You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Found 2026-10-05 by the Qwen3-0.6B fusion work (performance mode, strixhalo). ZAYA1-8B Q4_K_M through llama-server on HRX answers the needle probe (code 7341 hidden in about 1,400 tokens) with "44.", with the private HIP matchers both on and off. Qwen3 0.6B/4B/8B/27B pass the same probe.
Next: run the same probe on the CPU backend and with the F16 GGUF to separate model capability from an HRX long-context issue (CCA conv state across ubatches, attention at more than 1K KV). Teacher-forced top-1 at 1,500 tokens matched HIP-off earlier, which points at model capability or the template rather than kernels.
Update 2026-10-05: two later checks find the needle on ZAYA1-8B Q4_K_M on HRX:
PELICAN-42 at depth 600 and 1500.
Code 7341 at 1484 and 3271 prompt tokens.
Both used llama-server with the chat template, greedy, 3-4 identical requests, and passed on builds with and without the private HIP decode kernels. The failing "44." answer came from the 0.6B fusion worker's probe, which used a different prompt. Next: rerun that exact probe on CPU to see whether it is the prompt or the backend.
The CPU reference is in: the same answer, so this is not the HRX path
The issue's own next step was to run the same probe on the CPU backend to separate model capability from an HRX long-context issue. Done, with the exact model and prompt the HRX runs used.
Harness: ~/wt/loom-q06-run/rep.sh builds the needle (code 7341 at line 44 of a 120-line filler, 1,284 prompt tokens) and records each model's answer.
run
backend
answer
rep-on-zaya1-8b-Q4_K_M
HRX0, private HIP matchers on
"44."
rep-off-zaya1-8b-Q4_K_M
HRX0, matchers off
"44."
CPU, same model and prompt
-ngl 0 -fa on, llama-server f5b7f4a
"44."
rep-both06
HRX0, Qwen3-0.6B
"The secret code is 734"
The CPU run used a byte-identical copy of ~/models/zaya1-8b-Q4_K_M.gguf: sha256 339cac3addcf2b61abdb171a45f29dd11bb986a6741cf9119ae9a615edd44dcc on both hosts. Same prompt (needle.json), same flags (-fa on -c 4096 -np 1).
So ZAYA1-8B answers 44. on the CPU backend too. The miss is not in the HRX kernels or the long-context path - it is the model or the prompt, which the issue already suspected ("Teacher-forced top-1 at 1,500 tokens matched HIP-off earlier"). Qwen3-0.6B finding 7341 on the same harness shows the probe itself is sound.
Closing: no engine change is indicated. Re-open if a CPU run with a different probe finds the needle where HRX misses it.
Activity
bong-water-water-bong commentedon Oct 5, 2026
Update 2026-10-05: two later checks find the needle on ZAYA1-8B Q4_K_M on HRX:
Both used llama-server with the chat template, greedy, 3-4 identical requests, and passed on builds with and without the private HIP decode kernels. The failing "44." answer came from the 0.6B fusion worker's probe, which used a different prompt. Next: rerun that exact probe on CPU to see whether it is the prompt or the backend.
bong-water-water-bong commentedon Oct 6, 2026
The CPU reference is in: the same answer, so this is not the HRX path
The issue's own next step was to run the same probe on the CPU backend to separate model capability from an HRX long-context issue. Done, with the exact model and prompt the HRX runs used.
Harness:
~/wt/loom-q06-run/rep.shbuilds the needle (code 7341 at line 44 of a 120-line filler, 1,284 prompt tokens) and records each model's answer.rep-on-zaya1-8b-Q4_K_M"44."rep-off-zaya1-8b-Q4_K_M"44."-ngl 0 -fa on, llama-serverf5b7f4a"44."rep-both06"The secret code is 734"The CPU run used a byte-identical copy of
~/models/zaya1-8b-Q4_K_M.gguf: sha256339cac3addcf2b61abdb171a45f29dd11bb986a6741cf9119ae9a615edd44dccon both hosts. Same prompt (needle.json), same flags (-fa on -c 4096 -np 1).So ZAYA1-8B answers
44.on the CPU backend too. The miss is not in the HRX kernels or the long-context path - it is the model or the prompt, which the issue already suspected ("Teacher-forced top-1 at 1,500 tokens matched HIP-off earlier"). Qwen3-0.6B finding7341on the same harness shows the probe itself is sound.Closing: no engine change is indicated. Re-open if a CPU run with a different probe finds the needle where HRX misses it.
HRX hardware correctness gate on Strix Halo (hw-gate) (#403)
bump llama.cpp to 2b7960bae: the routed gate/up kernels stay finite a…