Summary

On the BIM4LCA office, a handful of property values Revit's export writes have no rule in rvt-rs yet. They are smaller than the clusters tracked elsewhere (#1016 and #1046 for quantities, #1185 to #1187 for type objects, stairs and curtain members), so they are collected here to keep W7 of the 1.0 release criteria complete.

Where things stand

Office as built, from the property census (tools/re/psets_vs_ifc.py, Measure run 41129228138 on main at b09310a):

Property Missing Notes
Pset_ColumnCommon.Slope 73 A measured negative (RE-277): six columns have identical native records in both office files, yet Revit gives them Slope at permit only. No rule over a column's own record can be exact, so this needs a decision or a new signal.
Pset_EnvironmentalImpactIndicators.Reference 28 On openings (VP-1 on 27).
Pset_MemberCommon.Span 18 Curtain mullions whose span RE-226 does not read.
Pset_SlabCommon.PitchAngle 8 Sloped slabs; RE-238 writes 0 where a slab's top is level.

Done when

Each value is written where a rule from the model gives Revit's value on every element it covers, with nothing different and nothing Revit's export omits. Anything left out is reported with its evidence and, where needed, the maintainer's decision.

Where to start

Run Measure with -f psets_missing=<set>.<property> to list every object missing a property, then compare with the readers named in each report.

Activity

  1. added
    area:ifc
    priority:P2
    type:feature
    on Oct 30, 2026
  2. DrunkOnJava commented on Oct 31, 2026

    @DrunkOnJava
    OwnerAuthor

    Moved here from #1186: NumberOfTreads on one office stair and two of its flights (RE-217's residual, 34 of 35 flights Revit's), with every other stair and flight value now Revit's.

  3. 15 remaining items

  4. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    Correction to the mullion Span count here. On main (ac1ff346, Measure 43662654246 base side, psets_missing=Pset_MemberCommon.Span), the turned mullions all have their Span. The office as built misses it on 6 mullions, 9,996 of 10,003 equal and 1 different, and all six are 0.1 m pieces of the 50 x 50 mm mullion (3024609, 3028418, 3028419, 3028723, 3028885 and 3028886), whose Span Revit writes as 100.85 mm. At permit it is 6 missing again, and on each timber office file 4. #2028, built on the old count of 12 turned mullions, moved nothing and is closed, and #2032 corrects docs/evidence.md. What is left of the Span item is these short pieces: why their Span is not written, when their Length is, is the next thing to read. The column Slope and the spiral stair's NumberOfTreads items are unchanged.

  5. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    Correction to my note above: "the turned mullions all have their Span" is more than the census shows. The six missing are 0.1 m pieces, and whether they are turned about their own axis is not read yet. If they are, they are among RE-226's 12, and #2028's axis was reached and refused later in the mesh pass. If not, the cause is another one. Reading each piece's transform axes is the next step either way.

  6. DrunkOnJava commented on Nov 15, 2026

    @DrunkOnJava
    OwnerAuthor

    The six short mullions without a Span are not turned about their own axis. Measure 43667695517 ran a trace (tools/re/trace_1193_short_mullions.py on research/1193-short-mullions, not to land) on main afbaabb5 over the four office files:

    • Where they lie. All six (3024609, 3028418, 3028419, 3028723, 3028885, 3028886; four of them on each timber office file) are horizontal pieces of the 50 x 50 mm mullion running diagonally in plan. In Revit's export their local Z is (0.712, −0.702, 0) or close to it, and their X is vertical. Revit writes Span = Length = 0.330865 ft (100.85 mm).
    • What rvt-rs reads. Its export places each at identity axes, drawn from its saved mesh (BodySource saved_graphics_mesh), with no Length and no Span. scan_transforms_in_layout finds no transform in their records, so attach_curtain_axes gives no axes and add_mullion_span has no length to take. They also lack NetSurfaceArea on both offices, like the 18 mullions "whose record names no axis" of Mullion NetSurfaceArea: 120 mullions of the concrete office and 127 of the timber office, as built, are still without a value after RE-441 #1798 and RE-438.

    What is left of the Span item is why these records give no transform. I haven't checked tag by tag that they are among RE-438's 18.