From #1509 (RE-362), probe run 42139236978. BIMcollab's Revit 2015 structural example holds 91 structural-framing elements, Revit's export holds 91 beams, and rvt-rs draws all 91 as record boxes, with Span and Slope missing on all 91.
Every beam has a record box and element data, and no copy holds a bounded line record (04 00 08 01) in the window the reader scans, so all 91 fail at no_line, none at the box tests. On Autodesk's 2015 samples the same record is there for most beams that aren't column cuts (33 of 34, 29 of 39, 54 of 64).
Either this file keeps a beam's location line in a record or form that isn't decoded, or the reader's window or tag doesn't reach it. An untried candidate is the native FamInstCurveDriver record, which the beam rotation already reads on 2015 (RE-280); walls take a curve from their native record (#1475).
The export has no licence: counts only.
Done when: where these 91 beams keep their location line is read from the bytes and they're drawn by it, scored against Revit's export of the file on the world box and on Span and Slope; or a measured negative says what was tested.
A measured negative for this issue, from reading the file's bytes locally with the pinned tools/ci/fetch-bimcollab.sh. Counts only; nothing from the file is committed.
There is no location line to find. None of the 91 structural-framing records holds a FamInstCurveDriver or a GLine, so the untried native candidate is ruled out too. Each native record is 8 objects, where the curve-driven beams on rst_basic 2015 have 18 to 43. Each is a family instance placed by InstanceInfo.m_Trf, and each names a FamilySymbol (45 between them) that holds its geometry.
The bodies don't depend on a line. Against Revit's export:
of 91
world box within 3 mm (offset 0.0 m on all)
91
volume within 0.1%
74
The 17 whose volume differs are all the steel-section types, so this looks like the I-section gap (RE-103, not tried on these releases), not a location. I didn't score their profiles.
Span isn't a line's length here. Revit's Pset_BeamCommon.Span equals BaseQuantities.Length on all 91, and Slope is 0 on all 91. Span equals one extent of the symbol's FamilySymbol.m_outline on all 91: its Y extent on 43 and its X extent on 48. On those 48 it is shorter than the beam's long world extent, by up to about 15 m. So Revit's value looks like the depth of the extrusion it exported, though I didn't read that from revit-ifc.
What this leaves:
I have no rule for what chooses between X and Y, so no Span to propose. I only looked at the outline and the object counts (450 faces and 450 planes across the 45 symbols); the faces themselves aren't compared, and that's where I'd look next.
Taking the long extent would match 43 of 91. Taking one fixed axis would match 43 or 48. Fitting a choice to this one file, with no other point-placed beam to check it on, would not be a measurement.
Slope could be written as 0 from m_Trf, whose Z axis is up on all 91, but that is also one file.
So I'd close this as a measured negative and leave these beams as they are: their boxes are Revit's. The 17 steel sections stay as they are too: the I-section parameter (-1005502) has no hit in this file, as on Autodesk's samples of 2015 and 2016, where a section's values sit under ids of the document's own (RE-365).
A related note on Autodesk's samples: the 10 beams on rst_basic 2015 that read no line and aren't column cuts do have a native GLine, and the ones I looked at are vertical (m_dirVec 0, 0, 1). That is a different case from this file, and I didn't look at the 11 on rac_advanced and rst_advanced.
The local probes behind these counts aren't committed. I can add one in the restricted output tools/ci/scrub-holdout-results.sh keeps, if you want Measure to reproduce them.
@puzzbobb thanks, that meets this issue's done-when: a measured negative that says what was tested, with the boxes Revit's on all 91. Closing it on that basis.
Yes please to the probe in the restricted output. It would let Measure repeat these counts, which for now rest on your local run. I'll add your result to RE-362 as your local counts when #1509 lands, so it's in the report as well as here. Span stays unwritten on these beams: nothing yet says whether X or Y is the extent to take, and as you say, a rule fitted to one file wouldn't be a measurement.
area:elementsWork in the elements area.priority:P3Useful follow-up work after core milestones land.type:researchReverse engineering, discovery, or design investigation.
Activity
puzzbobb commentedon Nov 6, 2026
A measured negative for this issue, from reading the file's bytes locally with the pinned
tools/ci/fetch-bimcollab.sh. Counts only; nothing from the file is committed.There is no location line to find. None of the 91 structural-framing records holds a
FamInstCurveDriveror aGLine, so the untried native candidate is ruled out too. Each native record is 8 objects, where the curve-driven beams onrst_basic2015 have 18 to 43. Each is a family instance placed byInstanceInfo.m_Trf, and each names aFamilySymbol(45 between them) that holds its geometry.The bodies don't depend on a line. Against Revit's export:
The 17 whose volume differs are all the steel-section types, so this looks like the I-section gap (RE-103, not tried on these releases), not a location. I didn't score their profiles.
Spanisn't a line's length here. Revit'sPset_BeamCommon.SpanequalsBaseQuantities.Lengthon all 91, andSlopeis 0 on all 91.Spanequals one extent of the symbol'sFamilySymbol.m_outlineon all 91: its Y extent on 43 and its X extent on 48. On those 48 it is shorter than the beam's long world extent, by up to about 15 m. So Revit's value looks like the depth of the extrusion it exported, though I didn't read that from revit-ifc.What this leaves:
Spanto propose. I only looked at the outline and the object counts (450 faces and 450 planes across the 45 symbols); the faces themselves aren't compared, and that's where I'd look next.Slopecould be written as 0 fromm_Trf, whose Z axis is up on all 91, but that is also one file.So I'd close this as a measured negative and leave these beams as they are: their boxes are Revit's. The 17 steel sections stay as they are too: the I-section parameter (
-1005502) has no hit in this file, as on Autodesk's samples of 2015 and 2016, where a section's values sit under ids of the document's own (RE-365).A related note on Autodesk's samples: the 10 beams on
rst_basic2015 that read no line and aren't column cuts do have a nativeGLine, and the ones I looked at are vertical (m_dirVec0, 0, 1). That is a different case from this file, and I didn't look at the 11 onrac_advancedandrst_advanced.The local probes behind these counts aren't committed. I can add one in the restricted output
tools/ci/scrub-holdout-results.shkeeps, if you want Measure to reproduce them.DrunkOnJava commentedon Nov 8, 2026
@puzzbobb thanks, that meets this issue's done-when: a measured negative that says what was tested, with the boxes Revit's on all 91. Closing it on that basis.
Yes please to the probe in the restricted output. It would let Measure repeat these counts, which for now rest on your local run. I'll add your result to RE-362 as your local counts when #1509 lands, so it's in the report as well as here.
Spanstays unwritten on these beams: nothing yet says whether X or Y is the extent to take, and as you say, a rule fitted to one file wouldn't be a measurement.docs(re): RE-362 gives the final run and BIMcollab's measured negative (
feat(ifc): Revit 2015 to 2023 beams are drawn along their location li…
chore(release): prepare v0.16.0 (#1564)
feat(ifc): Revit 2017 to 2023 steel beams are drawn as their type's I…