as well (RE-266, RE-270). Both flags come from the *Step classes in the wall's native record. RE-364 turned them off on 2015 to 2023 because the record's control joins (joins, side_joins, exposed) read empty there. That is a different part of the graph, and nobody had checked the steps.
Measure run 42562621272 ran a new probe, probe_1535_wall_steps (29a382b9), on Autodesk's sample projects of every year. It lists each wall record's step classes and both flags. Each 2015 to 2023 save was then compared wall by wall with the same project's 2024 save (rac_basic with its 2023 save, as RE-364 does):
project
saves
walls each
steps the same
flags the same
rac_advanced
2015 to 2023
180
all
all
rac_basic
2015 to 2022 vs 2023, 2023 vs 2024
60
all but 2 walls of 2015
all
rme_advanced, rme_basic
2015, 2019
166
all
all
rst_basic
2016 to 2023
9
all
all
That is 2,894 of 2,896 walls with the same step classes and all 2,896 with the same uncut and whole. The two walls that differ are rac_basic 2015's. One has one JoinEndGStep where 2023 has two plus a WallEmbedWallGStep, and the other has three JoinEndGSteps where 2023 has two. Neither changes a flag. The four walls of rst_basic 2015 are not in its 2024 save, and rst_advanced has no later save.
So I've opened a change that keeps the flags on 2015 to 2023 (748eff38) and leaves Length out, since Length does depend on the control joins. It is in Measure run 42564158277, against main, on the reference models, the BIM4LCA office, R2025, the samples of every year, racadv and BIMcollab. Next, I check the quantities it writes on each old save against the same wall's quantities in the later save. RE-364 section 5 listed 3 Heights and 19 side areas where the later save writes none, and wall 418079's GrossVolume; each needs a cause before the change goes further. Frigento and ALD26 Project run once, on the final candidate, as totals.
Closing this as answered: both items of the done-when have their measurements, and what is left has an issue of its own.
Angled walls on 2015 to 2020 were scored wall by wall on the spent ALD26 Before, with the signed difference at each end. Eight of the 48 are worse with a line body than with their box at their ends, seven of them 0.275 to 0.279 ft past Revit's end. Those walls set the limit, so an angled wall whose box does not close on its line's rectangle stays its box (RE-364 section 8, docs(re): RE-364 says why Revit 2015 to 2020 angled walls keep their box (#1535) #1567).
area:elementsWork in the elements area.priority:P2Important quality, usability, or hardening work.type:researchReverse engineering, discovery, or design investigation.
Activity
DrunkOnJava commentedon Nov 8, 2026
First result, Measure run 42532162952: the first version of #1517 (
0aad0b0c) against the code before it (ab5f8e1c), on Revit 2015 to 2020 models with a Revit export. Counts only. The scored exports' provenance is in the table.Angled walls with both faces within 0.001 ft of Revit's:
ALD26 Before(2018)Wall by wall on
ALD26 Before, the one model whose walls can be listed (a difference under 0.001 ft counts as the same):So no wall's faces get worse, which is what a leaning wall drawn as a thin slab would show; the 15 walls whose faces are more than 1 ft off are off by the same amount before and after. The ends are the real cost: 15 walls end further from Revit's than their box does, since a record on these releases is read without its control joins.
By this issue's done-when, those 15 walls set how tight the check must be. The shape that follows is a body whose faces come from the line and whose ends stay where the record box cuts them, measured on the same models.
DrunkOnJava commentedon Nov 8, 2026
Second result: the trial on branch
research/1535-faces-from-line(7180ba95), where on 2015 to 2020 an angled wall takes its faces from its line and its ends from its box, with no join reach. Measure run 42532798082 againstmainat1e2d3de4.Faces keep the whole gain, and axis-parallel walls don't move. Ends improve against the first version:
Wall by wall on
ALD26 Before(48 angled walls), comparing each wall's larger error, faces or ends, against its box:Seven of the 8 end 0.277 to 0.279 ft from Revit's, against 0.164 to 0.206 ft for the box; the eighth moves by 0.002 ft. Faces are worse on none, and every wall whose faces are more than 1 ft off is off by the same amount as before.
That near-constant 0.279 ft looks like one cause rather than seven, so it's the next thing to read. By the done-when, the check isn't met yet: 8 walls are still worse than their box, and Frigento's worst end error is up from 2.42 to 3.19 ft.
