Do not report "Server died" when only the liveness check failed

Related: #110479

Changelog category (leave one):

  • CI Fix or Improvement (changelog entry is not required)

Changelog entry (a user-readable short description of the changes that goes into CHANGELOG.md):

...

Description

Stateless tests (amd_tsan, flaky check) on #110479 @ 038667a9c024 reported a single
failing leaf Server died while its own aggregate said Failed: 0, Passed: 3872. The server
did not die: no <Fatal> line, no sanitizer report, empty dmesg, clean shutdown. The
--hung-check liveness probe failed and the run was aborted.

Report:
https://s3.amazonaws.com/clickhouse-test-reports/json.html?PR=110479&sha=038667a9c024695126415fe5f37b76f7a06662fa&name_0=PR&name_1=Stateless%20tests%20%28amd_tsan%2C%20flaky%20check%29

Root cause: tests/clickhouse-test collapses every in-band abort cause into
STOP_TESTING_EXIT_CODE = 2, and the job side appends Server died for that code
unconditionally. Master already carved two causes out of code 2 for this reason; this is
the third.

This adds HUNG_CHECK_EXIT_CODE = 5 and FailureReason.LIVENESS_CHECK_FAILED, with the leaf
Server liveness check failed at status FAIL. All four sites that conclude SERVER_DIED from
a failed probe are changed; the site concluding it from a <Fatal> line is untouched, and its
neighbour becomes an elif of it so fatal evidence is never downgraded. The stop cause travels
through one locked first-writer-wins carrier, replacing a global_time_limit_reached flag.

The leaf names the observation, not a diagnosis: check_server_liveness also fails on a
non-200 response. It is a NEW CIDB test_name. The aggregate stays FAIL, so bugfix
validation still counts a hang as a repro.

Not claimed: a remaining Server died row still does not prove a death. Code 2 is generic, and
a worker seeing a <Fatal> line reaches the parent through stop_tests(), exiting 143 -
correct there, but decided outside the carrier.

Validation: +50 tests asserting the process exit code end to end - the same command exits 2 on
master and 5 here. Each changed site has a mutation arm reddening a named case. ci/tests: 705
passed, 655 on master.

Successor to #112952, not an extension: that PR deliberately excludes exit code 2. Both touch
the same region of functional_tests_results.py, so the second to merge needs a rebase.

Version info

  • Merged into: 26.8.1.1807 (included in 26.8 and later)

groeneai and others added 6 commits August 16, 2026 15:05
A hung-check verdict and an observed server death were the same exit code, so
the job side reported both as "Server died". Measured on the flaky-check run
that prompted this: the aggregate said "Failed: 0, Passed: 3872", the server log
showed a clean shutdown with no <Fatal> line and no sanitizer report, and the
harness had located a live server process and attached lldb to it moments before
the verdict was formed.

tests/clickhouse-test collapsed every in-band abort cause into
STOP_TESTING_EXIT_CODE, and ABORTED_RUN_EXIT_CODES appends the synthetic
"Server died" leaf for that code unconditionally. Two other causes had already
been carved out of it for the same reason (GLOBAL_TIME_LIMIT_EXIT_CODE,
MAX_FAILURES_EXIT_CODE), each with a dedicated leaf; the hung check is the third.

Adds HUNG_CHECK_EXIT_CODE and FailureReason.LIVENESS_CHECK_FAILED, reported as
"Server liveness check failed" at FAIL. The four sites that concluded
SERVER_DIED from a failed check_server_liveness probe now use the new reason;
the site that concludes it from a <Fatal> line in stderr is unchanged, and the
one next to it becomes an elif of it, since as two independent ifs a stderr
carrying both signals hit both and the second won, downgrading real fatal
evidence.

The name states the observation rather than a diagnosis. check_server_liveness
catches a bare Exception and clickhouse_execute_http raises on any non-200, so a
server that does respond, with 503 CANNOT_SCHEDULE_TASK for instance, fails the
check; "unresponsive" would overclaim in the same way "died" does.

