Status 2026-11-11. Item 1 landed: a joined column's Length where RE-291 takes it (#1287). Item 3 landed in part with RE-353 (the CrossSectionArea and NetVolume of 17 of the 18 cut columns), and a column drawn from a saved mesh now gets the four an extruded column holds (Length, CrossSectionArea, OuterSurfaceArea, GrossVolume) where its mesh is a prism along the vertical (RE-424, #1708: equal to Revit's on 340 of the timber office's 344 CrossSectionArea as built, none different). Left: the round column (item 2) and the box-drawn columns, whose box equals Revit's on 46 of the timber housing's 50 (#1705), with the check that a box-drawn column's type holds a b (and h) equal to its box's sides.
What is left
RE-291 (#1204, #1046) writes CrossSectionArea, OuterSurfaceArea, GrossVolume and NetVolume as the record box's on a column drawn as that box whose type is a plain rectangle (parameters b, or h and b, equal to the box's sides), joined by no clean pair or by clean pairs where nothing cuts it or crosses an end of it: 199 of the BIM4LCA office's columns as built and 265 at building permit, Revit's on every one. Gaps that remain in W7's column quantities:
- A joined column's
Length. The maintainer left it out (2026-10-26) because Revit's export draws 18 columns at permit as a cut mesh with noLengthand nothing told them apart. RE-291 §2 finds what does: each of the 18 has aCutPairGStepslab whose span crosses its top, and none of the 327 extruded columns does. On the columns the RE-291 rule takes that a clean pair joins, Revit writes aLengthon every one (186 of 186 as built, 250 of 250 at permit), equal to the box's height. Writing it there would add 436 quantities, none Revit omits. This reverses the premise of the 2026-10-26 decision, so it is the maintainer's call; the code would be one more property inexport_content/column_quantities.rs. - The round column (
Round Column:PI-6, 3053209, one on each file). Its type holds aDiameterand nob, so the box rule leaves it out. Revit'sCrossSectionAreais 0.01766 m² (the circle's) against the box's 0.0225; itsGrossVolumeandNetVolumediffer from each other (0.105959 and 0.106005 m³), so the circle's formulas would need checking against the second. rvt-rs also draws it as a box (W6). Other families whose captions are notbandhstay out until a file with one is measured. - The 18 meshed columns'
CrossSectionAreaandNetVolume, which Revit writes (about 3.3 m² and 0.62 m³ on 17 of them) and the box does not give: Revit's cut mesh.
Evidence
reports/element-framing/RE-291-column-cut-slabs.md, probes/examples/probe_re291_column_pairs.rs, probes/examples/probe_re291_column_type_parameters.rs, Measure 41139043243 and 41140980550.
Activity
DrunkOnJava commentedon Oct 30, 2026
Item 2, measured:
probes/examples/probe_re291_column_type_parameters.rs(Measure 41140980550) prints the length parameters each column type holds, with the captions of theirParamElemFamilyelements. On the BIM4LCA office as built:Round Column:PI-6(type 3053174, the one round column) holds one length parameter, captionedDiameter(0.492126 ft, its box's side).Concrete-Square-Columntypes (PI-1, PI-7, PI-8, PI-9) hold one, captionedb, equal to both sides of their columns' boxes.Concrete-Rectangular-Columntypes (PI-3, PI-10, PI-11) hold two,handb, equal to the box's two sides.b,Ht,tandkr(RE-221).So a section check that a box-drawn column's type holds a
b(and anh) equal to its box's sides is positive evidence of a rectangle, and the round column fails it. It rests on the captions the family author gave (bandhare Revit's own content's), which is what RE-221 already does for the hollow sections. With it the 13 (as built) and 15 (at permit) box-drawn columns no clean pair joins get the box's four quantities, and the joined-column rule gets a guard against a round column it has not met. Not implemented yet.[-]W7: a joined column's Length, which RE-291 now separates, and the box-drawn columns no clean pair joins[/-][+]W7: a joined column's Length, which RE-291 now separates, and the round column[/+]feat(ifc): write the base quantities of a joined column that nothing …
docs: the contribution map lists #1203 and #1207 to #1209, and drops #…
docs(release-criteria): W7 and the evidence page count the joined col…
docs(release-criteria): the joined column's Length is no longer liste…
feat(ifc): a column a clean join pairs with carries its Length, the b…
chore(release): prepare v0.13.0 (#1303)
[-]W7: a joined column's Length, which RE-291 now separates, and the round column[/-][+]W7: the round column and the meshed columns' values, and the section check on box-drawn columns[/+]research(ifc): a probe for the door types' value blocks and every sla…
feat(ifc): a round column no pair joins gets its OuterSurfaceArea, th…
18 remaining items
research(re): the round-column probe prints the Qto_ColumnBaseQuantit…
docs(ifc): the column quantity repair is RE-416, RE-414 being the fla…
docs(re): RE-411 runs RvtIO's round-column rule beside RE-353's on 6,…
docs(re): RE-416 records that the repair takes exactly 24 columns' fo…
fix(ifc): a column's box quantities hold only where its saved mesh is…
docs(re): RE-424 reports a column's four base quantities from the pri…
docs(re): RE-424 reports the post-#1701 timing and the samples' cross…
feat(ifc): a column drawn as its type's rectangle gets the base quant…
feat(ifc): a column whose mesh is a vertical prism gets the Length, C…
feat(ifc): an Area's Qto_SpaceBaseQuantities.Height is its body's hei…
docs: 0.19.0 is the published release, each channel checked from what…
docs(re): RE-411 states only what RvtIO's reader decodes for the two …
docs(re): RE-411's two Snowdon Towers columns are not taken as round …
fix(ifc): a column drawn from its saved mesh takes the mesh's height …