You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
RE1 Plumbing: water closet tank 442378 is written, and Revit's export holds neither it nor its type #1496
Known since B38 (docs/archive/BACKLOG.md), RE-160, RE-169 section 4 and RE-262, with no open issue until now. On RE1 Plumbing, rvt-rs writes water closet tank 442378 and its type 442362 (224200-FIXT-Rough In Water Closet Tank:Water Closet Tank_M, as IfcSanitaryTerminalType), and Revit's own export holds neither. tests/element_records_2025.rs pins it.
Every property on that type is therefore a value Revit does not write: Pset_EnvironmentalImpactIndicators.Reference, Pset_SanitaryTerminalTypeCommon.Reference, and now Pset_ManufacturerTypeInformation.Manufacturer (#1490, RE-354). No property-level rule can fix that; the element shouldn't be written. RE1's export is IFC2X3, counted apart, and a held-out or IFC4 export may say otherwise.
Done when: what separates this tank from the fixtures Revit does export is read from the bytes, and the rule leaves it out with 0 false negatives on every model with an export; or a measured negative says what was tested, and it stays written, counted.
Activity
research(elements): RE-363 probe looks the category up by value, not …
docs: #1185 is closed by RE-354, and its residuals are #1507, #1496 and
research(elements): RE-363 reads every family instance's saved body f…
research(elements): RE-363 times the saved-graphics pass against the …
research(elements): RE-363 times a pass over only the plumbing fixtur…
research(elements): what separates the water closet tank Revit's expo…
research(elements): RE-363 probe at the level of a fixture's type, an…
research(elements): RE-363 reports what separates the tank Revit's ex…
research(elements): RE-363's rule table reads as measured (#1496)
research(elements): RE-363's fragment and reproduce commands name bot…
research(elements): RE-363's commands dispatch from main, since its b…
fix(elements): name the closure (#1496)
fix(elements): the rule covers plumbing fixtures only, the one catego…
feat(ifc): door types' Fire Rating and family types' Manufacturer, re…
research(elements): what separates the water closet tank Revit's expo…
fix(elements): a plumbing fixture whose type draws nothing visible is…
fix(elements): a plumbing fixture whose type draws nothing visible is…
chore(release): prepare v0.16.0 (#1564)
docs: status names what docs.rs built, and the criteria page no longe…
docs: 0.16.1 is the published release, each channel checked from what…