The stop cause now travels through one locked first-writer-wins helper that all
writers share, and the parent claims the global time limit through it as well.
That replaces global_time_limit_reached, which was a second copy of the same
state: its check-then-set discarded a cause a worker claimed during the window,
and the window is real because the claiming worker then collects stacktraces,
which blocks up to 30 seconds per server process. Hence the ordering at every
detecting site: claim, collect, then set the event. The event goes last because
once it is set the parent waits only five seconds before terminating workers.

A parallel worker on the new path does not call stop_tests(). Its killpg
broadcasts SIGTERM to the whole group including the parent, which would exit 143
before consuming the claimed code, and 143 is itself reported as "Server died" -
so the fix would silently undo itself. The sequential runner owns the main
process and still calls it. This mirrors the --max-failures branch, whose
comment documents the same hazard.

The randomized-settings diagnostics artifact is not saved for the new reason.
The artifact asserts that a test fails under those settings, which a
server-wide stall does not establish, and --diagnose-random-settings replays it.

Consumers of the strings, enumerated by grep rather than by reasoning:
TEST_FAILURE_PATTERNS gains the new reason value, because process_result writes
reason.value into the per-test output and cidb.py matches those strings to build
the cause-filtered history link, so a value matching nothing loses that link for
every witness; SYNTHETIC_TEST_NAMES gains the new leaf, since a run-wide abort
names no single change to revert. check_ci.py's "Server died" reference is
Stress-only and Stress has its own parser, so it is untouched.

"Server liveness check failed" is a new test_name in CIDB, so historical
"Server died" queries will not match it. That separation is the point. The
aggregate status and is_failure() are unchanged, so no job becomes benign,
including bugfix validation, where a hang counts as a reproduction exactly as a
death does, and Fast test, which also passes --hung-check.

Tests: 7 parser cases and 20 runner cases, the latter covering the carrier for
every ordered pair of causes, each of the four decision sites, the string and
artifact consumers, and the exit code the process actually returns. That last
layer is the only one that can observe the killpg corruption, which surfaces as
143 rather than as a wrong reason.
The carrier only helps where it is read. The parent monitor loop checks
stop_testing at the top of an iteration but reaps workers at the bottom, and the
reap is the loop's own exit condition, so a cause claimed in between was never
consumed. With sequential tests in the suite control then fell to the sequential
runner, whose stop arm raised StopTesting with no exit_code and so returned the
default 2 - which the job side reports as "Server died", the exact defect this
branch fixes. Without sequential tests the loop exited normally and the dead
worker's non-zero exitcode set exit code 1, which is deliberately not in
ABORTED_RUN_EXIT_CODES, so neither leaf was emitted.

Both consumers now read the carrier through one helper, falling back to the
default when nothing was claimed - 0 means unset and must never become an exit
code.

Tests for the three sites that were untested. The ConnectionError arm was
reachable by no test, so any one of the three probe-only conclusions could be
reverted with everything still green. The claim on the death path, and its
position before the stacktrace sweep, likewise had no test; asserting the raised
code cannot see it, because the sequential arm raises the default and the default
equals the death code, so the assertion is on the carrier. Both orderings are
driven with a real blocking collection window and the causes swapped, so neither
passes on an implementation that never claims.

test_carrier_uses_the_value_lock pinned lock entry rather than lock scope: an
empty critical section with the read-modify-write outside it passed all three of
its assertions. The carrier is now a property whose getter and setter assert the
lock is held, and a test drives that defect to prove the probe rejects it.

Seven mutation arms, each reddening one named case: dropping exit_code= from the
sequential arm, dropping the unset-carrier fallback, deleting the post-loop
consumer, deleting or moving the death-path claim, moving the liveness claim, and
taking the read-modify-write outside the lock.
The test that pins "an abort site claims its cause before it spends 30s per
process collecting stacktraces" scheduled its interleaving with two independent
sleeps: the competitor thread slept 1s, the stubbed collection slept 4s, and the
only post-run assertion was that the collection had run.

Under the current code that is deterministic. In the direction that gives the
test its value it is not. On a tree where the claim sits below the collection, a
competitor thread that is not scheduled inside those 4s lets the production code
claim first, the competitor loses, and the arm passes on the defect. sleep
releases the GIL, so that is improbable rather than impossible.

