{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T08:51:36Z","timestamp":1769158296305,"version":"3.49.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2005,8,1]],"date-time":"2005-08-01T00:00:00Z","timestamp":1122854400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med. Biol. Eng. Comput."],"published-print":{"date-parts":[[2005,8]]},"DOI":"10.1007\/bf02344737","type":"journal-article","created":{"date-parts":[[2006,3,15]],"date-time":"2006-03-15T06:57:12Z","timestamp":1142405832000},"page":"535-540","source":"Crossref","is-referenced-by-count":24,"title":["Implantable device for long-term electrical stimulation of denervated muscles in rabbits"],"prefix":"10.1007","volume":"43","author":[{"given":"H.","family":"Lanm\u00fcller","sequence":"first","affiliation":[]},{"given":"Z.","family":"Ashley","sequence":"additional","affiliation":[]},{"given":"E.","family":"Unger","sequence":"additional","affiliation":[]},{"given":"H.","family":"Sutherland","sequence":"additional","affiliation":[]},{"given":"M.","family":"Reichel","sequence":"additional","affiliation":[]},{"given":"M.","family":"Russold","sequence":"additional","affiliation":[]},{"given":"J.","family":"Jarvis","sequence":"additional","affiliation":[]},{"given":"W.","family":"Mayr","sequence":"additional","affiliation":[]},{"given":"S.","family":"Salmons","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"BF02344737_CR1","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1113\/jphysiol.1991.sp018749","volume":"441","author":"W. S. Amood Al","year":"1991","unstructured":"Al Amood, W. S., Lewis, D. M., andSchmalbruch, H. (1991): \u2018Effects of chronic electrical stimulation on contractile properties of long-term denervated rat skeletal muscle\u2019,J. Physiol.,441, pp. 243\u2013256","journal-title":"J. Physiol."},{"key":"BF02344737_CR2","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1111\/j.1525-1594.2005.29037.x","volume":"29","author":"Z. Ashley","year":"2005","unstructured":"Ashley, Z., Sutherland, H., Lanmuller, H., Unger, E., Mayr, W., Kern, H., Jarvis, J. C., andSalmons, S. (2005): \u2018Determination of the chronaxie and rheobase of denervated limb muscles in conscious rabbits\u2019,Artif. Org.,29, pp. 212\u2013215","journal-title":"Artif. Org."},{"key":"BF02344737_CR3","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/BF02510747","volume":"36","author":"R. G. Dennis","year":"1998","unstructured":"Dennis, R. G. (1998): \u2018Bipolar implantable stimulator for long-term denervated-muscle experiments\u2019,Med. Biol. Eng. Comput.,36, pp. 225\u2013228","journal-title":"Med. Biol. Eng. Comput."},{"key":"BF02344737_CR4","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/S1350-4533(02)00193-5","volume":"25","author":"R. G. Dennis","year":"2003","unstructured":"Dennis, R. G., Dow, D. E. andFaulkner, J. A. (2003): \u2018An implantable device for stimulation of denervated muscles in rats\u2019,Med. Eng. Phys.,25, pp. 239\u2013253","journal-title":"Med. Eng. Phys."},{"key":"BF02344737_CR5","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1113\/jphysiol.1988.sp017226","volume":"402","author":"L. Gorza","year":"1988","unstructured":"Gorza, L., Gundersen, K., L\u00f8mo, T., Schiaffino, S. andWestgaard, R. H. (1988). \u2018Slow-to-fast transformation of denervated soleus muscles by chronic high-frequency stimulation in the rat\u2019,J. Physiol.,402, pp. 627\u2013649","journal-title":"J. Physiol."},{"key":"BF02344737_CR6","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1046\/j.1525-1594.2002.06951.x","volume":"26","author":"C. Hofer","year":"2002","unstructured":"Hofer, C., Mayr, W., St\u00f6hr, H., Unger, E., andKern, H. (2002): \u2018A stimulator for functional activation of denervated muscles\u2019,Artif. Org.,26, pp. 276\u2013279","journal-title":"Artif. Org."},{"key":"BF02344737_CR7","volume-title":"Neuroprosthetics: theory and practice","year":"2003","unstructured":"Horch, K. W., andDhillon, G. (Eds) (2003): \u2018Neuroprosthetics: theory and practice\u2019 (World Scientific Publishing Co., River Edge, NJ, 2003)"},{"key":"BF02344737_CR8","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1046\/j.1525-1594.1999.06376.x","volume":"23","author":"H. Kern","year":"1999","unstructured":"Kern, H., Hofer, C., Strohhofer, M., Mayr, W., Richter, W., andSt\u00f6hr, H. (1999): \u2018Standing up with denervated muscles in humans using functional electrical stimulation\u2019,Artif. Org.,23, pp. 447\u2013452","journal-title":"Artif. Org."