From #1388 (RE-336, Measure run on d853a62). After the sloped-footing base cut, 12 of the 14 raised Basement walls of the BIM4LCA office as built (12 of 16 at permit) have Revit's lowest point. The rest do not: walls 2057668 and 2057670 as built (and 2058499 and 2058501 at permit) are 0.123 ft (0.044 ft) off. Their plan ends 0.29 ft (0.09 to 0.10 ft) short of Revit's at the footing's low end, so the base is cut where the footing is higher.
This is a wall-plan-length problem, not a footing one: where the wall ends against the joined element at that end.
Done when: these walls' plan ends are read from the bytes and their lowest points match Revit's on both office files (wall_heights_vs_ifc), with no other wall's length or base moving.
Closed 2026-11-05. Walls 2057668 and 2057670 match Revit's lowest point on both office files (RE-337, #1398, which ships as a labelled approximation, Griffin 2026-11-05). What is left is tracked: walls 2058499 and 2058501 at permit on #1409, the second step of the wall ends on #1410, and walls 2058499 and 2058501 as built on #1411.
Activity
Revert "fix(elements): a wall whose T-joint host lies above its base …
fix(elements): a wall whose end candidates stand above its base ends …
Revert "fix(elements): a wall whose end candidates stand above its ba…
fix(ifc): a wall with an edited elevation profile that stops short of…
fix(ifc): a floor with shape-edited corners is drawn along its sloped…
chore(ifc): temporary end-pass diagnostics (#1396)
chore(ifc): temporary rejection diagnostics (#1396)
Revert "chore(ifc): temporary rejection diagnostics (#1396)"
Revert "chore(ifc): temporary end-pass diagnostics (#1396)"
fix(ifc): the end pass reads record-box walls and walls that reach on…
8 remaining items
fix(ifc): name the end pass's reach check apart from the step pass's (#…
docs: RE-337 measures the stepped end, the openings kept in place and…
docs: RE-337 names the stepped-body path and the beneath solid no mea…
fix(ifc): the added end stops below any wall that stands in it and re…
fix(ifc): a beneath wall with a profile of its own is read whether or…
docs: RE-337 measures the block stopped below the walls in its way an…
docs: the in-the-way check reads only the walls the pass reads, and s…
feat(ifc): an end whose block stops below the wall's top is labelled …
docs: RE-337 ships the end as a labelled approximation and names what…
docs: RE-337 cites the final-head runs against main with #1401 and th…
fix(ifc): a wall with an edited profile cut back from inside the wall…