@DrunkOnJava

tools/re/psets_vs_ifc.py, the W7 property census, reads only sets related through IfcRelDefinesByProperties. A type object holds its sets itself (IfcTypeObject.HasPropertySets, RE-210 §2), so every property Revit's export writes on a type is outside the census on both sides: neither scored nor counted as missing.

tools/re/set_census.py (RE-239, PR #1017; Measure run 40278970448) now counts both. Values in Pset_ sets on type objects:

model on type objects
BIM4LCA office as built 1,618
BIM4LCA office at permit 1,696
RE1 Architecture 11
R2025 Rooms_Stairs 17

On the office they are the entities' own common sets (Pset_MemberCommon on 670 member types, Pset_ColumnCommon on 279 column types, Pset_DoorCommon on 95 door types, Pset_PlateCommon on 154 plate types, Pset_StairFlightCommon and Pset_StairCommon on stair and flight types, ...) and Pset_ManufacturerTypeInformation on 11 family types.

Owed: psets_vs_ifc keys a type object by its Tag (its ElementId) under its own prefix and scores its HasPropertySets like an occurrence's sets, so W7's census covers what Revit writes on types; then the W7 row of docs/release-1.0-criteria.md states the type values measured.