Behavioral Mazes

TTL Interface Module

$590.00

16-channel bidirectional TTL interface module for synchronizing operant conditioning chambers with electrophysiology, fiber photometry, calcium imaging, and optogenetics systems.

MazeEngineersby MazeEngineers
Need Help? Visit our Support Center Knowledge base, order lookup, and ticket support
Our Staff are PhD Scientists
Get expert guidance on this product
Louise Corscadden PhD
Louise Corscadden PhD
Director
Schedule a Call Instead

TTL Interface Module for Operant Conditioning Chamber

The TTL (Transistor-Transistor Logic) Interface Module enables precise temporal synchronization between the Maze Engineers Operant Conditioning Chamber and external neuroscience recording and stimulation systems. Essential for researchers conducting simultaneous behavioral and neural measurements.

Key Features

  • 16 Bidirectional I/O Channels — 8 input + 8 output channels, configurable per experiment
  • BNC Connectors — Front-panel BNC ports for direct connection to all major recording equipment
  • Dual Voltage Support — Compatible with both 5V TTL and 3.3V LVTTL logic levels
  • Configurable Logic Polarity — Jumper-selectable active high or active low per channel
  • LED Status Indicators — Per-channel LEDs for real-time visual verification during experiments
  • Optical Isolation — Input channels are optically isolated (500V) to protect chamber electronics
  • Sub-Microsecond Switching — Rise/fall times under 30 ns for precise event timestamping
  • DB-25 Bulk Connector — Rear-panel bulk connector option for single-cable runs to breakout boxes

Compatible Recording Systems

ApplicationCompatible Systems
ElectrophysiologyNeuralynx Digital Lynx SX, Neuropixels, OpenEphys, Plexon OmniPlex
Fiber PhotometryTDT RZ processors, Neurophotometrics FP3002, Doric Lenses
Calcium ImagingInscopix nVista, UCLA Miniscope, custom miniscopes
OptogeneticsLaser controllers, LED drivers, closed-loop stimulation systems
Video TrackingANY-maze, EthoVision XT, DeepLabCut sync

Applications

  • Event Timestamping — Mark lever presses, nose pokes, cue onsets, and reward deliveries in neural recording data with sub-millisecond precision
  • Optogenetic Triggering — Trigger laser or LED stimulation at precise behavioral moments for closed-loop paradigms
  • Multi-Modal Synchronization — Bind behavioral, neural, and video data streams to a common clock signal
  • Fiber Photometry Alignment — Align fluorescence traces (GCaMP, dLight, GRAB sensors) with operant behavioral events
  • IV Self-Administration Studies — Synchronize drug infusion events with concurrent electrophysiology or photometry recordings

Specifications

ParameterValue
Total Channels16 (8 input + 8 output)
Logic Levels5V TTL / 3.3V LVTTL
Output High2.7V min (5V mode) / 2.4V min (3.3V mode)
Output Low0.5V max
Front Connectors16x BNC female
Rear Connector1x DB-25 female
Input IsolationOptical, 500V rated
Switching TimeLess than 30 ns (rise/fall)
Indicators16x per-channel LEDs
Logic PolarityJumper-configurable (active high / active low)
PowerSupplied via operant chamber interface cable

Why Choose Maze Engineers TTL

Unlike competitors that sell separate input and output modules — each requiring additional adapters and breakout boxes — the Maze Engineers TTL Interface Module combines bidirectional I/O, BNC connectivity, and configurable logic in a single unit. This reduces cost, cable clutter, and setup complexity.

Included

  • TTL Interface Module (16-channel)
  • Interface cable for Operant Conditioning Chamber connection
  • Wiring diagrams for common recording system configurations

No questions yet for this product.

Have a question about this product?

The TTL Interface Module connects ConductMaze to electrophysiology and optogenetics recording systems for synchronized behavioral-neural data.

Supported Protocols

Configurable Parameters

Parameter Range Default
Pulse Width 1–1000 ms 10 ms
Output Channels 1–8 4
Event Mapping Configurable CS/US/Response/Reinforcer

Captured Metrics

Metric Description
TTL Events Sent Number of TTL pulses transmitted per session
Event Timing Log Microsecond-precision timestamps for all TTL events

Compatible with Neuralynx, Blackrock Microsystems, OpenEphys, and Sanworks PulsePal.

Want to learn more about ConductMaze automation?

Explore ConductMaze
TTL Interface Module - 16-channel bidirectional BNC interface for operant conditioning chamber
TTL Interface Module
$590.00