The window is now a two-way event handshake with no sleeps in the ordering path.
The collection opens the window, the competitor waits for it, claims, and signals
back; the collection waits for that signal instead of sleeping, so the window is
exactly as long as it needs to be and provably contains the competitor's attempt.
Both events are asserted afterwards - the second one was what was missing. Every
wait is bounded and a missed handshake raises with the name of the handshake that
was missed, so a starved thread fails loudly instead of hanging a CI job.

One new case drives the harness's own failure mode: with no competitor started,
the driver must raise rather than pass or hang. Without it the new waits could be
satisfied vacuously. Both ways of defeating the guard were measured to redden it,
and the three mutations the invariant exists to catch (deleting the death-path
claim, moving it below the collection, moving the liveness claim below its own)
now redden their cases deterministically, three runs out of three.

Also widen the STOP_TESTING_EXIT_CODE docblock, which claimed the code means a
server death was observed. Two live raisers of it involve no death: the
common-database setup failure, and a stop whose cause was never claimed.
Three test-only gaps found by review, all the same shape: an arm whose
interleaving or classification was raced rather than forced.

The sequential side of the is_concurrent split was executed by no test.
_make_suite writes untagged fixtures and is_sequential_test only matches
an --sequential substring or a no-parallel tag, so -j 1 still produced
parallel workers and the "sequential" arm was a second copy of the
parallel one; stop_tests() could be made unconditional with everything
green. The arm now passes --sequential=sleep and asserts the split the
runner prints, with a negative control requiring the parallel
configuration not to satisfy that assertion. A second arm records
stop_tests() calls and pins 1 when sequential and 0 when concurrent,
which the exit code cannot see because both sides exit 5; it asserts the
carrier too, so a count of zero cannot come from never reaching the site.

The in-loop consumer arm keyed on the teardown banner, which is printed
before the raise it was meant to pin, so it passed with that raise
deleted. It now records which call site raised, with the two line numbers
derived from the runner source so a refactor fails loudly instead of
comparing against a stale line. Its ordering is forced by an event that
waits for a worker to signal, the inverse of the existing hidden-once
event, and an unmet handshake raises rather than hanging.

The two arms asserting an ordering against --global_time_limit measured a
budget that also covered database creation and worker startup, so a slow
runner made correct code claim the time limit and exit 3. The test shim
re-arms the deadline on entry to the monitor loop and the arms assert
that it did, so the budget covers the window under test.
…uard

The two arms that pinned "a cause claimed first is not displaced by the global
time limit" reached the deadline end to end, which put process startup - the
multiprocessing manager fork and one fork per worker - inside the budget they
had to outrun. Measured at ~20 ms against a 3-4 s budget, so the margin was
large, but it is not bounded on a shared runner: a slow enough runner makes
correct code claim the time limit first and both arms fail. One of the two was
worse than unbounded - it never reached the deadline at all. Instrumenting
try_claim_stop_cause showed zero time-limit claim attempts across three runs,
because the monitor loop raises in the same iteration the parent's probe sets
stop_testing, so the deadline is not re-evaluated. It could not observe the
ordering it was named for.

Drive the ordering in-process instead, with the deadline and the clock reading
both constants and a handshake putting the worker's claim first on every run.
The retained end-to-end arm keeps its generous budget because it now carries
only the exit code, which is the one layer that can see killpg clobbering it;
it also asserts that the time limit tried and was refused, since that claim's
banner is printed inside the granted branch and a run where the deadline never
expires exits 5 without the two causes ever competing.

The probe's new `not stop_testing.is_set()` guard had no arm: deleting it left
every test green. The exit code cannot see it - under the CAS a second claim
loses either way - so count the calls instead, with the positive control the
count needs to mean anything, and a second control for the --hung-check half of
the condition.

