Skip to content

Walls cut by an embedded curtain wall: a byte signal for which hosts keep their end stubs (RE-335) #1385

Closed

Description

@DrunkOnJava

From RE-335 (#1383, Measure run 41906631624).

Six walls of the BIM4LCA office as built are drawn 8.2021 ft taller at the base than Revit's body. Each hosts an embedded curtain wall (WallEmbedWallGStep, m_bCutSomething 1) that is 8.2021 ft tall from the wall's base, and Revit's body is the host less that curtain wall's prism.

Hosts 2098938 and 2103576 host the same embedded curtain wall (0.051 to 0.949 of a 20.54 ft host). Revit cuts 2098938's body to the strip over the curtain wall (23.42 ft³), but 2103576 keeps its end stubs (32.08 ft³). The report infers, without having read it, that 2098938's end stubs lie in the columns it has CutPairGStep partners with (1927726, 1927727).

Done when: a byte-level reading separates the two cases (for example the cut partners' volumes, or whatever removes the stubs), and the six hosts draw Revit's stepped base. Hosts such as 2103576 and 2177158 must not change. If no signal is found, a measured negative goes in a report.

Activity

  1. added
    area:elements
    priority:P2
    type:research
    on Nov 4, 2026
  2. added 19 commits that reference this issue on Nov 5, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment