Skip to content

W7: single-layer slabs' Width and Length, sloped floors' Depth and the stair landings' volume (RE-295, RE-298) #1208

Open

Description

@DrunkOnJava

Part of W7 (#1016). Evidence: reports/element-framing/RE-295-floor-net-volume.md, reports/element-framing/RE-298-slab-depth-roofs.md.

Written

A floor's NetVolume (its GrossArea times its type's layers' total thickness, where its native record holds no cutting step) and, of more than one layer, its Width (RE-295); a level floor's Depth (its last layer's) and GrossVolume, and a flat roof written as a slab's GrossArea, Depth, GrossVolume and, where nothing cuts it, NetVolume (RE-298).

Not written

On the BIM4LCA office as built:

  • Width and Length of a floor, roof or landing of one layer (20 Width values): Revit's value is the profile's extent along the extrusion's Y axis (Width) and X axis (Length) in the plane it extrudes from, so it turns with each slab and with the plane Revit picks (a 6.025 by 2.76 m landing has Width 6.025 and Length 2.7605, a 1.5 by 6.47 m floor has Width 1.5), and a rectangular AP-2 landing has neither as built and both at permit. A roof of several layers has the profile's extent too (YP-3, 12.35 m).
  • NetVolume of the 21 stair landings Revit draws as a mesh (300 mm Thickness): 0.5028 to 0.5121 m3 where rvt-rs's body, its slab (RE-214), has 0.5268 or 0.5307; the stair's runs cut them.
  • Depth of the 8 sloped floors (4 AP-1 base slabs, 4 AP-3 gutter floors): the type's thickness times the cosine of a slope that rvt-rs draws level (RE-238).
  • Perimeter, Length (Revit writes Perimeter in feet in a millimetre file, RE-235 §5), and the single Non-Monolithic Landing.

What would close it

The slope of a sloped floor from its record; the orientation of the extrusion plane Revit picks; a body for the stair landings that the stair's runs cut.

Activity

  1. added
    area:ifc
    priority:P1
    type:feature
    on Oct 30, 2026
  2. DrunkOnJava commented on Nov 14, 2026

    @DrunkOnJava
    OwnerAuthor

    Status on main after v0.23.0. Two of the "Not written" items have since landed:

    Still not written, and what keeps this open:

    • Width and Length of a one-layer floor, roof or landing: the extrusion plane Revit picks is not read.
    • NetVolume of the 21 stair landings Revit draws as a mesh: the landing's body is not cut by the stair's runs.
    • A floor's Length, and the single Non-Monolithic Landing.
  3. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    Width and Length of a one-layer slab: which axes Revit's export takes. Partly answered, and a measured negative.

    A trace (tools/re/trace_1208_slab_axes.py on research/1193-short-mullions, not to land; Measure 43669813095, main afbaabb5) reads every slab and covering with a Width or Length base quantity in Revit's export. For each it prints the axes the body extrusion is drawn in, the profile's extents along them, and the outline's first edge.

    • One-layer slabs: Width is the profile's extent along the extrusion profile's Y, and Length its extent along X. For example, AP-2 1439250 has profile X extent 9.0567 ft = Length and Y extent 19.7671 = Width, and TK-1 1752566 has 21.2348 = Length and 4.9213 = Width. For a slab of several layers, Width is the layers' thickness, as RE-295 has it.
    • Revit's profile X runs along its own outline's first edge on 114 of 117 (office as built), 96 of 98 (office permit) and 73 of 83 (concrete housing as built). On Snowdon Towers Architectural, read locally from Revit's export, it holds on 141 of 150 straight outlines and 41 of 44 coverings; the longest edge does much worse (47 of 150). Which way X runs varies by slab: ±model Y on most of the office's, ±model X on others.
    • The first edge is not the first-drawn sketch line. A probe printed each owner's two lowest-ElementId sketch lines with the ends each is stored with (probe_1208_first_sketch_lines, research/358-walls-drawn-whole at de56abf9, run 43670203931). On the office as built, Revit's first edge is the lowest line on 9 slabs (3 in its stored sense, 6 reversed), the second-lowest on 30, a line parallel to the lowest elsewhere on 32, and neither on 37; 35 have no sketch lines read. The permit file and the concrete housing read alike. Even four-line rectangles start on the third or fourth line.

    So where Revit's outline starts, and with it which plan axis is Length, is not decided by the sketch's drawing order. rvt-rs's own ring starts on an edge parallel to Revit's first edge on only 45 of 117. The measured part is what Width and Length are once the axes are known. The axes themselves need a new signal, likely from the slab's solid. revit-ifc's container path computes a floor's profile from its top face (RoofExporter.ExportRoofOrFloorAsContainer, CLEANROOM.md source 5); its ordinary floor path is not read yet. Nothing is written.