Skip to content

rvt-schedule's elements CSV: level and rows from the writer's placement (#1412 follow-up) #1417

Closed

Description

@DrunkOnJava

From #1412 (#1327).

#1412 makes the IFC writer's placement decision public (step_writer::placements, storey_of). The MCP server, the diagnostics' storey_bound_elements and the schedule's room rows now read it. A stair or railing part is on its whole's storey, an element in a room on the room's storey, an opening on its host's.

rvt-schedule's elements CSV (elements_csv) still takes an element's level from its own storey_index, and it lists the pieces folded into another element's body as rows of their own. So its level column can disagree with the storey the IFC puts the element in: on the BIM4LCA office as built, 599 rows before #1412's server fix, 542 of them curtain-wall members. It also counts folded pieces the IFC does not write as elements.

Done when: the elements CSV takes each row's level from placements/storey_of and leaves folded pieces out, or lists them marked as folded. The change is measured on the office and the Revit 2025 models with stairs: rows whose level moves, and rows removed. docs/schemas and the CLI docs say what the level column is.

Metadata

Metadata

Assignees

No one assigned

    Labels

    area:ifcpriority:P3type:bug

    Type

    No type

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions