Repository navigation
Description
On the BIM4LCA office (Revit 2024), rvt-rs draws 78 of the 579 walls Revit's export gives a Qto_WallBaseQuantities.Height taller than Revit draws them as built, and 84 of 565 at building permit. rvt-rs's wall body is as tall as the wall's record box. On each of these walls Revit's own body is shorter, and its vertical span is exactly Revit's Height.
Measured by tools/re/wall_height_vs_qtos.py on examples/probe_re251_wall_numbers.rs's output (RE-257). The last column is the vertical span of Revit's body, from IfcOpenShell's geometry; all values are in feet:
| Wall (as built) | rvt-rs | Revit's Height |
Revit's body | Revit draws it as |
|---|---|---|---|---|
| 1632093, 1636266, 1636317, 1636357 | 19.587 | 10.344 | 10.344 | SweptSolid |
| 1479272, 1630142 | 19.587 | 16.404 | 16.404 | Tessellation |
| 1457513, 1536395, 1656495 | 14.173 | 11.253 | 11.253 | Tessellation |
- As built, 32 of the 78 are SweptSolid in Revit's export and 46 Tessellation; at permit, 33 and 51.
- On 77 of the 78, the wall's saved Unconnected Height (-1001101) is as tall as rvt-rs's body. So the record box and the saved parameter both describe the uncut wall.
- No field of the wall's native record separates these walls from the 501 whose height is Revit's. The best single value, the roof join's
JoinToRoofGStep.m_leadingIdx = -1, is on 61 of them and on 30 others. - On puzzbobb's R2025 models (Revit 2025), rvt-rs's depth is Revit's
Heighton all 117 walls, the 32 attached to roofs included.
What is owed: read what cuts these walls' solids in the office's Revit 2024 records (a roof or floor join's cut, or an attachment the record box does not follow), so the body and then its Height are Revit's. The Tessellation ones are probably cut by a sloped roof. On the SweptSolid ones, Revit's body is a plain extrusion about half the record box's height.
Runs: Measure 40501460421 (office, with Revit's bodies) and 40490349469 (office and R2025).
Blocks W6 of docs/release-1.0-criteria.md ("every element's body is Revit's own shape"), and through it W7 (the walls' Height). Report: RE-257 (#1068).
Activity
research(elements): a wall's Height is Revit's body's span; rvt-rs dr…
docs: the gap lists name the 78 office walls drawn taller than Revit's (
docs: the docs name v0.10.0 as the latest release, each channel check…
docs: the gap lists name the 78 office walls drawn taller than Revit's (
research(elements): a scorer compares each wall's base and top with R…
research(elements): the wall height scorer tests whether floors, roof…
DrunkOnJava commentedon Oct 27, 2026
Narrowed with
tools/re/wall_heights_vs_ifc.py(branchre/wall-cuts). It meshes everyIfcWallin rvt-rs's IFC and Revit's and compares each body's lowest and highest point by Tag. Measure 40509396187:Next: test whether the floor, roof or footing a wall's end crosses gives Revit's cut. The scorer now counts that against Revit's ends (run 40510514300).
research(elements): the wall height scorer names the floor, roof or f…
91 remaining items
docs: ducts, fittings, opening cut loops, the stub wall and family re…
DrunkOnJava commentedon Nov 15, 2026
Where this stands on
main(e6201f4c), read on Measure 43662517205 (both office files,wall_heights_vs_ifcandwall_top_cover_vs_ifc, with Revit's IFC4 exports).The issue's own count is gone.
wall_heights_vs_ifcgives every wall Revit's lowest and highest point: 607 of 607 as built and 589 of 589 at building permit. The 78 and 84 walls this issue opened with, whose bodies were as tall as their record boxes, are no longer taller in their span.What is left is the shape of the top over the plan.
wall_top_cover_vs_ifcsamples each wall's top on a grid of plan points against Revit's body. 590 of 607 walls are equal everywhere as built (RE-320 had 583), and 579 of 589 at permit (571).So the remaining work is RE-320 §7's: the layers Revit ends at different heights (the four finish-layer walls), and a top Revit cuts at a height no join names (2602205, 2601954, 1494012). Plus #1474's pair and three walls off by a few sample points. Wall
Heighton the stepped walls is still not written, for the reason RE-320 §5 gives. This stays open for those. A per-layer top rule would rest on the four finish-layer walls of this one project.