DrunkOnJava commentedon Nov 9, 2026
Third result, from the wall-by-wall rows of run 42532798082 on
ALD26 Before: the near-constant 0.279 ft is not yet one explained cause.All 8 walls the trial leaves worse than their box are the same 10 cm wall type, and their faces are exact (0.000 ft, against up to 0.206 ft for the box). What is worse is the ends only. But the type doesn't separate them from the rest:
So a check on thickness would be a fit to this one model, and it won't be added. The next step is to print what rvt-rs itself reads for each of these walls (how far the box is from the line's rectangle, per axis), to see whether anything available at export time tells the 8 from the 21. If nothing does, this falls under the second case of the done-when: these walls set the limit, RE-364 says so, and the ends wait for the control joins on these releases.
DrunkOnJava commentedon Nov 9, 2026
Fourth result, a negative one: run 42541485876, on
ALD26 Beforeonly.Printing what each wall reads showed that all 8 walls the trial leaves worse lie within 5° of a model axis, where one of the trial's two run estimates divides by a component near zero. So I tried taking the run only from the axis the wall mostly lies along (
8afa813b).It doesn't explain them. The 8 walls are worse by exactly the same amounts as before (up to 0.114 ft), so their ends don't depend on that estimate. The counts are 25 better, 15 same and 8 worse, as before, and ends within 0.1 ft go from 8 to 7, so the change is not an improvement. Near-axis walls also appear among the better ones, so being close to an axis doesn't separate them either.
That rules out thickness and this estimate. The trial stays where it was against the done-when: 8 walls are still worse than their box.
DrunkOnJava commentedon Nov 9, 2026
Fifth result, from the rows already in runs 42532162952 (the first version) and 42532798082 (the faces-from-line trial), on
ALD26 Before.The 8 walls end exactly as far from Revit's ends under the first version as under the trial: 0.277 to 0.279 ft on 7, and 0.003 ft on the eighth. Those two draw the run differently (the line's own length about its midpoint, and the run the box allows about the box's centre), so the error doesn't come from how the run is estimated. These walls end about 0.28 ft from where their line puts them, and their record box puts them about half a wall thickness (0.164 ft) from Revit's.
What the reader holds for them: none has a join reach (none of the 48 angled walls does on these releases), and on 7 of the 8 the box's two run estimates differ by about one wall thickness, so the box does not close on the line's rectangle. That is also true of one wall the trial improves (706912), so it doesn't separate them.
So, by the done-when's second case, these walls set the limit: a 2015 to 2020 angled wall whose box doesn't close stays its box, as on
main. The ends of such walls are a join effect these releases' records don't yet give us. What would settle it is the signed difference at each end (whether Revit's end is past the line's or short of it), whichwall_bodies_vs_ifc.pydoesn't print. That is the next step here.DrunkOnJava commentedon Nov 9, 2026
Sixth result: the signed difference at each end, which settles the question the fifth one left. Measure run 42558474888 scored the faces-from-line trial (
7180ba95) against the code before it (1e2d3de4) onALD26 Before, with a scorer that lists each end's signed difference from Revit's: positive where rvt-rs's body runs past Revit's end, negative where it stops short (branchmeasure/1535-ends,963bb49c, temporary).The 8 walls the trial leaves worse than their box:
So on 7 of the 8, Revit's wall stops 0.275 to 0.279 ft (about 85 mm) short of the line's end, at both ends or at one, and short of the box's end too. Neither body is Revit's: the line is too long by more than the box is. The eighth, 706109, is within 0.003 ft either way.
That fits a trim at a join, which none of these walls has a reach for on these releases. It fits a rule for their one wall type just as well. All 8 are
LKS_T9 10cm, and the 58 ends of that type's 29 angled walls under the line body fall on a few values: 12 are about 0.28 ft past Revit's, 12 about 0.17 ft past, 4 about 0.39 ft short, 4 0.037 ft short, and 26 within 0.02 ft. No step compared Revit's end with a neighbouring wall's face, so neither reading is tested. (Edited: this paragraph first said the 0.28 ft is what a join trim does, which this run does not show.)Of the 25 walls the trial improves, the faces are what improves. Only 5 have both ends within 0.01 ft of Revit's. The other 20 have 28 ends beyond 0.01 ft: 16 of them are about 0.17 or 0.39 ft, and the rest are between 0.02 and 0.28 ft.
By the done-when's second case, these walls set the limit: on 2015 to 2020, an angled wall whose box does not close on its line's rectangle stays its box, as on
main. Which rule gives its ends is not known; the decision holds either way. Next: RE-364 gets an addendum with these tables. The quantities in the done-when's last item stay to be done, separately.docs(re): RE-364 says the 0.28 ft fits a join trim or a per-type rule…
docs(re): RE-364 counts the improved walls' remaining end errors exac…
docs(re): RE-364 says why Revit 2015 to 2020 angled walls keep their …
DrunkOnJava commentedon Nov 9, 2026
Seventh result, on the done-when's last item (the quantities): the flags that allow them read on 2015 to 2023 exactly as on 2024. RE-364 turned them off for the wrong reason.
