rac_advanced's 2021 save writes none of its 25 Areas, though the plan topology reads all 25 as the later state #1434

Closed

Description

@DrunkOnJava

On Autodesk's rac_advanced 2021 save rvt-rs writes no Area body: area_without_proven_body 25 (22 boundary_lines_not_readable, 3 named_lines_not_in_scheme_and_level), as on main. The 2015 to 2020 and 2022 to 2027 saves write 25 (#1428, RE-333).

Cause. The save holds both states of the model, so 16 area boundary lines have two disagreeing partition copies. group_arrangement returns Group::Unreadable for a group with one, and locate refuses it before the plan topology is asked. The review of #1371 asked for exactly that order, so this is a decision to reopen, not a bug.

Measured. Measure run 42008543772 (probe_re333_area_plan_topology): the topology's native current copy gives 25 of 25 regions equal to the 2022 and 2023 saves' in vertex count, holes, arcs and area (area to 1e-6).

Open question. May a conflict between the lines' partition copies let the topology draw, where the topology reads only the native current copy and every loop is checked against the area Revit saves for it, while a design option or a stray height still refuses?

Evidence missing. No Revit export of the 2021 state exists.

Done when: the 2021 save writes 25 Areas equal to the 2022 save's (checked by tools/re/areas_across_saves.py extended to the 2021 save), a save with a design-option line still refuses, and the held-out 2021 Areas model shows only in rvt-rs 0.

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:elementspriority:P3type:bug

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions