{"id":"https:\/\/openalex.org\/W4416940120","doi":"https:\/\/doi.org\/10.1016\/j.ifacsc.2025.100351","title":"Experimental Validation of the ACTIV Multi-Patient Mechanical Ventilation System","display_name":"Experimental Validation of the ACTIV Multi-Patient Mechanical Ventilation System","publication_year":2025,"publication_date":"2025-12-03","ids":{"openalex":"https:\/\/openalex.org\/W4416940120","doi":"https:\/\/doi.org\/10.1016\/j.ifacsc.2025.100351"},"language":"en","primary_location":{"id":"doi:10.1016\/j.ifacsc.2025.100351","is_oa":true,"landing_page_url":"https:\/\/doi.org\/10.1016\/j.ifacsc.2025.100351","pdf_url":null,"source":{"id":"https:\/\/openalex.org\/S2898092079","display_name":"IFAC Journal of Systems and Control","issn_l":"2468-6018","issn":["2468-6018"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https:\/\/openalex.org\/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https:\/\/openalex.org\/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https:\/\/openalex.org\/licenses\/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IFAC Journal of Systems and Control","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https:\/\/doi.org\/10.1016\/j.ifacsc.2025.100351","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https:\/\/openalex.org\/A5045277077","display_name":"Lui Holder-Pearson","orcid":"https:\/\/orcid.org\/0000-0003-0402-3595"},"institutions":[{"id":"https:\/\/openalex.org\/I185492890","display_name":"University of Canterbury","ror":"https:\/\/ror.org\/03y7q9t39","country_code":"NZ","type":"education","lineage":["https:\/\/openalex.org\/I185492890"]}],"countries":["NZ"],"is_corresponding":false,"raw_author_name":"Lui Holder-Pearson","raw_affiliation_strings":["Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand"],"affiliations":[{"raw_affiliation_string":"Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand","institution_ids":["https:\/\/openalex.org\/I185492890"]}]},{"author_position":"middle","author":{"id":"https:\/\/openalex.org\/A5053114029","display_name":"J. Geoffrey Chase","orcid":"https:\/\/orcid.org\/0000-0001-9989-4849"},"institutions":[{"id":"https:\/\/openalex.org\/I185492890","display_name":"University of Canterbury","ror":"https:\/\/ror.org\/03y7q9t39","country_code":"NZ","type":"education","lineage":["https:\/\/openalex.org\/I185492890"]}],"countries":["NZ"],"is_corresponding":true,"raw_author_name":"J. Geoffrey Chase","raw_affiliation_strings":["Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand"],"affiliations":[{"raw_affiliation_string":"Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand","institution_ids":["https:\/\/openalex.org\/I185492890"]}]},{"author_position":"middle","author":{"id":"https:\/\/openalex.org\/A5067335499","display_name":"Yeong Shiong Chiew","orcid":"https:\/\/orcid.org\/0000-0003-3222-2006"},"institutions":[{"id":"https:\/\/openalex.org\/I11662577","display_name":"Monash University Malaysia","ror":"https:\/\/ror.org\/00yncr324","country_code":"MY","type":"education","lineage":["https:\/\/openalex.org\/I11662577"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Yeong Shiong Chiew","raw_affiliation_strings":["Department of Mechanical Engineering, Monash University Malaysia, Malaysia"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Monash University Malaysia, Malaysia","institution_ids":["https:\/\/openalex.org\/I11662577"]}]},{"author_position":"middle","author":{"id":"https:\/\/openalex.org\/A5108093091","display_name":"Geoffrey M. Shaw","orcid":null},"institutions":[{"id":"https:\/\/openalex.org\/I2802773633","display_name":"Christchurch Hospital","ror":"https:\/\/ror.org\/003nvpm64","country_code":"NZ","type":"healthcare","lineage":["https:\/\/openalex.org\/I2802773633","https:\/\/openalex.org\/I4405259026"]},{"id":"https:\/\/openalex.org\/I80281795","display_name":"University of Otago","ror":"https:\/\/ror.org\/01jmxt844","country_code":"NZ","type":"education","lineage":["https:\/\/openalex.org\/I80281795"]}],"countries":["NZ"],"is_corresponding":false,"raw_author_name":"Geoffrey Shaw","raw_affiliation_strings":["Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand","Department of Medicine, University of Otago Christchurch, Christchurch, New Zealand"],"affiliations":[{"raw_affiliation_string":"Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand","institution_ids":["https:\/\/openalex.org\/I2802773633"]},{"raw_affiliation_string":"Department of Medicine, University of Otago Christchurch, Christchurch, New Zealand","institution_ids":["https:\/\/openalex.org\/I80281795"]}]},{"author_position":"middle","author":{"id":"https:\/\/openalex.org\/A5070075671","display_name":"Bernard Lambermont","orcid":"https:\/\/orcid.org\/0000-0001-7915-8748"},"institutions":[{"id":"https:\/\/openalex.org\/I4210134544","display_name":"Centre Hospitalier Universitaire de Li\u00e8ge","ror":"https:\/\/ror.org\/044s61914","country_code":"BE","type":"healthcare","lineage":["https:\/\/openalex.org\/I4210134544"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Bernard Lambermont","raw_affiliation_strings":["Department of Intensive Care, CHU de Liege, Liege, Belgium"],"affiliations":[{"raw_affiliation_string":"Department of Intensive Care, CHU de Liege, Liege, Belgium","institution_ids":["https:\/\/openalex.org\/I4210134544"]}]},{"author_position":"last","author":{"id":"https:\/\/openalex.org\/A5018504920","display_name":"Thomas Desaive","orcid":"https:\/\/orcid.org\/0000-0003-0011-6022"},"institutions":[{"id":"https:\/\/openalex.org\/I157674565","display_name":"University of Li\u00e8ge","ror":"https:\/\/ror.org\/00afp2z80","country_code":"BE","type":"education","lineage":["https:\/\/openalex.org\/I157674565"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Thomas Desaive","raw_affiliation_strings":["GIGA Institute, Liege University, Liege, Belgium"],"affiliations":[{"raw_affiliation_string":"GIGA Institute, Liege University, Liege, Belgium","institution_ids":["https:\/\/openalex.org\/I157674565"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":6,"corresponding_author_ids":["https:\/\/openalex.org\/A5053114029"],"corresponding_institution_ids":["https:\/\/openalex.org\/I185492890"],"apc_list":{"value":3300,"currency":"USD","value_usd":3300},"apc_paid":{"value":3300,"currency":"USD","value_usd":3300},"fwci":0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.5827587,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"35","issue":null,"first_page":"100351","last_page":"100351"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https:\/\/openalex.org\/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9753999710083008,"subfield":{"id":"https:\/\/openalex.org\/subfields\/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https:\/\/openalex.org\/fields\/27","display_name":"Medicine"},"domain":{"id":"https:\/\/openalex.org\/domains\/4","display_name":"Health Sciences"}},"topics":[{"id":"https:\/\/openalex.org\/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9753999710083008,"subfield":{"id":"https:\/\/openalex.org\/subfields\/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https:\/\/openalex.org\/fields\/27","display_name":"Medicine"},"domain":{"id":"https:\/\/openalex.org\/domains\/4","display_name":"Health Sciences"}},{"id":"https:\/\/openalex.org\/T10675","display_name":"Mechanical Circulatory Support Devices","score":0.010200000368058681,"subfield":{"id":"https:\/\/openalex.org\/subfields\/2204","display_name":"Biomedical Engineering"},"field":{"id":"https:\/\/openalex.org\/fields\/22","display_name":"Engineering"},"domain":{"id":"https:\/\/openalex.org\/domains\/3","display_name":"Physical Sciences"}},{"id":"https:\/\/openalex.org\/T11681","display_name":"Nosocomial Infections in ICU","score":0.0027000000700354576,"subfield":{"id":"https:\/\/openalex.org\/subfields\/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https:\/\/openalex.org\/fields\/27","display_name":"Medicine"},"domain":{"id":"https:\/\/openalex.org\/domains\/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https:\/\/openalex.org\/keywords\/mechanical-ventilation","display_name":"Mechanical ventilation","score":0.7638000249862671},{"id":"https:\/\/openalex.org\/keywords\/ventilation","display_name":"Ventilation (architecture)","score":0.6047000288963318},{"id":"https:\/\/openalex.org\/keywords\/acute-respiratory-distress","display_name":"Acute respiratory distress","score":0.46320000290870667},{"id":"https:\/\/openalex.org\/keywords\/tidal-volume","display_name":"Tidal volume","score":0.4047999978065491},{"id":"https:\/\/openalex.org\/keywords\/lung","display_name":"Lung","score":0.3865000009536743},{"id":"https:\/\/openalex.org\/keywords\/pressure-support-ventilation","display_name":"Pressure support ventilation","score":0.374099999666214},{"id":"https:\/\/openalex.org\/keywords\/breathing","display_name":"Breathing","score":0.3698999881744385},{"id":"https:\/\/openalex.org\/keywords\/respiratory-distress","display_name":"Respiratory distress","score":0.3434000015258789}],"concepts":[{"id":"https:\/\/openalex.org\/C2777080012","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q3766250","display_name":"Mechanical ventilation","level":2,"score":0.7638000249862671},{"id":"https:\/\/openalex.org\/C71924100","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q11190","display_name":"Medicine","level":0,"score":0.6316999793052673},{"id":"https:\/\/openalex.org\/C200457457","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6047000288963318},{"id":"https:\/\/openalex.org\/C2909621147","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q344873","display_name":"Acute respiratory distress","level":3,"score":0.46320000290870667},{"id":"https:\/\/openalex.org\/C177713679","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q679690","display_name":"Intensive care medicine","level":1,"score":0.4133000075817108},{"id":"https:\/\/openalex.org\/C2777257755","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q3493813","display_name":"Tidal volume","level":3,"score":0.4047999978065491},{"id":"https:\/\/openalex.org\/C41008148","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q21198","display_name":"Computer science","level":0,"score":0.3905999958515167},{"id":"https:\/\/openalex.org\/C2777714996","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q7886","display_name":"Lung","level":2,"score":0.3865000009536743},{"id":"https:\/\/openalex.org\/C2780368197","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q7241738","display_name":"Pressure support ventilation","level":3,"score":0.374099999666214},{"id":"https:\/\/openalex.org\/C39300077","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q9530","display_name":"Breathing","level":2,"score":0.3698999881744385},{"id":"https:\/\/openalex.org\/C44154836","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q45045","display_name":"Simulation","level":1,"score":0.34709998965263367},{"id":"https:\/\/openalex.org\/C141983124","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q188008","display_name":"Respiratory distress","level":2,"score":0.3434000015258789},{"id":"https:\/\/openalex.org\/C2987404301","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q679690","display_name":"Intensive care","level":2,"score":0.33399999141693115},{"id":"https:\/\/openalex.org\/C2778917391","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q352381","display_name":"Positive end-expiratory pressure","level":3,"score":0.3149000108242035},{"id":"https:\/\/openalex.org\/C136229726","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3084000051021576},{"id":"https:\/\/openalex.org\/C200601418","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q2193887","display_name":"Reliability