A wall base covered in part: cut over the covered part (RE-337 follow-up) #1411
As built, the BIM4LCA office's Basement walls 2058499 and 2058501 keep their record ends, 0.31 ft short of Revit's. #1398 refuses to carry them on (BodyEndRefusalbase_not_cut_over_the_extended_plan), because the footing beneath covers the extended plan only in part. Their base cut would then be refused and their volume would grow from 4.497 to 6.919 ft³ over Revit's.
Done when: a wall whose base is covered only in part is cut over the part that is covered (RE-336's "covered in part" case), so these two walls can take Revit's end and base together. Otherwise this is recorded as a measured negative.
Activity
docs(ifc): RE-349 report, addendum, changelog and the office's witnes…
Merge the base cover branch (#1411) into the end levels branch
fix(ifc): a whole cover decides before a partial one, rings are turne…
fix(ifc): count the walls that take the end and base rules and the en…
docs(reports): RE-348 and RE-349 hold the verdict run of the marker p…
feat(ifc): a wall base covered in part is cut over the covered part, …