Also replace the em-dash on the one added line in print_c_stacktraces's
docstring with a plain hyphen.
The end-to-end arm for "an expired time limit does not steal a cause the
worker already recorded" had to make the run outlast a deadline to reach
the interleaving, which put the manager and worker forks inside the same
budget. Fork latency on a shared runner is unbounded, so the parent could
legitimately claim the time limit first and the arm would fail on correct
code. Both halves of what it asserted are already pinned by arms that own
their clock: the ordering by the in-process handshake, the exit code by
six other end-to-end arms. Removing it also retires the deadline re-arm
shim and the blocking-collection knob, whose only caller it was.

Moving the liveness claim below the stacktrace sweep still reddens three
cases, so the production defect stays covered.

Co-Authored-By: Claude Opus 4.5 <[email protected]>
@groeneai

Copy link
Copy Markdown
Collaborator Author
Internal second-model review: adjudication log (click to expand)

Pre-publication review by an independent model (engine: codex; 6 review rounds, 12 findings,
all resolved; final round 1 finding).

# Sev Finding Verdict Evidence / action
1 ❌ A stop cause claimed between the parent's check and its reap of the workers is never consumed, so a liveness abort still exits 2 AGREE, fixed @ 7d93a5d Two consumers added through one raise_stop_from_carrier helper: the sequential runner's stop arm, and a post-loop clause covering the check-at-top/reap-at-bottom gap
2 ⚠️ No test reached the changed ConnectionError site, so one of three fixed carriers could be reverted with the suite green AGREE, fixed @ 7d93a5d Three arms added including a negative control; reverting that site alone now reddens two cases
3 ⚠️ The lock-scope oracle pinned lock entry, not lock scope AGREE, fixed @ 7d93a5d Confirmed by mutation: with get_lock(): pass plus the read-modify-write outside it passed all three asserts. Replaced with a probe asserting a lock-held flag in both getter and setter, plus an arm driving that defect through the probe
4 ⚠️ The abort-site interleaving was scheduled with two sleeps, so the mutation-detection direction was probabilistic AGREE, fixed @ 9705661 Two-way event handshake, no sleeps in the ordering path, bounded waits, and a handshake-liveness arm that must raise when no competitor runs
5 ⚠️ The sequential-path arm never ran the sequential path: untagged fixtures plus -j 1 still classify as parallel AGREE, fixed @ 4fbad58 --sequential puts the fixtures on that path (Found 0 parallel tests and 2 sequential tests, asserted), with a negative control proving the assertion discriminates
6 ⚠️ Two arms asserted an ordering they raced for, so correct code could lose and the arm fail AGREE, fixed @ 4fbad58, f56dccf, 9c68562 Reworked in-process against a test-owned clock. The last arm that could still fail on a slow runner was deleted once a mutation proved its coverage redundant
7 ❌ The new probe guard was production behaviour no test could observe: deleting it left the suite green AGREE, fixed @ f56dccf Covered by counting calls to a stubbed probe, with the mandatory positive control and a second control for the flag half
8 💡 Stale and blame-referential comments AGREE, fixed @ 9705661, 9c68562 Swept against the whole diff rather than per round; net comment delta +14 against +31 net code
9 ⚠️ A worker claims the carrier before collecting stack traces but sets the event afterwards, so the parent can start a redundant 65-165s probe inside that window DISAGREE Master's condition is a bare if args.hung_check:, which probes on every iteration including ones where the event is already set. This PR's if args.hung_check and not stop_testing.is_set(): is a strict narrowing of it, so the window is pre-existing and the change only reduces it. The outcome is also correctness-preserving: the carrier is first-writer-wins under its own lock, so the parent's later claim is refused and the worker's cause and exit code survive unchanged. Latency only, bounded, and only inside a run that is already aborting
10 💡 Live-server tests were not executed during the review DISAGREE Review-environment limitation, not a property of the change: those arms target the CI Tests job, which provides a server. Full suite run 5 times at 703 passed / 0 failed, including a shuffled node-id order

Severity: ❌ blocker / ⚠️ major / 💡 nit. DISAGREE verdicts carry recorded evidence and are
terminal per finding. Findings on hunks unchanged by a fix round are auto-dropped.

One thing I noticed and am not raising separately, since it has no user-reachable consequence:
ci/tests/test_hung_check_exit_code.py needs clickhouse on PATH for its 10 end-to-end arms,
so a local run without a server reports them as errors rather than skips. In the CI Tests job a
server is present.

