Skip to content

W7: the round column and the meshed columns' values, and the section check on box-drawn columns #1203

Closed

Description

@DrunkOnJava

Status 2026-11-11. Item 1 landed: a joined column's Length where RE-291 takes it (#1287). Item 3 landed in part with RE-353 (the CrossSectionArea and NetVolume of 17 of the 18 cut columns), and a column drawn from a saved mesh now gets the four an extruded column holds (Length, CrossSectionArea, OuterSurfaceArea, GrossVolume) where its mesh is a prism along the vertical (RE-424, #1708: equal to Revit's on 340 of the timber office's 344 CrossSectionArea as built, none different). Left: the round column (item 2) and the box-drawn columns, whose box equals Revit's on 46 of the timber housing's 50 (#1705), with the check that a box-drawn column's type holds a b (and h) equal to its box's sides.

What is left

RE-291 (#1204, #1046) writes CrossSectionArea, OuterSurfaceArea, GrossVolume and NetVolume as the record box's on a column drawn as that box whose type is a plain rectangle (parameters b, or h and b, equal to the box's sides), joined by no clean pair or by clean pairs where nothing cuts it or crosses an end of it: 199 of the BIM4LCA office's columns as built and 265 at building permit, Revit's on every one. Gaps that remain in W7's column quantities:

  1. A joined column's Length. The maintainer left it out (2026-10-26) because Revit's export draws 18 columns at permit as a cut mesh with no Length and nothing told them apart. RE-291 §2 finds what does: each of the 18 has a CutPairGStep slab whose span crosses its top, and none of the 327 extruded columns does. On the columns the RE-291 rule takes that a clean pair joins, Revit writes a Length on every one (186 of 186 as built, 250 of 250 at permit), equal to the box's height. Writing it there would add 436 quantities, none Revit omits. This reverses the premise of the 2026-10-26 decision, so it is the maintainer's call; the code would be one more property in export_content/column_quantities.rs.
  2. The round column (Round Column:PI-6, 3053209, one on each file). Its type holds a Diameter and no b, so the box rule leaves it out. Revit's CrossSectionArea is 0.01766 m² (the circle's) against the box's 0.0225; its GrossVolume and NetVolume differ from each other (0.105959 and 0.106005 m³), so the circle's formulas would need checking against the second. rvt-rs also draws it as a box (W6). Other families whose captions are not b and h stay out until a file with one is measured.
  3. The 18 meshed columns' CrossSectionArea and NetVolume, which Revit writes (about 3.3 m² and 0.62 m³ on 17 of them) and the box does not give: Revit's cut mesh.

Evidence

reports/element-framing/RE-291-column-cut-slabs.md, probes/examples/probe_re291_column_pairs.rs, probes/examples/probe_re291_column_type_parameters.rs, Measure 41139043243 and 41140980550.

Activity

  1. added
    area:ifc
    priority:P1
    type:feature
    on Oct 30, 2026
  2. DrunkOnJava commented on Oct 30, 2026

    @DrunkOnJava
    OwnerAuthor

    Item 2, measured: probes/examples/probe_re291_column_type_parameters.rs (Measure 41140980550) prints the length parameters each column type holds, with the captions of their ParamElemFamily elements. On the BIM4LCA office as built:

    • Round Column:PI-6 (type 3053174, the one round column) holds one length parameter, captioned Diameter (0.492126 ft, its box's side).
    • Concrete-Square-Column types (PI-1, PI-7, PI-8, PI-9) hold one, captioned b, equal to both sides of their columns' boxes.
    • Concrete-Rectangular-Column types (PI-3, PI-10, PI-11) hold two, h and b, equal to the box's two sides.
    • The hollow sections hold b, Ht, t and kr (RE-221).

    So a section check that a box-drawn column's type holds a b (and an h) equal to its box's sides is positive evidence of a rectangle, and the round column fails it. It rests on the captions the family author gave (b and h are Revit's own content's), which is what RE-221 already does for the hollow sections. With it the 13 (as built) and 15 (at permit) box-drawn columns no clean pair joins get the box's four quantities, and the joined-column rule gets a guard against a round column it has not met. Not implemented yet.

  3. changed the title [-]W7: a joined column's Length, which RE-291 now separates, and the box-drawn columns no clean pair joins[/-] [+]W7: a joined column's Length, which RE-291 now separates, and the round column[/+] on Oct 30, 2026
  4. changed the title [-]W7: a joined column's Length, which RE-291 now separates, and the round column[/-] [+]W7: the round column and the meshed columns' values, and the section check on box-drawn columns[/+] on Nov 5, 2026
  5. 18 remaining items