Repository navigation
Closed
Labels
area:elementsWork in the elements area.priority:P3Useful follow-up work after core milestones land.type:bugCorrectness defect or regression.
Description
From #1454's gate (RE-346, Measure run 42107917715). On rac_basic's 2027 save, two doors write no Qto_DoorBaseQuantities Width and Height, where the 2025 and 2026 saves write 0.8 and 2.1 for them.
- Doors 431064 and 485679 (
Single-Flush:800 x 2100). 11 doors write the two quantities on the 2025 and 2026 saves, 9 on the 2027 save. The otherSingle-Flushdoors (422466, 425292, 430997, 431144, 431198) keep them, and 422466 and 430997 have the same type object (ElementId 232780) as the two. - Both doors keep
OverallWidth0.8 andOverallHeight2.1 on all three saves, so their cut loops are read on 2027. Only the quantities go: they are written where the symbol that draws the instance and the instance's type hold the same Width and Height (attach_cut_loop_sizes,type_door_sizes, W7: Revit's base quantities: the census runs, and what is left is on #1046, #1165, #1203, #1207, #1208 and #1209 #1016), so on 2027 that pair is not read for these two, or the two sizes differ. - Not determined which: the symbol that draws these two instances may resolve to another symbol on 2027, or a type or symbol parameter entry may disagree between partition copies there (
type_door_sizesneeds every copy to agree). It may be the same kind of gap as rac_advanced's 2027 save: 8 walls return no native straight-line row, so the doors and windows they host keep the default axes #1475 (a native row that a 2027 save does not return), which is not shown.
None of this is a wrong value: the quantities are left out. #1454's same-project gate counts rac_basic's added property values per year (325 on 2027, 329 on 2026) so that the gap is a number that can only grow.
Done when: the two doors' drawing symbol and its Width and Height entries (and the type's) are read from the bytes on the 2025, 2026 and 2027 saves, with a probe in the style of probe_re318_door_width_sources, and the doors get their quantities on 2027, or a measured negative says why not.
Metadata
Metadata
Assignees
Labels
area:elementsWork in the elements area.priority:P3Useful follow-up work after core milestones land.type:bugCorrectness defect or regression.
Activity
ci: hold pipes as cylinders, pin the walls' boxes, count roofs exactl…
docs: RE-346 records the cylinder check, the stair types, the box pin…
ci: the property floors are the numbers the 2026 and 2027 saves print…
DrunkOnJava commentedon Nov 9, 2026
Progress, from
probe_1489_door_size_entries(branchresearch/1489-door-size-entries, Measure run 42543932759, Autodesk'srac_basic2025, 2026 and 2027).type_door_sizesreads its Width and Height (2.6247 ft and 6.8898 ft) from one partition entry on 2025 and on 2026. On 2027 it finds none, while the same type's other two symbols (490150, 235155) and the type itself still give the same pair. That is why the two doors lose theirQto_DoorBaseQuantities.Partitions/16, as on the earlier saves (208 bytes against 164 on 2025). So the entry looks present, and the value block it sits in isn't attributed to 431054.Next: the bytes between that id and the Width entry on each save, to see what moved the attribution (run 42549634152).
DrunkOnJava commentedon Nov 9, 2026
Progress (Measure run 42551173239). The Width entry of symbol 431054 is still in the 2027 save, in
Partitions/16: the same f64 2.6247 ft, eightffbytes and the Width parameter. The 96 bytes before it are identical to the 2026 save's. What differs is attribution: on 2026 the value scan gives that entry to 431054, and on 2027 to no element, while the same type's other symbols' entries keep their owners.A value entry belongs to the nearest block mark before it whose 8 preceding bytes hold a declared ElementId; a zero there ends a block without an owner. So on 2027 something between the symbol's block mark and its Width entry is now read as an ownerless block start. Run 42552275225 prints the block marks before each entry, with the id each carries, to see which one.
42 remaining items
research(elements): the door size probe names the chain record each W…
research(elements): the door size probe lists what lies between each …
research(elements): the door size probe names the native record whose…
fix(elements): a type's value block ends where the next native record…
docs(re): RE-373, the gate's rac_basic minimum and the docs that named …
docs(re): RE-373 says which releases the length scans read and the AA…
docs(re): RE-373 words the MCP answers' count as Measure prints it (#…
docs(changelog): the #1489 fragment says the Measure run had no racad…
chore(release): prepare v0.16.1 (#1571)
docs: 0.16.1 is the published release, each channel checked from what…
fix(elements): a type's value block ends where the next native record…
docs(re): RE-365 names the length scan as it stands after DrunkOnJava…
feat(ifc): Revit 2017 to 2023 steel beams are drawn as their type's I…