You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
R2004 (AC1018) common object header mis-parses: ~20 'Bit cursor exhausted' errors per R2004 sample, independent of the R2007+ string-stream work #24
After #23 (R2007+ string-stream ports) the aggregate error count is 94, and 60 of them are the three R2004 samples (*_2004.dwg, ~20 each), mostly Bit cursor exhausted: wanted 8 bits, 4 bits remain inside the common entity/object preamble. R2010/R2013 samples now decode with zero errors, so this is specific to the AC1018 object header layout (spec §19.1 / §19.4.1 for R2004: no string stream, handle stream at the end, obj_size semantics differ from R2007+).
Biggest remaining lever on measured coverage (R2004 files sit at 2.5%). Do: dump one R2004 LINE with examples/dump_line_payload.rs, walk the preamble bit-by-bit against §19.4.1, find where the R2004 path diverges (likely the entmode/num_reactors/xdic/nolinks block or the obj_size handling), fix with a BitWriter-built test, re-run coverage_report and paste the table.
Activity
fix(entities): MTEXT and friends read their TV fields from the R2007+…