You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
W7: Revit's base quantities: the census runs, and what is left is on #1046, #1165, #1203, #1207, #1208 and #1209 #1016
Status 2026-11-05. The census exists (tools/re/qtos_vs_ifc.py, tools/re/set_census.py) and docs/release-1.0-criteria.md carries its current counts. What remains is on #1046, #1165, #1203, #1207, #1208 and #1209; this stays open as W7's quantity umbrella until they close.
W7 of docs/release-1.0-criteria.md asks for every property set, property and quantity Revit's export writes. The quantities have never been measured: tools/re/psets_vs_ifc.py, the W7 census, reads only IfcPropertySets named Pset_, so an IfcElementQuantity is not counted on either side.
tools/re/set_census.py (RE-239, Measure run 40275298500) counts what Revit's exports write:
model
Qto_ sets
objects
values
BIM4LCA office as built
18
12,910
52,038
BIM4LCA office at permit
18
12,951
52,193
puzzbobb's R2025 models
1,543 in all
RE1 (IFC2X3), Core Interior
0
0
0
On the office as built:
set
objects
values
Qto_MemberBaseQuantities
10,003
40,012
Qto_WallBaseQuantities
607
5,424
Qto_ColumnBaseQuantities
279
1,395
Qto_OpeningElementBaseQuantities
411
1,190
Qto_DoorBaseQuantities
269
853
Qto_WindowBaseQuantities
269
807
Qto_SpaceBaseQuantities
308
678
Qto_PlateBaseQuantities
260
517
Qto_CoveringBaseQuantities
111
359
Qto_SlabBaseQuantities
63
340
Qto_CurtainWallQuantities
220
220
seven more (stair flights, beams, pipe segments, railings, proxies, ramp flights, air terminals)
110
243
rvt-rs writes a few today (Qto_SlabBaseQuantities from from_decoded, pipe and duct segment quantities in export_content), unmeasured against these.
What is owed:
A quantity census beside psets_vs_ifc: equal (in each file's own units, within the scorers' tolerance), different, missing, values Revit does not write, per (set, quantity) and per entity.
revit-ifc (CLEANROOM.md source 5) computes these from the geometry it exports, so each quantity follows from a body rvt-rs already draws exactly or from a stored value; a quantity of a body that is not yet Revit's own waits for that body (W4, W6), and is reported as such rather than computed from an approximation.
Qto_DoorBaseQuantities.Perimeter (Revit's export writes it on 46 of the BIM4LCA office's 269 doors as built, 42 on the timber office and 14 on the concrete housing; rvt-rs writes none): what the value is, and why it stays out.
On all 46 doors of the office as built it is the perimeter of the profile of the last item of the door's Body representation in Revit's export (the last extruded solid of the mapped representation), equal to a relative 1e-6 on 46 of 46, checked on the STEP text of the reference IFC.
It is not 2 × (Width + Height) of the same set on any of the 46, and two door types of one size get different values (both 1,800 × 2,100 mm: 3,764 mm and 1,810 mm), so neither the type's size nor the opening gives it. Which solid comes last differs by family: a threshold on one type, a leaf on another.
rvt-rs draws a door from the mesh Revit saved and decodes none of the solids Revit's export splits a door into, so no rule it can compute reaches the value. Nothing is written (fail closed).
Windows: Revit's export writes no Qto_WindowBaseQuantities.Perimeter on the office, and the census shows none on the timber office or the housing.
Not checked: the 42 and 14 doors of the timber office and the housing against the same reading (their reference IFCs were not read here), and whether the order of a door's solids can be read from the family's own records. Found in the worker pilot (a worker traced 6 doors by hand; the 46 of 46 is a script over the reference IFC).
Activity
chore(tools): the quantity census scores an IFC2X3 export's segment l…
docs(research): values a project's own property set file places are o…
chore(tools): the quantity census accepts the writer's micrometre rou…
docs: W7 states the quantities measured (#1016)
chore(tools): a quantity census beside the property-set one, run by M…
docs: the supported profile, W7 and the changelog name the mullions' …
feat(ifc): a curtain mullion's Qto_MemberBaseQuantities.Length is its…
fix(ifc): a door's and a window's base quantities take the size of th…
fix(ifc): a door's or window's base quantities are written only where…
docs: W7 states the properties and quantities missing on the office, …
feat(ifc): a wall's Width base quantity is its type's thickness; its …
286 remaining items
merge: main into feat/1016-column-quantities (#1016)
feat(ifc): a column whose mesh is a vertical prism gets the Length, C…
feat(ifc): a column drawn as its type's rectangle gets the base quant…
DrunkOnJava commentedon Nov 11, 2026
Qto_DoorBaseQuantities.Perimeter(Revit's export writes it on 46 of the BIM4LCA office's 269 doors as built, 42 on the timber office and 14 on the concrete housing; rvt-rs writes none): what the value is, and why it stays out.Bodyrepresentation in Revit's export (the last extruded solid of the mapped representation), equal to a relative 1e-6 on 46 of 46, checked on the STEP text of the reference IFC.Width+Height) of the same set on any of the 46, and two door types of one size get different values (both 1,800 × 2,100 mm: 3,764 mm and 1,810 mm), so neither the type's size nor the opening gives it. Which solid comes last differs by family: a threshold on one type, a leaf on another.Qto_WindowBaseQuantities.Perimeteron the office, and the census shows none on the timber office or the housing.Not checked: the 42 and 14 doors of the timber office and the housing against the same reading (their reference IFCs were not read here), and whether the order of a door's solids can be read from the family's own records. Found in the worker pilot (a worker traced 6 doors by hand; the 46 of 46 is a script over the reference IFC).
feat(ifc): a spiral stair flight gets its Pset_StairFlightCommon.Numb…
feat(ifc): a curtain wall's Length is the location curve its record n…
feat(ifc): a shading device carries its type's name as Pset_ShadingDe…
fix(ifc): a floor sketch opening gets its Area only with more than fo…
feat(ifc): a hollow-section column's NetVolume is the volume Revit co…
feat(ifc): a building element proxy gets its NetVolume from its saved…
feat(ifc): a curtain mullion turned near 45 degrees about its own axi…
feat(ifc): an Area's Qto_SpaceBaseQuantities.Height is its body's hei…
fix(ifc): a floor sketch opening that is not a rectangle carries its …
fix(elements): a wall, floor, ceiling or roof type edited since an ea…
fix(ifc): Revit 2015 to 2023 doors and windows cut the outline their …