A wall's
Heightneeds its record'suncutflag, and its side areas and volumes needwholeas well (RE-266, RE-270). Both flags come from the*Stepclasses in the wall's native record. RE-364 turned them off on 2015 to 2023 because the record's control joins (joins,side_joins,exposed) read empty there. That is a different part of the graph, and nobody had checked the steps.Measure run 42562621272 ran a new probe,
probe_1535_wall_steps(29a382b9), on Autodesk's sample projects of every year. It lists each wall record's step classes and both flags. Each 2015 to 2023 save was then compared wall by wall with the same project's 2024 save (rac_basicwith its 2023 save, as RE-364 does):rac_advancedrac_basicrme_advanced,rme_basicrst_basicThat is 2,894 of 2,896 walls with the same step classes and all 2,896 with the same
uncutandwhole. The two walls that differ arerac_basic2015's. One has oneJoinEndGStepwhere 2023 has two plus aWallEmbedWallGStep, and the other has threeJoinEndGSteps where 2023 has two. Neither changes a flag. The four walls ofrst_basic2015 are not in its 2024 save, andrst_advancedhas no later save.So I've opened a change that keeps the flags on 2015 to 2023 (
748eff38) and leavesLengthout, sinceLengthdoes depend on the control joins. It is in Measure run 42564158277, againstmain, on the reference models, the BIM4LCA office, R2025, the samples of every year,racadvand BIMcollab. Next, I check the quantities it writes on each old save against the same wall's quantities in the later save. RE-364 section 5 listed 3Heights and 19 side areas where the later save writes none, and wall 418079'sGrossVolume; each needs a cause before the change goes further. Frigento andALD26 Projectrun once, on the final candidate, as totals.research(elements): a probe lists each wall record's steps on every r…
2 remaining items
chore(release): prepare v0.16.1 (#1571)
research(re): the quantity scorer counts the values on a Tag Revit's …
research(re): a wall's quantities held to the same project's later sa…
docs(re): RE-364 section 9, a wall's Height on Revit 2015 to 2023 hel…
docs(re): the format notes' RE-364 addendum for a wall record's steps…
docs(re): the addendum counts values, walls and saves apart (#1535)
fix(ifc): Revit 2015 to 2023 walls write their Height where their rec…
DrunkOnJava commentedon Nov 9, 2026
Closing this as answered: both items of the done-when have their measurements, and what is left has an issue of its own.
ALD26 Before, with the signed difference at each end. Eight of the 48 are worse with a line body than with their box at their ends, seven of them 0.275 to 0.279 ft past Revit's end. Those walls set the limit, so an angled wall whose box does not close on its line's rectangle stays its box (RE-364 section 8, docs(re): RE-364 says why Revit 2015 to 2020 angled walls keep their box (#1535) #1567).Height(fix(ifc): Revit 2015 to 2023 walls write their Height where their record names nothing joined to or cutting them; their areas and volumes stay out (#1535) (RE-364) #1578, RE-364 section 9). A wall'suncutandwholeflags come from the*Stepclasses of its native record, which read on Autodesk's 2015 to 2023 samples as on the same projects' 2024 saves (2,896 of 2,896 walls). Held to the 2024 saves wall by wall, 781Heights are equal and none differs. Against Revit's exports, the one untouched IFC4 export that scores them has 1 equal and none different, and on the held-out Revit 2021 project (counts only) every differentHeightsits on a Tag Revit's export gives to several objects, a wall it splits at its storeys; the scorers count those apart now (measure: W7 scores a Tag Revit's export repeats against one of its objects, so a split wall reads as different #1576, research(re): the W7 scorers count apart the values on a Tag Revit's export gives more than one object (#1576) #1581). The side areas, footprint and volumes stay out: on 25 walls the 2024 save draws the wall from its centreline and the old record's box does not match it.Length, the areas and volumes, the angled walls' ends) is Revit 2015 to 2023 walls: the control joins are read (RE-364 section 11) and Length is written for curtain walls and where a wall's curve is not cut back (section 12); side areas, footprint, volumes and angled walls' line bodies stay out #1584.docs(re): save_pair_wall_quantities.py says it names walls by Tag, so…
research(re): the quantity scorer counts the values on a Tag Revit's …
docs: 0.17.0 is the published release, each channel checked from what…
fix(re): save_pair_wall_quantities converts a wall's GrossVolume by t…