engineering","level":1,"score":0.30720001459121704},{"id":"https:\/\/openalex.org\/C2776902269","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.30070000886917114},{"id":"https:\/\/openalex.org\/C2777387402","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q545991","display_name":"Artificial ventilation","level":4,"score":0.2840999960899353},{"id":"https:\/\/openalex.org\/C21200559","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.2791999876499176},{"id":"https:\/\/openalex.org\/C42219234","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q131130","display_name":"Anesthesia","level":1,"score":0.2761000096797943},{"id":"https:\/\/openalex.org\/C27101514","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q206120","display_name":"Lung volumes","level":3,"score":0.27239999175071716},{"id":"https:\/\/openalex.org\/C175079658","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.2700999975204468},{"id":"https:\/\/openalex.org\/C168031717","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q1530280","display_name":"Balance (ability)","level":2,"score":0.2685000002384186},{"id":"https:\/\/openalex.org\/C534529494","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q7891","display_name":"Respiratory system","level":2,"score":0.2624000012874603},{"id":"https:\/\/openalex.org\/C3018642899","wikidata":"https:\/\/www.wikidata.org\/wiki\/Q813243","display_name":"Mechanical ventilator","level":3,"score":0.2567000091075897}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016\/j.ifacsc.2025.100351","is_oa":true,"landing_page_url":"https:\/\/doi.org\/10.1016\/j.ifacsc.2025.100351","pdf_url":null,"source":{"id":"https:\/\/openalex.org\/S2898092079","display_name":"IFAC Journal of Systems and Control","issn_l":"2468-6018","issn":["2468-6018"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https:\/\/openalex.org\/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https:\/\/openalex.org\/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https:\/\/openalex.org\/licenses\/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IFAC Journal of Systems and Control","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1016\/j.ifacsc.2025.100351","is_oa":true,"landing_page_url":"https:\/\/doi.org\/10.1016\/j.ifacsc.2025.100351","pdf_url":null,"source":{"id":"https:\/\/openalex.org\/S2898092079","display_name":"IFAC Journal of Systems and Control","issn_l":"2468-6018","issn":["2468-6018"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https:\/\/openalex.org\/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https:\/\/openalex.org\/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https:\/\/openalex.org\/licenses\/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IFAC Journal of Systems and Control","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https:\/\/openalex.org\/W310083883","https:\/\/openalex.org\/W1994788102","https:\/\/openalex.org\/W2058415022","https:\/\/openalex.org\/W2133076568","https:\/\/openalex.org\/W2153745341","https:\/\/openalex.org\/W2163532127","https:\/\/openalex.org\/W2179025852","https:\/\/openalex.org\/W2296132090","https:\/\/openalex.org\/W2901156453","https:\/\/openalex.org\/W2944722606","https:\/\/openalex.org\/W3012762625","https:\/\/openalex.org\/W3013604172","https:\/\/openalex.org\/W3016335790","https:\/\/openalex.org\/W3016572511","https:\/\/openalex.org\/W3019761783","https:\/\/openalex.org\/W3033229640","https:\/\/openalex.org\/W3035077030","https:\/\/openalex.org\/W3036709566","https:\/\/openalex.org\/W3039399953","https:\/\/openalex.org\/W3039912989","https:\/\/openalex.org\/W3046722223","https:\/\/openalex.org\/W3089226957","https:\/\/openalex.org\/W3096704753","https:\/\/openalex.org\/W3132990701","https:\/\/openalex.org\/W3164187368","https:\/\/openalex.org\/W3193372937","https:\/\/openalex.org\/W3196321861","https:\/\/openalex.org\/W3196485311","https:\/\/openalex.org\/W4200010877","https:\/\/openalex.org\/W4210