Session id: cron:clickhouse-review-slot-10:20260817-051100

@groeneai

Copy link
Copy Markdown
Collaborator Author
Pre-PR validation gate (click to expand)
# Question Answer
a Deterministic repro? Yes, two pytest commands, no randomization and no timing dependence: python3 -m pytest ci/tests/test_functional_tests_results.py (parser, no server) and python3 -m pytest ci/tests/test_hung_check_exit_code.py (runner, end to end). The end-to-end cases stub check_server_liveness to fail, so the verdict is reached in about a second instead of waiting out the probe's real 65-165 s budget.
b Root cause explained? Yes. tests/clickhouse-test collapses every in-band abort cause into STOP_TESTING_EXIT_CODE = 2; the job side has code 2 in ABORTED_RUN_EXIT_CODES and appends Result("Server died", FAIL) for it unconditionally. So a failed liveness probe and an observed death are the same integer by the time the report is built. Two other causes had already been carved out of code 2 for exactly this reason.
c Fix matches root cause? Yes. The distinction is restored at the layer where it is lost, the exit code, following the precedent of GLOBAL_TIME_LIMIT_EXIT_CODE and MAX_FAILURES_EXIT_CODE. Not a downstream band-aid: the STOP_TESTING_EXIT_CODE comment states that the exit code exists precisely to avoid matching log lines.
d Test intent preserved / new tests added? No existing test is weakened; +48 tests. The two existing narrowness contracts get explicit guards: bugfix validation on code 2 (#105789) and the benign time-limit leaf (#106183).
e Both directions demonstrated? Yes. The same command, same fixtures, same runner binary: pristine master exits 2 and reports Server died; with this change it exits 5 and reports Server liveness check failed. Plus 37 mutation arms, each reddening a named case. The arms that drive a claim/collect race force their interleaving with a two-way event handshake rather than sleeps, so they are deterministic in both directions, and the handshake itself has a test that fails when it goes unmet.
f Fix is general across code paths? Yes. All four sites that conclude SERVER_DIED from a failed probe were enumerated by grep and fixed; leaving any would make the verdict depend on which probe lost the race. Consumers of the reason value and of the leaf string were enumerated the same way, which is how the TEST_FAILURE_PATTERNS dependency was found: the enum values are the pattern strings, so a new value matching nothing loses the cause-filtered CIDB history link.
g Fix generalizes across inputs (params/datatypes/wrappers)? The inputs here are exit codes and reason enums rather than data types. The stop-cause carrier is asserted for every ordered pair of all four codes, in both directions; the parser is asserted for codes 2, 3, 4 and 5 with zero, one and two parsed failures, in and out of bugfix validation.
h Backward compatible? No setting, no serialization format, no SettingsChangesHistory surface. One deliberate observable change: Server liveness check failed is a new test_name in CIDB, so historical Server died queries will not match it. That separation is the goal. The aggregate status and is_failure() are unchanged, verified directly, so no job becomes benign, including Fast test, which also passes --hung-check.
i Invariants and contracts preserved? The carrier's invariant (the first non-zero write survives; 0 means unset) is asserted for every ordered pair, and a test asserts the read and the write both happen with the lock held, driving the empty-critical-section defect through the same probe to show it is rejected. Both places that turn a claim into an exit code are asserted to read the carrier, and to fall back to the default when nothing claimed. The teardown contract is preserved per concurrency mode: only a process that owns the main process broadcasts SIGTERM via stop_tests(), since a parallel worker doing so kills the parent with 143 before it can report the real cause. The parser's UNKNOWN/ERROR demotion and its bugfix-validation carve-out stay inside the single branch, so the new code inherits them rather than bypassing them.

Session id: cron:clickhouse-review-slot-10:20260817-051100

@clickhouse-gh

clickhouse-gh Bot commented Aug 17, 2026 •

Copy link
Copy Markdown
Contributor

Workflow [PR], commit [bfd4885]

Summary: ✅


AI Review

Summary

This PR separates mid-run liveness-probe aborts from the generic Server died path by introducing HUNG_CHECK_EXIT_CODE, propagating it through clickhouse-test and FTResultsProcessor, and updating the affected CI consumers and regression tests. I reviewed the current head diff, the surrounding harness code, and the existing discussion, and I did not find any unresolved correctness or CI-surface issues.

