You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Wall base and top passes: a cutter drawn as a box, or whose level is not read, cuts nothing (RE-351 follow-up) #1480
From #1476's second read (RE-351). The wall top and base passes in wall_tops.rs take a cutter's level from its drawn body, and #1476 stops a roof drawn as its record box from cutting a wall's top. Two siblings remain:
Top pass: it does not consult SlabTop::NotRead, so a shape-edited Floor or footing drawn as a box has the same flaw.
Also: a Floor exported as IfcRoof loses its cut (fail-closed), and a Roof exported as IfcSlab keeps the old defect.
Done when: a cutter whose top or underside is not read cuts nothing on either pass, with a counted reason, and no wall on any model with a Revit export moves away from it.
The first of the three asks here, the base pass, is in PR #1953: plate_roofs is threaded through cut_wall_bases, decide_bases and decide_ends into BaseContext, and decide_base skips a named roof that is not a plate, as level_underside already does for the top pass (found again by the batch 9 export audit as #1947 item 5). Its Measure with the held-out models is running (43540737360). The other two asks stay open here:
Left: the top pass consulting SlabTop::NotRead, a top cut at a slab or footing whose outline is not read. That is #1947's item 4, which waits on a count of the top cuts by covering element, with and without an outline.
Closing: the last ask is settled as a measured negative.
The two asks done earlier: #1953 cuts a wall's base at a roof's top only where the roof is a level plate, and #1974 tells a roof by its record class.
The one left was whether the top pass should refuse a slab or footing whose plan outline is not read (drawn as its record box), as it refuses such a roof. Measured with #1947's item 4: a variant that refuses those cutters (research/1947-top-cut-box, Measure 43647353701, unfiltered with holdout) loses walls whose base and top equal Revit's:
model
main
refusing box-drawn slabs and footings
BIM4LCA office, concrete, as built
607
542
BIM4LCA office, concrete, at permit
589
519
BIM4LCA office, timber, as built
598
542
BIM4LCA office, timber, at permit
573
521
held-out Revit 2026 house (counts only)
56
37
BIM4LCA housing, timber, as built / at permit
346 / 340
342 / 336
BIM4LCA housing, concrete, as built / at permit
356 / 330
356 / 330
So Revit cuts a wall's top at a slab or footing that rvt-rs draws as its box, and the box's underside is the level it stops at. A footing drawn as its box is its real shape, as the earlier note on #1947 guessed. The top pass keeps cutting there. Unlike a roof's box, a slab's or footing's box is not a stand-in for a slope.
Activity
DrunkOnJava commentedon Nov 14, 2026
The first of the three asks here, the base pass, is in PR #1953:
plate_roofsis threaded throughcut_wall_bases,decide_basesanddecide_endsintoBaseContext, anddecide_baseskips a named roof that is not a plate, aslevel_undersidealready does for the top pass (found again by the batch 9 export audit as #1947 item 5). Its Measure with the held-out models is running (43540737360). The other two asks stay open here:SlabTop::NotRead(also Batch 9 export findings still to fix: 12 confirmed, 6 to settle with a run #1947 item 4, which waits on a count of the top cuts by covering element, with and without an outline);ifc_type == "IFCROOF".fix(ifc): a wall's base is cut at a roof's top only where the roof is…
fix(ifc): drop the HashSet import export_content.rs no longer uses (#…
fix(ifc): the wall top and base passes tell a roof by its record clas…
DrunkOnJava commentedon Nov 14, 2026
Status on
mainafter v0.23.0. Two of the three asks are done:b3ae8569) cuts a wall's base at a roof's top only where the roof is a level plate.21d310f0, RE-351). The top and base passes tell a roof by its record class, not by the IFC entity it is exported as.Left: the top pass consulting
SlabTop::NotRead, a top cut at a slab or footing whose outline is not read. That is #1947's item 4, which waits on a count of the top cuts by covering element, with and without an outline.DrunkOnJava commentedon Nov 14, 2026
Closing: the last ask is settled as a measured negative.
The two asks done earlier: #1953 cuts a wall's base at a roof's top only where the roof is a level plate, and #1974 tells a roof by its record class.
The one left was whether the top pass should refuse a slab or footing whose plan outline is not read (drawn as its record box), as it refuses such a roof. Measured with #1947's item 4: a variant that refuses those cutters (
research/1947-top-cut-box, Measure 43647353701, unfiltered with holdout) loses walls whose base and top equal Revit's:mainSo Revit cuts a wall's top at a slab or footing that rvt-rs draws as its box, and the box's underside is the level it stops at. A footing drawn as its box is its real shape, as the earlier note on #1947 guessed. The top pass keeps cutting there. Unlike a roof's box, a slab's or footing's box is not a stand-in for a slope.