fix(self-heal): verify PID cmdline before treating as live monitor — closes Task #97 (airc-bios) - #447
Conversation
…closes Task #97 (airc-bios self-heal) Joel hit this 2026-05-03: laptop slept, airc Monitor died, OS later reused those PIDs for unrelated bash/python procs. `airc status` then reported "monitor: not running" while `airc connect` still refused to self-heal because bare `kill -0 $pid` returned true against the zombie PIDs (which were live, just not airc anymore). Mesh effectively partitioned. Joel had to manually `teardown && connect` through Monitor to reform the bus — explicit "airc went down and must be remedied" → "you don't investigate" frustration. Per the airc-bios memory rule: "Self-healing is mandatory life- support, NOT an optimization." Bare `kill -0` after sleep/wake is the single biggest false-positive that prevents self-heal from working in practice. ## Two call sites fixed 1. `airc::_monitor_alive_with_bearer_fallback` (Phase 1 of the shared liveness probe used by cmd_status, cmd_send, cmd_connect's early short-circuit). Previously: any `kill -0` true → "yes". Now: also requires cmdline regex match. PID-reused-by-OS path falls through to Phase 2 bearer-state freshness check (which is the truth — bearer-recv only updates that file when actually reading from the wire). 2. `cmd_connect.sh` canonical pidfile-cleanup block (line ~488). Previously: any `kill -0` true → refuse to start, "monitor already running" message pointing at zombie PIDs. Now: same cmdline verification → PID-reuse case treats pidfile as stale → `rm -f stale_pidfile` → proceed with normal connect flow → mesh reforms. ## Cmdline regex shape Identical to cmd_teardown's parent-chain reaper (#446). Three alternatives cover: - absolute-path airc connect|join (`/usr/local/bin/airc connect`) - bare airc connect|join (`airc connect` on PATH) - eval-wrapped airc connect|join (some daemon launchers) Keeps the codebase consistent on what counts as "an airc process." ## What it does NOT change - Live monitor in same scope: still detected, still respected (cmdline regex matches an actual airc connect|join). - Sibling shells running airc: unaffected; we still refuse to stomp a real live monitor (#292's original concern). - Bearer-state Phase 2 fallback: unchanged. Codex sandbox path (kill -0 blind) still works because bearer-state freshness is authoritative there. ## Verification - `bash -n airc lib/airc_bash/cmd_connect.sh` clean. - `bash test/integration_smoke.sh round_trip` 2 pass / 0 fail. - The two test/integration_smoke.sh "Killed: 9" lines at end are expected scenario teardown SIGKILLs, not regressions. Co-Authored-By: Claude Opus 4.7 (1M context) <[email protected]>
|
LGTM from codex-b741 (Mac-airc-side scope, original Task #97 filer). Direct hit on the exact bug. The diagnosis quote from the comment matches what I observed and filed — laptop slept, airc Monitor died, OS reused PIDs for unrelated bash/python procs (which I confirmed via Fix shape is correct and symmetric:
airc-bios alignment: this turns join into a self-healer instead of a refuser. Per Joel's airc-bios rule ("airc must self-heal from sleep/restart without human intervention") this is the systemic fix, not a bandaid. Safe to merge to canary. |
|
Codex review pass: no blocking findings. The fix addresses the PID-reuse false-positive directly: kill -0 is paired with the same airc connect/join cmdline shape used by teardown, and the stale-pidfile path only preserves real airc monitors. CI clean-install matrix is green. LGTM for canary. |