},{"key":"BF02344737_CR9","first-page":"293","volume":"12","author":"H. Kern","year":"2002","unstructured":"Kern, H., Hofer, C., M\u00f6dlin, M., Forstner, C., Mayr, W., andRichter, W. (2002a): \u2018Functional electrical stimulation of longterm denervated muscles in humans: clinical observations and laboratory findings\u2019,Basic Appl. Myol.,12, pp. 293\u2013301","journal-title":"Basic Appl. Myol."},{"key":"BF02344737_CR10","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1046\/j.1525-1594.2002.06933.x","volume":"26","author":"H. Kern","year":"2002","unstructured":"Kern, H., Hofer, C., M\u00f6dlin, M., Forstner, C., Raschka-H\u00f6ger, D., Mayr, W., andSt\u00f6hr, H. (2002b): \u2018Denervated muscles in humans: limitations and problems of currently used functional electrical stimulation training protocols\u2019,Artif. Org.,26, pp. 216\u2013218","journal-title":"Artif. Org."},{"key":"BF02344737_CR11","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1002\/mus.20149","volume":"31","author":"H. Kern","year":"2004","unstructured":"Kern, H., Salmons, S., Mayr, W., Rossini, K., andCarraro, U. (2004): \u2018Recovery of long-term denervated human muscles induced by electrical stimulation\u2019,Muscle Nerve,31, pp. 98\u2013101","journal-title":"Muscle Nerve"},{"key":"BF02344737_CR12","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1046\/j.1525-1594.1999.06258.x","volume":"23","author":"H. Lanm\u00fcller","year":"1999","unstructured":"Lanm\u00fcller, H., Sauermann, S., Unger, E., Schnetz, G., Mayr, W., Bijak, M., andGirsch, W. (1999): \u2018Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle\u2019,Artif. Org.,23, pp. 352\u2013359","journal-title":"Artif. Org."},{"key":"BF02344737_CR13","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/S1350-4533(01)00014-5","volume":"23","author":"W. Mayr","year":"2001","unstructured":"Mayr, W., Bijak, M., Rafolt, D., Sauermann, S., Unger, E., andLanm\u00fcller, H. (2001): \u2018Basic design and construction of the Vienna FES implants: existing solutions and prospects for new generations of implants\u2019,Med. Eng. Phys.,23, pp. 53\u201360","journal-title":"Med. Eng. Phys."},{"key":"BF02344737_CR14","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/BF00319664","volume":"237","author":"T. Mokrusch","year":"1990","unstructured":"Mokrusch, T., Engelhardt, A., Eichhorn, K. F., Prischenk, G., Prischenk, H., Sack, G., andNeundorfer, B. (1990): \u2018Effects of long-impulse electrical stimulation on atrophy and fibre type composition of chronically denervated fast rabbit muscle\u2019,J. Neurol.,237, pp. 29\u201334","journal-title":"J. Neurol."},{"key":"BF02344737_CR15","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/j.1525-1594.2005.29034.x","volume":"29","author":"S. Salmons","year":"2005","unstructured":"Salmons, S., Ashley, Z., Sutherland, H., Russold, M. F., Li, F., andJarvis, J. C. (2005): \u2018Functional electrical stimulation of denervated muscles: basic issues\u2019,Artif. Org.,29, pp. 199\u2013202","journal-title":"Artif. Org."},{"key":"BF02344737_CR16","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1002\/(SICI)1098-2752(1996)17:11<597::AID-MICR6>3.0.CO;2-M","volume":"17","author":"H. B. Williams","year":"1996","unstructured":"Williams, H. B. (1996): \u2018A clinical pilot study to assess functional return following continuous muscle stimulation after nerve injury and repair in the upper extremity using a completely implantable electrical system\u2019,Microsurgery,17, pp. 597\u2013605","journal-title":"Microsurgery"},{"key":"BF02344737_CR17","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1067\/mhn.2001.118246","volume":"125","author":"D. L. Zealear","year":"2001","unstructured":"Zealear, D. L., Swelstad, M. R., Sant' Anna, G. D., Bannister, R. A., Billante, C. R., Rodriguez, R. J., Garren, K. C., Billante, M. J., andChampney, M. S. (2001): \u2018Determination of the optimal conditions for laryngeal pacing with the Itrel II implantable stimulator\u2019,Otolaryngol. Head Neck Surg.,125, pp. 183\u2013192","journal-title":"Otolaryngol. Head Neck Surg."}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF02344737.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF02344737\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF02344737","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,15]],"date-time":"2019-05-15T17:27:42Z","timestamp":1557941262000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF02344737"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,8]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2005,8]]}},"alternative-id":["BF02344737"],"URL":"https:\/\/doi.org\/10.1007\/bf02344737","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,8]]}}}