914981","https:\/\/openalex.org\/W4293771817","https:\/\/openalex.org\/W4308039412","https:\/\/openalex.org\/W4388590978"],"related_works":[],"abstract_inverted_index":{"Acute":[0],"respiratory":[1,4],"distress":[2],"and":[3,15,34,45,80,112,144,186,198,242,257,298,306],"disease":[5],"often":[6],"require":[7],"patients":[8,65,90,158,273],"be":[9,28,50,128],"treated":[10],"with":[11,159,176,239],"mechanical":[12],"ventilation":[13,154],"(MV)":[14],"thus":[16],"place":[17],"extreme":[18],"demand":[19],"on":[20],"intensive":[21],"care":[22,322],"units":[23],"(ICUs).":[24],"This":[25,134,194],"burden":[26],"can":[27,49],"unsustainably":[29],"high":[30],"in":[31,173,245,323],"some":[32],"periods,":[33],"particularly":[35],"during":[36,224],"pandemics,":[37],"such":[38,149,253],"as":[39,254],"Covid-19.":[40],"In":[41],"low":[42],"resource":[43],"regions":[44],"countries,":[46],"the":[47,95,108,146,225,228,310],"result":[48],"inequity,":[51],"a":[52,150],"problem":[53],"addressable":[54],"via":[55],"simple":[56,99],"technological":[57],"innovation.":[58],"Ventilator":[59],"sharing":[60],"over":[61],"two":[62,132,174,282],"or":[63],"more":[64,218],"has":[66],"been":[67],"proposed":[68],"but":[69],"strongly":[70],"discouraged":[71],"because":[72],"it":[73],"could":[74],"not":[75,222],"treat":[76],"different":[77,161,240,284,294],"patient":[78,83,106,295],"needs":[79],"hindered":[81],"individual":[82,117],"monitoring.":[84],"However,":[85],"all":[86],"these":[87],"approaches":[88],"ventilated":[89],"in-parallel,":[91],"each":[92],"breathing":[93],"at":[94,202,274],"same":[96],"time.":[97],"A":[98,164,264,301],"switching":[100,304],"valve":[101,305],"enables":[102],"series":[103],"breathing,":[104],"one":[105],"after":[107],"other.":[109],"External,":[110],"low-cost,":[111],"reusable":[113,302],"sensor":[114,307],"arrays":[115],"enable":[116],"monitoring,":[118],"while":[119],"low-cost":[120],"adjustable":[121],"pressure":[122,126],"reducing":[123,227],"valves":[124],"allow":[125],"to":[127,141,152,168,293,316,321],"fully":[129,291],"customised":[130],"across":[131,155,281],"patients.":[133],"study":[135],"uses":[136],"an":[137],"experimental":[138],"test":[139,278],"lung":[140,162,220,232,285,296],"experimentally":[142],"demonstrate":[143],"validate":[145],"ability":[147],"of":[148,179,201,230,319],"system":[151,236,267,280,289,308],"balance":[153],"2":[156,183,190,206,272],"simulated":[157],"very":[160,283],"compliances.":[163,286],"method":[165],"is":[166,221,237,268,290],"presented":[167],"achieve":[169],"equal":[170],"tidal":[171],"volumes":[172],"lungs":[175],"differing":[177],"compliances":[178],"0.10":[180],"L":[181,188],"cmH":[182,189,205],"O":[184,191],"\u22121":[185,192],"0.05":[187],".":[193],"goal":[195],"requires":[196],"driving":[197],"end-expiratory":[199],"pressures":[200],"least":[203],"20":[204],"O,":[207],"which":[208],"are":[209,260,309],"clinically":[210],"relatively":[211],"high.":[212],"The":[213,235,288],"approach":[214],"prioritises":[215],"safety,":[216],"ensuring":[217],"compliant":[219],"over-ventilated":[223],"process,":[226],"risk":[229],"ventilator-induced":[231],"injury":[233],"(VILI).":[234],"compatible":[238],"ventilators,":[241],"cost-effectively":[243],"fabricated":[244],"low-resource":[246,324],"settings.":[247],"Strategies":[248],"addressing":[249],"key":[250],"safety":[251],"concerns,":[252],"cross-contamination,":[255],"sterilisation,":[256],"ventilator":[258],"configuration,":[259],"also":[261],"presented.":[262],"\u2022":[263,276,287,300,314],"customisable":[265,292],"control":[266],"validated":[269,279],"for":[270],"ventilating":[271],"once.":[275],"Bench":[277],"mechanics":[297],"needs.":[299],"active":[303,312],"only":[311],"components.":[313],"Potential":[315],"improve":[317],"equity":[318],"access":[320],"areas.":[325]},"counts_by_year":[],"updated_date":"2026-03-07T16:01:11.037858","created_date":"2025-12-03T00:00:00"}