Final Verdict

✅ No blocking issues found.

@groeneai

Copy link
Copy Markdown
Collaborator Author

cc @maxknv @PedroTadim, could you review this? clickhouse-test collapses every in-band abort
cause into STOP_TESTING_EXIT_CODE = 2, and the job side appends a Server died leaf for that
code unconditionally, so a failed --hung-check liveness probe is reported as a death. This adds
HUNG_CHECK_EXIT_CODE = 5 with its own leaf and routes every stop cause through one locked
first-writer-wins carrier, following the existing GLOBAL_TIME_LIMIT_EXIT_CODE precedent.

@PedroTadim PedroTadim added the can be tested Allows running workflows for external contributors label Aug 17, 2026
Comment thread tests/clickhouse-test Resolved
@clickhouse-gh

clickhouse-gh Bot commented Aug 17, 2026 •

Copy link
Copy Markdown
Contributor

Build profile diff (arm_release)

Comparing bfd488597 with master d59f2be34 (stripped binary size, per-symbol sizes and ThinLTO time; compile times per translation unit against the most recent warmup build that recompiled it).

✅ No significant changes.

Binary sizes
Binary Master PR Δ
programs/clickhouse-stripped 700.94 MiB 697.93 MiB -3.01 MiB (-0.43%)

Only the stripped binary is compared: the official master build keeps debug symbols while PR builds strip them, so the other binaries differ by construction.

Compile time of recompiled translation units

7 translation units recompiled, 4 s compile time in total, 7 of them have a recent master baseline.

Job report

groeneai and others added 5 commits August 17, 2026 09:53
The synthetic leaf was renamed to name the observation rather than a
diagnosis, because check_server_liveness also returns False on a non-200
response. Three user-visible messages on the same path still said the
server was not responding or unreachable, so a 503 kept reading as a
server that had stopped answering.

Prose only. The FailureReason value, the exit code and the leaf name are
unchanged, so no CIDB signature and no TEST_FAILURE_PATTERNS token moves.

Co-Authored-By: Claude Fable 5 <[email protected]>
The reap at the bottom of the monitor loop is the loop's exit condition, so
hiding one observation of the event only lands the claim in the check-to-reap
gap when the worker is already dead. A worker that lingers half a second after
setting the event makes correct code take the in-loop consumer instead, and the
two post-loop arms fail on it.

Measured: with the worker lingering 0.5s the arms recorded the in-loop consumer
line; with the join in place they record the post-loop one. An unjoinable
worker now raises naming the timeout rather than passing quietly.

Co-Authored-By: Claude Fable 5 <[email protected]>
The worker abort sites had an arm driving a competitor inside the stacktrace
sweep; the parent's probe site did not, so moving its claim below the sweep left
all 703 tests green. The parent's carrier is created inside do_run_tests, so the
arm captures it from the first claim and hands that same object to the
competitor.

Measured: with the claim below the sweep the arm fails naming the defect in
0.24s; with it above, the arm passes and the sweep's own handshake proves the
competitor ran inside the window.

Also drop the death-discrimination claim from check_server_liveness's docstring.
A non-200 response raises, so False does not establish that the server is gone,
which is the same reason the leaf names the observation.

Co-Authored-By: Claude Fable 5 <[email protected]>
The existing arms pin the helper's own semantics, but each decision site starts
from an empty carrier and writes before anything competes, so replacing any of
the five calls with a plain stop_exit_code.value assignment produced the same
values and left all 704 tests green.

Measured: bypassing all four worker sites, or just the parent's probe site, now
fails naming the offending line. The write's spelling is checked over the whole
file by AST rather than a listed set of lines, with the helper's own write
excluded and a claim-count control so zero direct assignments cannot pass on a
file that stopped claiming altogether.

