You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Windows WHPX: run --network <bridge> pulls image before fail-closed rejection #259
On Windows WHPX, a3s-box run --network <bridge> rejects with bridge networking is not supported on Windows only after an image pull (and after network create succeeds). Same first-principles class as #249: unsupported combinations must fail closed before side effects.
Evidence (a3s-box 3.2.5, WHPX host)
a3s-box network create win-probe-net # rc=0, creates bridge network
a3s-box run --rm --network win-probe-net alpine -- true
# stdout: Pulling alpine... [layer pull completes]
# stderr: Error: invalid execution request: bridge networking is not supported on Windows
# rc=1
a3s-box info already reports Bridge networking: unsupported.
Root cause (code)
validate_runtime_options / resolve_execution do not reject Windows bridge early. Rejection lives in managed-record / execution validation after pull (setup_and_boot validates options, then pulls, then builds the managed record).
Expected
Fail closed before pull / Creating box when --network resolves to bridge on Windows.
Clear diagnostic matching info (bridge unsupported).
CLI coverage: command_coverage Windows test asserting no Pulling / no Creating box.
First-principles test cases
WIN-NEG-BRIDGE-01: run --network bridge / named bridge → fail before pull
WIN-NEG-BRIDGE-02: create --network <bridge> → same
Activity
Merge pull request #264 from A3S-Lab/fix/windows-whpx-259-263