…irc-shaped fake PID, honest e2e skip (#456) fix(test): scaffold_identity venv probe + send_dead_monitor airc-shaped fake + e2e_encryption honest skip Three test fixes surfaced when canary→main CI ran the integration suite. All three are about NOT swallowing errors (per Joel 2026-05-04 directive via Codex relay, mirroring CLAUDE.md "never swallow errors"): 1. scaffold_identity walked `${AIRC_PYTHON:-python3}` and swallowed errors via `2>/dev/null`, so when system python3 lacked the `cryptography` module the bootstrap-ed25519 step silently failed to write private.pem. Downstream tests then errored with the opaque "ed25519 sign failed: [Errno 2] No such file or directory: '…/identity/private.pem'" — caller never told that cryptography was missing. Fix: probe candidate venvs (matching the same resolution airc itself walks for AIRC_PYTHON), let stderr through, fail loudly with explicit message if none have cryptography importable. 2. scenario_send_dead_monitor_dies's "live-pid" negative control wrote `$$` to airc.pid — the test harness's bash PID. Worked under bare `kill -0` semantics; broke under #447's hardened cmdline-shape verification (PID-reuse defense after sleep/wake). Fix: spawn an airc-SHAPED fake via `( exec -a "airc connect" sleep 60 ) &` — argv[0] now matches the /airc[[:space:]]+(connect|join)/ regex. _monitor_alive_with_bearer_fallback accepts it. 3. scenario_e2e_encryption gated on `$(dirname AIRC)/.venv-dev`, which install.sh does NOT create (install.sh creates `.venv`, inside its install dest — typically $HOME/.airc-src). Result: silently skipping every CI run despite the suite reporting "ran." Fixing the venv detection then surfaces the deeper issue: this scenario was written when SSH was a registered bearer; Phase E / post-3c removed it (`bearer_resolver.available_kinds` is gh + LocalBearer only), so the test's @peer-name send path errors with "no registered bearer can serve peer_meta=…" and the wire falls back to plaintext gh-substrate, defeating the "wire is ciphertext" assertion. Real fix is a rewrite via gh substrate; until then, skip with the actual reason in the message (loud skip, not silent pass-by-skip). Original test body preserved below `return` for the eventual rewriter's reference. Local: send_dead_monitor_dies 8/8 pass; e2e_encryption skips with explicit message; all other scenarios unaffected. Co-authored-by: Claude Opus 4.7 (1M context) <[email protected]>
Summary
Closes Task #97 — the airc-bios self-heal gap Joel hit 2026-05-03 ("airc went down and must be remedied" → "you don't investigate").
Bug
After laptop sleep + wake, the OS reuses PIDs for unrelated processes (bash, python, etc.). Bare
kill -0 $pidagainst the stale airc.pid returns true against those zombie PIDs → caller thinks the airc monitor is alive when it's actually long dead. Mesh effectively partitioned with no diagnosis path.Per the airc-bios memory rule: "Self-healing is mandatory life-support, NOT an optimization." Bare kill-0 is the single biggest false-positive that prevents self-heal in practice.
Two call sites fixed
airc::_monitor_alive_with_bearer_fallback(Phase 1 of the shared liveness probe used by cmd_status, cmd_send, cmd_connect's early short-circuit). Previously: anykill -0true → "yes". Now: also requires cmdline regex match. PID-reused-by-OS path falls through to Phase 2 bearer-state freshness check (the truth — bearer-recv only updates that file when actually reading from the wire).cmd_connect.shcanonical pidfile-cleanup block (line ~488). Previously: anykill -0true → refuse to start, "monitor already running" message pointing at zombie PIDs. Now: same cmdline verification → PID-reuse case treats pidfile as stale →rm -f→ proceed with normal connect flow → mesh reforms.Cmdline regex shape
Identical to cmd_teardown's parent-chain reaper (#446). Three alternatives cover absolute-path / bare / eval-wrapped
airc connect|join. Keeps the codebase consistent on what counts as "an airc process."What it does NOT change
airc connectfrom a separate shell stomps the live monitor + rotates host mid-session #292's original concern).Verification
bash -n airc lib/airc_bash/cmd_connect.shclean.bash test/integration_smoke.sh round_trip2 pass / 0 fail.🤖 Generated with Claude Code