Co-Authored-By: Claude Fable 5 <[email protected]>
The parent-probe arm started a competitor thread before do_run_tests forked its
workers, and CPython warns that forking a process which has started a thread may
deadlock in the child. The competing claim does not need a thread: the stubbed
sweep already runs inside the window it has to land in, so it claims there.

Deterministic rather than raced, and the arm still fails in 0.24s when the claim
moves below the sweep. The suite's warning count drops by the one this arm added.

Co-Authored-By: Claude Fable 5 <[email protected]>
@clickhouse-gh clickhouse-gh Bot added the manual approve Manual approve required to run CI label Aug 17, 2026
@groeneai

Copy link
Copy Markdown
Collaborator Author

CI finish ledger — bfd4885

CI finished with no live failures: 179 check runs, 0 incomplete, 0 failed, Config Workflow
and Finish Workflow both green.

The result database does hold 4 failure rows for Stress test (arm_release) at this commit,
and they are superseded re-run attempts, not a live red. Grouped by job, attempts
95434160453 (16:33:01Z) and 95495243932 (20:19:49Z) each recorded Check failed plus
Unknown job error, while the surviving attempt 95538890817 (23:13:31Z) recorded
Server successfully started, Test script exit code, No lost s3 keys and
No SharedMergeTree lost forever in clickhouse-server.log all passing, and the check run for
that job is success. A commit SHA does not identify an attempt, so the older rows remain
queryable after the job goes green.

Session id: cron:our-pr-ci-monitor:20260818-000000

@alexey-milovidov

Copy link
Copy Markdown
Member

Ok.

@alexey-milovidov
alexey-milovidov added this pull request to the merge queue Aug 21, 2026
Merged via the queue into ClickHouse:master with commit 783f26c Aug 21, 2026
534 of 540 checks passed
@robot-clickhouse-ci-1 robot-clickhouse-ci-1 added the pr-synced-to-cloud The PR is synced to the cloud repo label Aug 21, 2026
groeneai added a commit to groeneai/ClickHouse that referenced this pull request Aug 21, 2026
Master's ClickHouse#115080 added HUNG_CHECK_EXIT_CODE to ABORTED_RUN_EXIT_CODES and a
per-code leaf selection, which conflicted textually with this branch splitting
the kill-by-signal codes into their own set.

Resolution keeps both: KILLED_BY_SIGNAL_EXIT_CODES holds only the four signal
encodings, and ABORTED_RUN_EXIT_CODES is derived from it plus both in-band
codes, so exit 2 and exit 5 keep their own branches and leaves. The two test
suites were disjoint additions on a shared prefix and are both retained.

Verified after the merge: the four signal encodings take the new branch, while
exit codes 2, 4, 5 and 3 each still take their own master path (no dead branch,
no double handling), and the 23 remaining ci/tests/ failures are byte-identical
to a pristine master tree (no clickhouse binary in PATH).
groeneai added a commit to groeneai/ClickHouse that referenced this pull request Aug 22, 2026
master split FailureReason.SERVER_DIED into SERVER_DIED and
LIVENESS_CHECK_FAILED (ClickHouse#115080), and re-routed three of the four former
SERVER_DIED sites to the new reason. The condition this branch covered
through the SERVER_DIED abort site now arrives as LIVENESS_CHECK_FAILED,
so the SQL dump is added at that site too; a textual union merge would
have left the new path collecting C stacks only, silently dropping the
query_id mapping this branch exists to provide.

Both abort sites claim the stop cause before collecting, per master's
ordering invariant: collection can block ~30s per server process, and a
cause claimed afterwards loses to any cause claimed during it.

Kept this branch's removal of the liveness pre-check in
print_sql_stacktraces. The pre-check probes HTTP while the dump runs over
native TCP, so a failed probe does not predict whether the dump can run,
and get_stacktraces_from_clickhouse is bounded and never raises. Adopted
master's "liveness check failed" wording, which names the observation
rather than diagnosing a death.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

can be tested Allows running workflows for external contributors groeneai-origin-request PR origin: a maintainer pinged or directed groeneai manual approve Manual approve required to run CI pr-ci pr-synced-to-cloud The PR is synced to the cloud repo

Projects

None yet

Development

Successfully merging this pull request may close these issues.

4 participants